My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-12200
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-12200
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/10/2012 1:34:34 PM
Creation date
5/10/2012 1:31:08 PM
Metadata
Fields
Template:
Building Department
Company Name
EILAND PARK TOWNHOMES
Building Department - Doc Type
Permit
Permit #
11-12200
Building Department - Name
LENNAR HOMES LLC
Address
37607 GEORGINA TER #132
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM 1i00A-08 <br /> _ _� .- .:�.. Code Comp��anc�Checklist � .__ __. <br /> a�• �"�` �� -� Residential Whole Buiidi' � rfo"��'nce Method A- Details '�� � <br /> ADDRESS: PERMIT #: <br /> , FL, <br /> _ _ INFILTRATION REDUCTION COMFUANCE CHECKLIST <br /> __ . .�. �. <br /> COMPONENTS ' SECTION ` REQUIREMENTS FDR EACH PRACTICE CHECK <br /> Exterior Windaws & Doors � N1106.AB.1 1 Maximum; 3 cfm/sq.ft. window area; .5 cfm/sq.ft. door_area._ <br /> Exterior & Adjacent Walls N1106.AB.1.2 Caulk, gasket, weatherstrip ar seal between; windows/daors & <br /> #rames, suROUnding wall; foundation 8� wafl so#e or si11 piate; joints <br /> between exterior wall panels at corners; utility penetrations; <br /> between wall panels & toplbottom plates; between walls and floar. <br /> EXGEPTION: Frame waus where a continuaus infiltration barrier is <br /> installed that extends from, and is sealed ta, the foundation to the <br /> -- - -- — -- _ __-- tap_plate. - --- -- - � <br /> Floors N1106.AB.1.2 Penetrationslopenings > 118" seafed untess backed by truss ar � <br /> joinf inembers. <br /> EXCEPTION: Frame floors where a confinuous infiftration barrier <br /> __ __ , is installed thet is sealed to the perimeter, penetrations and seams. __ <br /> Ceilings N1106.A6.12 8etween watls & ceilings; penetratians of ceiling glane to top floar; <br /> araund shafts, chases, soffits, chimneys, cabinets seated ta <br /> continuous air barrier, gaps in gyp board & fap plate; attic access. <br /> , EXCEPTIOIV: Frame ceilings where a continuous infiltration barrier <br /> is installed that is sealed at the perimeter, at penetrations and , <br /> ' seams. <br /> Recessed Lighting Fixtures N 1106.AB.1.2 Type !C rated with no penetrations, seated; ar Type IC or non-IG <br /> , rated, installed inside a sealed box with 1/2" elearance & 3" from <br /> ; insulation; or Type IC with < 2.0 cfm from conditioned space, <br /> � tested � <br /> :.. ..____.. _ _ ..�.___��.__. <br /> - ----- -- - - <br /> Mufti-sto Houses N1106_AB.1.2 r Air barrier on perimeter of floar cavity_between floors. <br /> _ _.._..._...--- -.. _. -T <br /> Addifional Infiltration r�qts N1106.AB.1.3 � Exhausi fa�s vented to outdoors, dampers; eombustion space ' <br /> � heaters camply with NFPA, have combustion air. j <br /> OTHER PRESCRIPTIVE MEASl1RES {must be met or exceeded by all residences.) <br /> COMPONENTS SECTION REQUIREMENTS i CHECK <br /> _.. ..__._.._..--- - -. _ ___..._. ---.._.._-- -.. ._. -- <br /> Water Heaters N1112,A8.3 � Comply with efficiency requiremer�ts in Table N1112.ABC.3 <br /> � Switch ar clearly marked circuit breaker {electric) or cutoff {gas) , <br /> _ � must be provided. E�cternal or builf-in heat trap required. ; <br /> Swimming Pools & Spas ♦ N1112.AB.2.3 5pas & heated paals musf have covers (except solar heated}, <br /> Non-commercial poflts must have a pump timer. Gas spa & pool <br /> ! heaters must have a rninimum thermal efficiency of T8°lo. <br /> _ � Heat_ pool heaters shall have a minimum CUP of 4.0. ' <br /> 5hower heads ? N11 i2.AB2.4 Water flow must be restricted to no more than 2.5 gallons per <br /> � minute at 80 PSIG. <br /> _. _... _..-- -- ----___ __ - - _. _. — - - � - -- <br /> Air Distribution Systems � N1110.A6 All ducts, fittings, mechanical equipment and plenum chambers <br /> shall be mechanically ettached, sealed, insulated and installed in <br /> accordance with the criteria of Section tV1110.AB. � <br /> Ducts in unconditioned aftics: R-6 min. insulation. �. <br /> , _ _ ___.__. .__.._......--- -- __.. <br /> HVAC Cant�aEs N1107.AB.2 Separate readily accessible manual or automatic thermostat for <br /> each system. _ _ . __ <br /> Insulatian . id1104.AB.1 � Ceilings-Min. R-19. Common walls-frame R-1'f or CBS t2-3 both <br /> N1102.B.1.1 sides. Cammon ceiling & floors R-11. <br /> 5J12/20t 1 8:52 AM EnergyGauge� USA - FlaRes2448 Page S of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.