GENERAL NOTES: <br />THIS BUILDING HAS BEEN DtBIGNED TO CONFORM TO THE 2001 FLORIDA BUILDING CODE <br />RESIDENTIAL AND 2005 SUPPLEMENTS <br />ARKAY ENGINEERING INC: A REGISTERED LICENSED, FLORIDA FROFES61ONAL STRUCTURAL <br />ENGINEERING COMPANY: HAS APPLIED " RATIONAL ANALYSIS" FOR THE STRUCTURAL DESIGN <br />OF THI8 STRUCTURE <br />THE BUILDING ( INCLUDING ALL COMPONENTS AND CLADDINGS SHALL BE DESIGNED FOR THE <br />FOLLOWING SUPERIMPOSED LOADS <br />SLAB: <br />LIVE LOAD$ - 50 P .$.F, <br />DEAD LOADS - 0 P,S.F, <br />ROOF: <br />LIVE LOAD$ (TRUSS TOP CORD) - 20 P.S.F. <br />DEAD LOADS (TRUSS TOP CORD) - 10 P,6,1F, <br />DEAD LOAD (TRUSS BOTTOM CORD) - 10 P.B.F. <br />ASSUMED TRU88 SELF WEIGHT ( DEAD LOAD) - 1 P.B.F. <br />WIND DESIGN A68UMPTIONB: <br />BUILDING EXPOSURE - B <br />BUILDING IMPORTANCE FACTOR ■ 1.0 <br />MEAN ROOF HEIGHT 30' OR LESS <br />HEIGHT 1 EXPOSURE ADJUSTMENTS COEFFICIENT • 1.0 <br />ENCLOSED BUILDING <br />INTERNAL PRE66URE COEFFICIENT " • / - 0.18 <br />SEE WIND SPEED AT BOTTOM RIGHT OF ALL SHEETS <br />CONSTRUCTION TYPE: V <br />SOIL BEARING 1 COMPACTION: <br />THESE PLANS WERE DRAWN BASED UPON AN ALLOWABLE $OIL BEARING CAPACITY OF <br />2000 P.B.F.( MINIMUM ) THE CONTRACTOR / PROPERTY OWNER 18 RESPONSIBLE FOR VERIFYING <br />THAT THE SOIL ON THE 81TE 1$ PROPERLY PREPARED AND COMPACTED SUCH THAT IT CAN <br />SUPPORT A 2000 P.B.F. FOUNDATION LOADING <br />ARKAY ENGINEERING INC: A REGISTERED LICENSED FLORIDA FROFE86IONAL STRUCTURAL <br />ENGINEERING COMPANYi DESIGNED THESE FOUNDATIONS WITHOUT VISITING THE CONSTRUCTION <br />SITE NOR PERFORMING ANY $OIL TESTING <br />ARKAY ENGINEERING INC SHALL NOT BE RESPONSIBLE FOR THE SITE SOIL ABILITY TO SUPPORT <br />THE BUILDING LOADS <br />FOUNDATION 4 SLAB - ON- GRADE NOTES : <br />BUILDING 817E SHALL BE SCRAPED TO REMOVE ALL ORGANIC MATERIALS:, <br />ANY ADDITIONAL FILL PLACED ON THE BUILDING PAD AREA, SHALL BE COMPACTED <br />SUCH THAT IT CAN ADEQUATELY SUPPORT A 2000 P.B.F. FOUNDATION LOADING. BLAB <br />SHALL BE PLACE OVER A 6 MIL VAPOR BARRIER ON CLEAN ADEQUATELY COMPACTED <br />AND TERMITE POISONED SOIL <br />CONCRETE UTILIZED IN THE FOUNDATION AND SLABS SHALL HAVE A MINIMUM 28 DAY <br />COMPRESSIVE STRENGTH OF 3000 P.8.1. <br />REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE <br />WITH A8TMI A -615. LAP SPLICES, WHERE REQUIRED $HALL BE A MINIMUM OF 25" FOR <br />4 5 RE15AR , 30" FOR '6 REBAR 4 35" FOR 0 1 RS5AR <br />PLANS ARE ENGINEERED FOR A MAXIMUM BTEMUJALL HEIGHT OF 4 COURSE$ ( AFTER <br />FINAL 61TE GRADING) THE CONTRACTOR OR BUILDING OWNER $HALL DETERMINE THE <br />EXACT BTEMWALL HEIGHT BABE UPON SITE CONDITIONS PRIOR TO POURING THE FOUNDATION <br />AND CONTACT ARKAY ENGINEERING WHEN MORE: THAN 4 COURSE ARE REQUIRED <br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON SITE <br />FOR THE BUILDING INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND A <br />STRING BTRECTED FROM MARKER TO MARKER '(O VERIFY REQUIRED SET BACKS <br />SOIL TERMITE TREATMENT: <br />TERMITE PROTECTION SHALL BE PROVIDED 13Y REGISTERED TERMITICIDES, INCLUDING PESTICIDES <br />APPLIED TO SOIL, OR WOOD, BATING SYSTEMS, CR OTHER APPROVED PROTECTION LABELED FOR <br />USE AS PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. <br />A CERTIFICATE OF COMPLIANCE" SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED <br />PEST CONTROL COMPANY BEFORE A " CERTIFICATE OF OCCUPANCY WILL BE ISSUED, THE CERTIFICATE <br />SHALL STATE: (PER FBC R320.0 <br />THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />TERMITES. THE TREATMENT 16 INACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA DEPARTMEN <br />OF AGRICULTURE AND CONSUMERS SERVICES <br />1/2" CDX OR 1/16" OSB ROOF SHEATHING <br />IF A REGISTERED TERMITICIDE BAIT SYSTEM 16 TO BE USED FOR SUBTERRANEAN TERMITE PREVENTION <br />SECTION R320.1 THROUGH R320.1.6 DO NOT APPLY, A SIGNED FIVER EYAR CONTRACT FROM THE ISSUE <br />OF THE CERTIFICATE OF OCCUPANCY A68URING INSTALLATION, MAINTENANCE AND MONITORING OF THE <br />BAITING SYSTEM $HALL BE PROVIDED TO THE BUILDING OFFICIAL PRIOR TO THE BLAB POUR. THE SYSTEM <br />MUST BE INSTALLED PRIOR TO FINAL BUILDING APPROVAL ( PER FBC R320.11) <br />INITIAL 601L P0180NIN61 TREATMENT SHALL BE DONE AFTER ALL EXCAVATION <br />BACKFILLING 4 COMPACTION ARE COMPLETE ( PER FBC 320.0,) <br />ANY SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RE- TREATED <br />INCLUDING ANY BOX OR FORMED AREAS ( PER FBC R320.1.2) <br />BOXED AREA IN THE CONCRETE SLAB FOR INSTALLATION OF TRAPS SHALL BE MADE <br />WITH PERMANENT METAL OR PLASTIC FORMS, PERMANENT FORMS MUST BE OF AN <br />ADEQUATE SIZE 4 DEPTH TO ELIMINATE ANY DISTURBANCE OF THE SOIL AFTER THE <br />INITIAL TREATMENT ( PER FBC R320.1.3) <br />A MINIMUM 6 MILL VAPOR BARRIER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL <br />DILUTION IF RAINFALL OCCURS BEFORE VAPOR BARRIER PLACEMENT, RE TREATMENT $HALL <br />BE REQUIRED (PER FBC R320.1.4) <br />ANY CONCRETE OVERPOUR , MORTAR OR STUCCO MATERIALS ALONG THE FOUNDATION <br />PERIMETER MUST BE REMOVED PRIOR TO EXTERIOR BOIL TREATMENT. ( PER FBC R320,1.5) <br />EXTERIOR $OIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE <br />WITHIN 12' OF THE STRUCTURE 81DE WALLS (PER FBC R320.1.60 <br />AN EXTERIOR VERTICAL CHEMICAL BARRIER $HALL BE INSTALLED AFTER CONSTRUCTION 18 <br />COMPLETE ( INCLUDING LANDSCAPING AND IRRIGATION) ANY SOIL DISTURBED AFTER THE <br />VERTICAL BARRIER 16 APPLIED, SHALL BE RETREATED (PER FBC R320.1.6) <br />CONDENSATE AND ROOF DOWN SPOUTS DISCHARGE AT LEAST 12" AWAY FROM THE BUILDING <br />SIDE WALL$ (PER FBC R320.1) <br />AFTER ALL WORK 18 COMPLETE ANY L008E WOOD AND FILL MUST BE REMOVED FROM <br />BELOW AND WITH IN 12" OF THE BUILDING. THIS SHALL INCLUDE ALL GRADE STAKES TUB <br />TRAP BOXES, FORMS, SHORING AND ANY OTHER CELLULOSE CONTAINING MATERIALS <br />PER (FBC R320.8131) <br />THE DISTANCE FROM THE EXTERIOR WALL COVERING ( EXCEPTIONS: PAINT AND DECORATIVE <br />CEMENTITIOUS FINISH LESS THAN B /8" THICK ADHERED DIRECTLY ONTO THE FOUNDATION WALL) <br />AND FINAL EARTH GRADE SHALL NOT BE LESS THAN 6" TO ALLOW FOR INSPECTION FOR FUTURE <br />TERMITE INFESTATIONS (PER F13C R104) <br />EXTERIOR WINDOWS 1 DOORS: <br />ALL EXTERIOR WINDOWS 4 GLASS DOORS OR ENTRANCE DOOR $HALL BE TESTED IN ACCORDANCE WITH <br />ANSI /AMMA/NWWDA 101/182 STANDARD AND BEAR AN AMMA OR WDMA LABEL IDENTIFYING THE MANUFACTURE <br />PERFORMANCE CHARACTERISTICS AND APPROVED PRODUCT TESTING ENTITY <br />ALL MULLIONS AND ADJACENT DOOR/WINDOW ASSEMBLIES $HALL BE TEST OR ENGINEERED TO TRANSFER <br />1.5 TIMES THE DESIGN LOADS TO THE ROUGH OPENING SUBSTRATE <br />INSTALL ALL WINDOWS AND DOOR ASSEMBLIES PER THE MANUFACTURE ANCHORING RECOMMENDATIONS <br />TO ACHIEVE THE DESIGN PRE66URES SPECIFIED <br />ELECTRICAL, PLUMBING, t MECHANICAL: <br />IN ACCORDANCE WITH CHAPTER 411.003 (2) (U OF THE FLORIDA ADMINISTRATIVE CODE: ELECTRICAL <br />PLUMBING AND MECHANICAL SYSTEMS SHALL BE DE8IGNED BY THE RESPECTIVE CONTRACTOR TO <br />MEET ALL APPLICABLE CODES, THE ELECTRICAL, PLUMBING AND MECHANICAL SYSTEMS DRAWN HERON <br />ARE BASE UPON A DESIGN PROVIDED BY THE OWNER TO ADDRESS HIS /HER REQUIREMENTS, <br />ALL ELECTRICAL OUTLETS IN BATHROOMS, KITCHEN, (WITHIN 6' FEET OR SINKS), GARAGE AND AT <br />EXTERIOR LOCATIONS SHALL BE WIRED INTO A GROUND FAULT INTERRUPTER "GFI" CIRCUIT <br />'AFI" CIRCUIT <br />ALL ELECTRICAL OUTLETS IN BEDROOMS 1 FIXTURES $HALL BE WIRED INTO AN ARC -FAULT INTERRUPTER <br />SMOKE DETECTORS SHALL BE PLACE IN EACH BEDROOM AND IN HALL WAY AREAS ADJACENT <br />TO BEDROOM AND OTHER LIVING AREAS <br />GROUND WIRE FORM RE13AR TO ELECTRICAL PANEL PER N.E.C. <br />TRUS3E8: <br />IF TH'v CONTRACTOR , TRU68 MANUFACTURE OR ANY OTHER DE51GN PROFESSIONAL REVISE THE <br />TRUSS SYSTEM LAYOUT FROM THOSE SHOWN ON THESE PLANS ARKAY ENGINEERING, INC 16 <br />REQUIRED TO REVIEW ALL FINAL CONSTRUCTION DOCUMENTS FOR COMPLIANCE WITH THE <br />DESIGN INTENT PRIOR TO COMMENCEMENT OF THE PROJECT <br />SECURE U1ALL TO SLAB WITH <br />1/2 "X5" REDHEAD EXPANSION <br />BOLTS 24" OC <br />SECURE POST TO SLAB WITH SIMPSON <br />ABU44 POST BASE WITH 5/8 "X5" REDHEAD <br />EXPANSION BOLT AND l(o) 16D NAILS IN POST <br />1 <br />SEE ROOF TRUSS PLAN <br />SECURE POST TO BEAM WITH SIMPSON <br />AC4 POST CAP WITH (6) IroD NAILS IN <br />POST AND BEAM <br />2X4 WOOD SUB FASCIA WITH <br />ALUMINUM SOFFIT, FASCIA AND <br />DRIP, AND GUTTER <br />m <br />i <br />I <br />I <br />� <br />I <br />000 <br />000 <br />11^ � Kl <br />:CJ <br />SHEET BOTH SIDES OF WALL WITH <br />1116" 05 SHEATHING NAILED 3" <br />OC ON PLATES AND 6" OC ON <br />STUDS, <br />16 "X12" MONO FOOTING WITH <br />(2) "5 REVAR ON CHAIRS <br />WALL SECTION DETAIL <br />NOT TO 5CAL E <br />5' O" <br />ELECTRICAL FLAN 1/4 _ 1 1 0 11 <br />5' O" <br />I I ROOF EDGE I I <br />_._.._._. ...... ...... ............. ._._-_..i.._._. <br />0 \ I <br />i% \ <br />T <br />T RIDGE I O <br />O i <br />at 3 <br />0 �\q(y�v •— • -- --- — •- -- •— •--- •- - -- -•— - <br />�� O O uj <br />_._ 2 _1 —� — — r — ----- ...... -F• —•— <br />o <br />O I <br />GABLE END <br />PARTIAL ROOF PLAN <br />PANEL EDGE SUPPORT FOR NARROW WIDTH ROOF EDGE <br />PER APA TECHNICAL NOTE R215A, I6" - 24" INCH PANELS <br />DOUBLE PLY CLIP THE SIDE ADJACENT TO THE FULL WIDTH <br />PANEL. NONE REQUIRED AT RIDGE OR HIP. 12" - 16" LUMBER <br />ONLY BLOCKING (2X4) FLAT WISE OR EDGEWISE ON THE 61DE <br />ADJACENT TO THE FULL WIDTH PANEL NONE REQUIRED AT <br />RIDGE OR HIP, 12" OR LESS USE LUMBER ONLY BLOCKING <br />(2X4) FLAT WISE OR EDGEWISE ON BOTH PANEL EDGE$ <br />ZONE ° SO RING SHANK NAILS AT 6' OC AT ALL EDGE$ <br />BD RING $HANK NAILS AT 12' OC INTERMEDIATE <br />ZONE 2Q O3 8D RING SHANK NAILS AT 6" OC, 4 OC AT <br />ROOF EDGES, RIDGE LINES, OR GABLE END WALL <br />NOTE. END JOINTS FOR SHEATHING SHALL BE <br />STAGGERED AND OCCUR OVER A FRAMING <br />MEMBER <br />ROOF SHEATHING NAILING DETAIL <br />NOT TO SCALE <br />THE CLIENT UNDERSTANDS THAT THE DESIGNER CARRIES NO LIABILITY INSURANCE AND THEREFORE <br />AGREES TO HOLD HARMLESS, IDEMNIFY, AND DEFEND DESIGNER FROM ALL CLAIMS, LOSSES AND <br />EXPENSES (INCLUDING REASONABLE ATTORNEY FEES) ARISING OUT OF OR RESULTING FROM THE <br />PROJECT, THE DESIGNER WILL IN GOOD FAITH ATTEMPT TO PROVIDE ERROR FREE CONSTRUCTION <br />DRAWINGS, BUT IN THE EVENT ERRORS OCCUR THE DESIGNER WILL NOT BE LIABLE FOR C08T OF <br />REPAIRS OR DELAY TO THE CONSTRUCTION <br />R -30 INSULATION <br />IN ATTIC AREA _ <br />t <br />NAILED PER ROOF SHEATHING DETAIL <br />ENGINEERED ROOF TRUSSES WITH 8D RS NAILS, USE STEEL PLYCLIPS <br />AND 0 30 FELT WITH SHINGLES, <br />1 2 <br />INSIDE CEILING LINE OF SCISSOR <br />TRUSSES, COVER WITH BEADED <br />VINYL SOFFIT <br />DBL 2 X 12 0 2 PINE BEAM <br />WITH ONE LAYER 1/2" PLY <br />WOOD IN CENTER <br />SCREEN <br />DOUBLE 2X4 "2 COVER SHEATHING <br />SPRUCE TOP PLATE WITH TYVEK HOUSE WRAP <br />\ H L\ SIDING <br />\\ <br />STUDS SPACED 16" OC <br />SINGLE 2X4 P.T. <br />BOTTOM PLATE <br />THESE DRAWINGS ARE THE PROPERTY OF RYMAN CONSTRUCTION OF FLORIDA, <br />INC. AND ANY USE OF SUCH DRAWINGS WITHOUT WRITTEN PERMISSION FROM <br />RYMAN CONSTRUCTION OF FLORIDA, INC. IS PROHIBITED. <br />2x4 CROSS- BRACING m RIDGE <br />I 20' -O" MAX <br />i <br />L4111111 <br />111 <br />Ail <br />E <br />I <br />1�1 <br />D�i <br />SEE TRU88 SYSTEM ENGINEERING DRAWINGS FOR ANY ADDITIONAL <br />BRACING OR CROSS BRACING REQUIREMENTS <br />RE Q, MINIMUM TRU55 BRACING <br />ALUMINUM SCREEN CHANNEL <br />ATTACHED TO POST AND <br />FRAMING <br />4X4 P,T, POST <br />TOP /BOTTOM CHORD GABLE <br />Z END BRACING A 48" O.C. MAX <br />FOR THE FIRST 4 ROWS OF <br />TRUSSES (MIN 2X4 ) <br />c m <br />CONT, BOTTOM CHORD <br />BRACING (1 "x4" MIN,) s <br />10' -0" MAX. <br />ARKAY ENGINEERING INC, <br />STRUC RAL ENGINEERS <br />RICHARD �. KIJDEY QP, . <br />FLC %R;D 1 LICENSE NUMB'E - P. 31296 <br />I HERBY CERTIFY IHAT TI-12SE PLANS AND SPECIFICATIONS <br />WERE PREPARES? BY ME OR 1 -! \DFR MY DIRECT SUPERVISION <br />ARE IN COMPLIANCE WITH rNAPTER 16, SECTION 1609 OF THE <br />FLORIDA BUILDING CODE 2001 FOR 120 MPH (3 SECOND GUST) <br />WIND ZONE - 100 MPH FASTEST SPEED AND THE ENTIRE 2001 <br />FLORIDA BUILDING CODE RESIDENTIAL, AND 2009 SUPPLEMENTS <br />Z�zm <br />m <br />o 0 <br />® t9 &° <br />co!I z 00 <br />> tn <br />p �N <br />z M cin <br />m u , <br />0 m <br />Z � W Ul <br />X <br />W O �a <br />Q A u n� <br />Ly z N <br />r m <br />3L <br />F I <br />Z ul m <br />Q :jW <br />OD LL <br />LL <br />r� <br />c:l • <br />_0 Q� <br />z 0 ) <br />LL <br />3 , 1. <br />Ul �$ ` LU <br />gal <br />ll.l <br />W <br />� <br />J <br />Q <br />d <br />Q <br />Q <br />0 <br />3 <br />r <br />o <br />p Q O <br />O �s� <br />~ LU <br />A <br />ALSO AC ° � <br />T AREA <br />1 6 0 SCQ, FT, <br />20P2 <br />ARKAY <br />