My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-12237
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-12237
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2012 9:28:12 AM
Creation date
5/14/2012 9:28:08 AM
Metadata
Fields
Template:
Building Department
Company Name
MEAJESTIC OAKS
Building Department - Doc Type
Permit
Permit #
11-12237
Building Department - Name
MAJESTIC OAKS
Address
39729 COG HILL LOOP LOT 94
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
APPENDIX 13-D <br /> * TABLE 11B•1 MINIMl1M REQUTAEMEN73 (See Note 1) AII Clfmate 2ones <br /> BUILDWG COMPONENT PERFORMANCE CRITERIA INSTALLE� VALUES: <br /> u-Facror = o.ss u-Factor = , (a S <br /> wndows (see Note 2): SHGC = 0.35 SHGC =, 3 S <br /> %ofCFA<=16� %ofCFA= <br /> Exterior door e Wood or insuiated e: <br /> Wa�ls - Ext and AdJ. (see NMe �: <br /> Frama R•13 R-Value = �? <br /> Mass (see Note 3) J <br /> ' Interiorofwell: R-6 R-Value= <br /> Exterior of weil: R-4 R-Vslue = <br /> Electdc resislanca heat See Note 10 Not allowed <br /> Cei�in s see Notes 3 8 4 R=30 R-Velue = <br /> Floors: Sleb-on-grede Norequirement R-Vetue= <br /> Over uncondiBoned aces see Note 3 R-13 <br /> Hot water systems (storage type) <br /> ElecVic (see Note S�: 40 gal: EF = 0.92 Gallons =� <br /> 50 gal: EF = 0.90 EF = <br /> Gas fired (see Note 6): 40 gal: EF= 0.59 Gatlons= <br /> 50 a1:EF=O.SB EF= <br /> Air conditianin m5 see Note SEEH =13.0 SEER = <br /> Heat pump systems (see Note B) SEER=13.0 SEER= <br /> HSPF=7.7 HSPF- . <br /> Gas tumaces AFUE = 76% AFUE _-.� <br /> OiI fumaces AFUE = 78% AFUE _� <br /> Pro rammabte thermostat see Note 10 Must be insffiIled on ell HVAC stems. Instelled? Yes <br /> Ductwork (see Note 9) Locatlon: <br /> Unwndiboned space' R-6, TESTED Unconditioned space <br /> Condltioned space NA R-Vaiue = <br /> Urnented atGc assemhly per R806.4 with insulation at the roof plane R-42 Test reporf: � /�(J /a <br /> Conditioned space 1 i]�A� A <br /> R-Value = <br /> No test re ort re uired <br /> Air HanNer location: �� <br /> Unconditioned attic' or garage Requires test report Location: <br /> Conditioned space or Test report: <br /> Unvented attic assembi er R806.4 with 1nsula5on at the roof Iane No duG test re uired <br /> (i) Each component preser� in the As-Built home must meet or exceed each of the applica6le performance criferia in order to compty with this code using this meihod; oth- <br /> erwisa Method A complfahce must be used. <br /> (2) Windows and doors qualifying as giazed fenestration areas must comply with both the maximum U-Factor and the maximum SHGC (Solar Heat �ain Coefftcient) criferia <br /> and have a maximum total window area equal to or less than 16% of the conditioned floor area (CFA), othenvise Method A must be used for compliance. Excepttons: i. Ad- <br /> dit(ons of 600 square feet {56 m�) or less may have maximum glass to CFA of 50 percent. 2 Renovations with new windows underZ 2 foot overhang whose lower edge does <br /> nat extend further than 8 feet from the overhang may have tinted giazing or doubie-pane clear glazfng. Replacement skylights installed In renovatlons shall be doubfepaned <br /> or singie paned witfi a diffuser. <br /> (3) R-Values are for insulatfon material oniy as applied in accordance with manufaeturers' instailation instructions. For mass walis, tha "interior of wall" requirement (R-6) <br /> must 6e mst except ff at least 50% of the R-4 fnsulation value required forthe "exterfor of wall" is installed exterior of, or integral to, the wall. <br /> (4) Attic knee walis shall be insulated to same level as ceilings and shall have a positivve means oi maintaining insulation tn place. Such means may inslude rigid insula8on <br /> board or afr barrier sheet materials adequately fastened to the attic sides of knee wali framing materiais. <br /> (5) For other electric storage volumes, minimum Ef = 0.97 -(0.00132 " volume). <br /> (6) For other natural gas storage volumes, minimum EF= 0.67 -(0.0019 * volume). <br /> (� For all conver�ional unfts with capacides greater than 30,000 Btu/hi For 5mail-Duct, High-Velocriy units, Space Constrained units, and units with capac�les less than <br /> 30,000 Btu/hr see Table 13-607A8.32A of the Rodda Building Code, Bufldlnp, or Ta6ie N1107A8.3.2A of the Rorida Bullding Code, ResldentlaL <br /> (8) For all conventlonal units wfth capacitles greaterthan 30,000 BtuTh[ For Small-Duct, High-Velocity unfts, Space Constrained unfts, arid units with capacities less than <br /> 30,000 BtWir see Table 13-607.AB.326 of the Horida Buil�ng Code, Building or Table N1107A8.326 of the Florida Bullding Code, Resldentlal. <br /> (9) Ail ducts and a(r handlers shall be either locaied in condi�oned space or tested by a Class i BERS raterto be "substantially" leak free. °Substar�ially leak free" sfiall mean <br /> distribuUon system air leakage to outdoors no greater than 3 cfm per 100 square feet of condiUoned floor area at a pressure differential of 25 Pasral (0.101n. v�a) across the <br /> enfire air distribution system, Inciuding the manufacturer's a(r handler endosure. Exceptlon: New or replacemer� ducts instalied onto an existing air distribution system as <br /> part of an addition or renovation. Such ducts shall elther be Insulated to R-6 or be installed In condftioned space. <br /> 10) The prohtbitlon on electric resistanca heat and the requtrement for programmable thermostats do not apply to additions, renovations, and new heaiing systems installed <br /> in exisUhg buiidtngs. <br /> TABLE 11 B-2 MINIMUM REQUIREMENTS FOR ALL PACKAGES <br /> COMPONENTS SECTION RE�UIRE(dENTS CHE <br /> 6dertor Jointe 8 Crecks ' N1106A8.12 To be ssk�ed weather ed w othervaise sealed. <br /> E#eriw Windows E Doore N1708.AB.7.1 Max.9 cFMs R window ere ' S cfm/ .ft door area. <br /> Sole & To Plates N1106.AB.12.1 8ole atee end enetaHons h to Ietes of mderbr walls must be seaied. <br /> Recessed Li htln N1106.A8.124 e IC rffied vAlh no enetra9ons altemeGves albw . <br /> Muitlsto Houses N11 AB.12.5 Air berrtx on erimeffir of floor between floora. <br /> Frha� � st Fans N9106A8.1.3 ��� ��� to uncondidoned spece shail have dempers, excepi for combustion devices with Integral <br /> e�aust ductwork. <br /> Water Heeters N1112A8.3 ��mP�y wlth �idency requir�nenffi in Table N1112.ABS Switch or deaAy marked droult breaker electric or cutofl <br /> es must be roNded. 6deme! or builFin heet re ired forverNcel f e risers. <br /> Spas & heated pools must have covere (except solar heflted). Noncommerdal pools must have e pump tSmec Gas <br /> Sviimming Pools & Spas N1112.A82.3.4 spa 4 pool heaters must have minimum thertnal ePficiency of 7696. Heat pump pool heaters shall heve a minimum <br /> COP of 4.0. <br /> Hot Water Pi es N7112.ABS Ineula6on is ired for hot w�er dreul ms ndudin heat recove units . <br /> Shower Heads N1112.AB2.4 Weter flow must be rest�ed to no more than 25 eilone mfnute at 80 st . <br /> HVAC Dud Consfruction, Atl ducts, flt8ngs, mecheNcei equipment and pienum chembers shell be mechanicalty etteched, seeied, msulated <br /> insulation & Instaliation N1110.A8 end instelled in accordence wfth the crtteria of Sectlon N1110.AB. Ducts in affics musi be Insulated to a minfmum of `/ <br /> R-e. <br /> HVAC Controls N7107A6.2 Se erate readll exesslhie menual or autometic thertnosfat for each em. <br /> 13-D.24 2007 FlORIDA BUILDING CODE—BUILDING <br />
The URL can be used to link to this page
Your browser does not support the video tag.