Laserfiche WebLink
FC)RM 'f 9 pQA-08 <br /> ____ Code_ Gompliance Checklist - <br /> Residential`Whol�"'Building Performance Methad A- Details �� <br /> ADDRESS: PERMIT #: <br /> , FL, <br /> WFILTRATItJhI REDl1CTIUN CQMPLIANCE CHECKLIST <br /> _COMPONENTS SECTION ' REQUIREMENTS FOR EACH PRACT(GE ' CHECK <br /> . ._ _----- __--------- ----- ---------- --------- -- --- - - <br /> Exterior Windows & Daors _ N9106.A6.1.1 Maximum:_.3 cfm/sq.fit_window area; .5 cfm/sq_fit. door area. <br /> .. ..._. ._. _.. ---- ----...-------. _.. _. ._.. <br /> Exterior & Adja�ent WaAs N1106.AB.1.2 ; Caulk, gasket, we�thersfrip or seal between: vrindowsldoors & <br /> frames, surrounding wall; foundation & wall sole or sill plate; joinfs <br /> between exterior wall panels at ec�mers; utility penetratians; ; <br /> between wal! p�rtels &�oplbattam pletes; between walls and floor. <br /> EXCEPTION: Frame walis where a cpntinuous infftration barrier is , <br /> ; instailed thaf extends from, and is sealed fa, #he faundation to the ' <br /> - --top_piate.- - --------..._.._..__..._...._..-------- ___._...._..._...- - - - - --._ �_ ._ ._. .. <br /> ---._..._..._..._._. .._. _. ..__.__...._.._....__._.__. <br /> ���o�'S N19D6.AB.1.� Penetrations/apenings > 1l8" seafed uniess backed by truss or � <br /> : joint mernbees. � <br /> EXCEPTION: Frarne floors where a con�inuous infiltration barrisr i <br /> __._...._._.._.._...._._...__._.. _. _. _ is installed that is sealed to Ehe perimeter, penetrations and seams. ' <br /> Ceilings ' N1106.AB.1.2 Between wafls � ceiliC�gs; penetrafions of ceiling piane to top floor; <br /> around shafts, �ha�es, soffits, chimrteys, cabinets sealed to , <br /> , con#inuous air barrier, gaps tn gyp board &#op plate; attic access. <br /> EXCEPTION: Frame ceilings where a con�nuaus infiltration barrier � <br /> � is Instalied that is seated at the perimeter, af penetrations and <br /> i <br /> ----.____..._. _ .._.._._.. .---._.._...._...=---...------ - seams. , <br /> , -- --------._._...------.._...__...__.._._. _. ._ ....... ..... ......_.._..-------- <br /> -- -- - .._..._....__. ..---- ------------._...._....__. _. <br /> Recessed Li.ghting Fiutures � N 19 afi.AB.1.2 1"ype IC rated with no penefrations, sealed; pr Type IC or non-IC � <br /> , rafed, installed inside a sea(ed box with 1/2" elr�arance & 3" from i <br /> insulation; or Type IC with < 2.D cfm from conditioned space, � <br /> ��st�d. � <br /> _ __. ____ ___.___------- ------- -----------.------.—m----._._ _ <br /> __ <br /> _ ,_ _ i_ N1'106.AB.1.2 ___ _ Air bsrrier on perimeter of ftoor ca_v�_between floors__ _ <br /> Additional Infiltration reqts I(�9106.AB.1.3 Exhaust fans vented to t�utdoors, dampers; Combustion space � <br /> heaters camply with NFPA, have cambuskian air. <br /> OTHER PRESCRIPTIVE MEASURES (must be met ar exceeded by all residences.j <br /> COMPflNENTS _ SECTION � REQUIREMENTS CHECK <br /> --------.._.._.. _. _.._ . .---------. .._.. _.. _. _. ..__..___..._.__..__ _. _..._._...._.. . ...----_..._... <br /> �_ .._...____._.._..----..._._....___ ............ ._._. ._._. <br /> UVater Heaters N91'12.AB.3 Cflmply with e�ciency requirements in Taktle tV1112,ABC.3 <br /> Switch or clearly marked circuit breaker (electric) or cutoff �gas) <br /> must be rovided. Extemaf or built-in heat trap required. <br /> --._._._. _._...----- _ .. . _ . ---.._.._..... <br /> Swimming Paols & Spas � N1112.A6.2.3 Spas & heaied pools must have covers (except solar heated). <br /> i Non-commerciaf paols must have a pump timer. Gas spa & pool <br /> heaters must have a minimum thermal efficiency of 78%, <br /> _. ._-.---.._._..._.. - `.. - - _-.__ .-. -- -. - . Heat_pump pool heaters shall_have a minimum COP of 4.0,_ <br /> --- - - - - - - ._ ... _. _._... --- <br /> Shawer heads ; N1112.AB.2.4 Water flow rnusf be restricted to t�o mare fhatt 2'.� gallans per <br /> _. .._...__.. .._.._..._. � _ .._..i._minute at BO PSIG. <br /> _. � --...___...- -------- ____. _._.. - ----.._..--- - - <br /> �tic Distribution 5ysfems � N1110.A6 ; AU ducts, fittings, tnechanical equipm�nf and plenum chambers <br /> � shall [ae mechanically attached, seated, insulated and installed in <br /> � � accardance with the criteria of Section N11 iO.AB. I <br /> __..._.. ..__�____.__.._. ___ ! ; Ducts in unc�nditioned attics: R� min. insulation. <br /> �------...._...------- - --------...-----------..._..-------..._.._....----...._..__._..._._..._.. .._.__..__. ..---- -----------.._.. ..._. .__.._._._...._. <br /> HVAC Controls i N1107.AB.2 ' Separate readily.�ccessible manuaf ac aUtomatic thermostat for <br /> .._.. .---._....__.._._._._..._. ..--- ---- ____� ._--=- stem. .-------...-----._..._______...___._...------ -- ----- <br /> i . _...__ _..__..___.__. .._._. <br /> _ _. .._.. . _ <br /> tnsulation ' Irf1104AB.1 ; Ceilings-Min. R-19. Gommon watls-frame R-11.or CBS a-3 both <br /> I N1 i 02.8.1.1 i sides. Common ceiling & floors R-11. <br /> 5/1212011 1d24 AM EnergyGauge� USA - FlaRes2008 Page S of 5 <br />