My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-12354
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-12354
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/11/2012 12:44:44 PM
Creation date
6/11/2012 12:44:43 PM
Metadata
Fields
Template:
Building Department
Company Name
FIRST BAPTIST CHURCH OF ZEPHYRHILLS
Building Department - Doc Type
Permit
Permit #
11-12354
Building Department - Name
TC FIRST BAPTIST CHURCH OF ZEPHYRHILLS
Address
38300 5TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
: 1 � �� � ` ����/ ����� Date: 8/23/2011 11:25:04AM <br /> ' >r,�,... 3., ..-.;;; �. <br /> ,.�. ,�1��°��E'"Qt31"t - <br /> � f�� a ..�.. ..�.,: .;: <br /> Annual Activity Date: 8/23/2011 9�30:50AM <br /> Zephyrhills Fire Rescue Activity Number' I-113-11-0340 <br /> Fire Prevention Bureau Activity Cause: Periodic <br /> �' 6907 �airy Rd Inspector Name: Kerry Barnett <br /> ; Zephyrhills, FL 33542 Inspector Phone: <br /> Phone:813-780-0041 Status: Fall <br /> Fax: 813-780-0044 <br /> P�: Occupancy Type: Assembly <br /> FIRST BAPTIST CHURCH Property Use: Places of Worship <br /> (000276) Total Violation• 6 <br /> 38300 5TH AVE Corrected Violation� 0 <br /> ZEPHYRHILLS, FL 33542 Hours: 0.50 <br /> 813-782-5574 Total Fees. $ 0.00 <br /> . <br /> ,;� �<:, e.�>. . _ y , , :>,; , , , ,. _ � . <br /> ,. <br /> � '', < .� - � <br /> � . _ _ - <br /> .. .. �.; . .. �,- . <br /> ;-, <br /> . � . <br /> .. . ... . . . <br /> �.�. . <br /> . <br /> z , ,,, , • . _,�.. <br /> . <br /> �� <br /> . i z <br /> : , + � <br /> :S.Y.�':3�..� ' ' ro... � <br /> Ref Number NFPA 1(2�06) Fiorida Fire Prevention (2007) 11 1.5 Electrical Fire Safety <br /> xtension cords shall not be used as a substitute for permanent wiring. <br /> omment: IN THE SANCTUARY - REMOVE WHITE EXTENSION CORD BY ORGAN AND REPLACE WITH CORDED SURGE STRIP <br /> ----- --- --- --- ----- — ----- -- ------- - -- - — -- - - - - <br /> Ref. Number: NFPA101 (2006) Florida Fire Prevention (2007) 4 6.1.2 Authority Having Jurisdiction. <br /> ny requirements that are essential for the safety of building occupants and that are not specifically provided for by this Code shall be determined <br /> � the authority having jurisdiction. <br /> omment: LABEL ALL ELECTRIC, MECHANICAL, AND STORAGE ROOM DOORS AS SUCH. <br /> - --- ----- — ------ -- ----- --- -- -------- - <br /> Ref. Number: NFPA 1(2006) Florida Fire Prevention (2007) 1 12.1 Permits and Approvals. <br /> he AHJ shall be authorized to establish and issue permits, certificates, and approvals pertaining to conditions, operations, or materials hazardous <br /> � life or property pursuant to Section 1 12. <br /> omment: AN ASSEMBLY PERMIT IS REQUIRED FOR THE DINING HALL AND CHAPEL. PERMIT MAY BE OBTAINED FROM THE BUlLDING DEPT. FEE <br /> /ILL BE WAIVED FOR THE CHURCH. <br /> Ref. Number NFPA 1(2006) Florida Fire Prevention (2007) 11 1 5 Electrical Fire Safety <br /> xtension cords shall not be used as a substitute for permanent wiring. � <br /> omment: IN ROOM 407, REMOVE WHITE EXTENSION CORD AND REPIACE WITH CORDED SURGE STRIP <br /> -- --- ---- -- - - - - --- -------- --- ---- --- - ----- - — - — ---- --------- --- — - <br /> Ref. Number NFPA 1(2006) Florida Fire Prevention (2007) 11 1 5 1 Multiplug Adapters. <br /> ultiplug adapters, such as multiplug extension cords, cube adapters, strip plugs, and other devices, shall be listed and used in accordance with <br /> eir listing <br /> omment: REPLACE MULT1-PLUG ADAPTER IN DINING HALL BY COFFEE COUNTER WITH CORDED SURGE STRIP ADAPTER HAS ALREADY HAD <br /> N ELECTRICAL FAULT IN ONE OF THE PLUG INS <br /> ----- ----------------- -- - - --- - - - <br /> - -- — - -- -- - --- -- ---- — --- <br /> Ref. Number• NFPA 96 (20�8) 11 6 14 Cleaning of Exhaust Systems. <br /> fter cleaning or inspection is completed, the exhaust cleaning company and the person performing the work at the location shall provide the <br /> vner of the system with a written report that also specifies areas that were inaccessible or not cleaned. <br /> omment: THERE IS NO CLEANING LABEL ON HOOD INDICATING THE LAST TIME THE HOOD WAS CLEANED BY A CERTIFIED CLEANER. HOOD <br /> -iALL BE CLEANED ANNUALLY THERE IS NOTHING ON FILE THAT THE HOOD HAS BEEN CLEANED WITHIN THE LAST YEAR. HAVE HOOD <br /> LEANED BY COMPANY. <br /> + , . y p.a� : . � : � , _ . . . <br /> ��: a*����I� � " , . ° . <br /> o Pre-existing Outstanding Violation <br /> omments: <br /> NNUAL FIRE SAFETY INSPECTION CONDUCTED SEVERAL VIOLATIONS NOTED THAT WILL BE REQUIRED TO BE CORRECTED B <br /> �E DATE NOTED <br /> �-Inspection to be performed on or before: September 26, 2011 12:00 am <br /> Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.