My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-12387
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-12387
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/11/2012 1:04:17 PM
Creation date
6/11/2012 1:04:15 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
11-12387
Building Department - Name
HELP PROPERTIES LLC
Address
38530 5TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WOOD DECK SYSTEM LIlVIITATIONS: <br /> I. A slip sheet is required with P[y 4 and Ply 6 when vsed as a mechanically fastened base or anchor <br /> sheet. <br /> GENERAL LIlYIITATIONS: <br /> 1. Fire classification is not part of this acceptance, refer to a current Approved Roofmg Materiais <br /> Directory for fire ratings of this product. <br /> 2. Insulation may be installed in multiple layers. The first layer shal] be attached in compliance with <br /> asphalt applied within the EVT range and at a rate of 20-40 IbsJsq., or mechanically attached using <br /> tfie fastening pattem of the top layer <br /> 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved <br /> asphalt, panel size shall be 4' x 4' m�imum. <br /> 4. An overlay and/or recovery board insulation panel is required on all applicaiions over closed cell <br /> foam insulations whett the base sheet is fully mopped. If no recovery board is used the base sheet <br /> shall be apptied nsing spot mopping with approved asphait, 12^ diameter circles, 24" o.c.; or strip <br /> mopped 8" ribbons in three rows, one at each sidelap and one down the centea- of the sheet altowing a <br /> continuous area of ven#ilation. Encirciing of the sp�ips �s not acceptable. A 6" break shall be placed <br /> every 12` in e�h ribbon to allow cross ventilation. Asphaft app��c,ation of either system shall be at a <br /> minimum rate of 12 Ibs./sq. <br /> Note: Spot attached systems shall be limited to a ma�mum design pressare of -45 psf. <br /> 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F'} value of <br /> 275 Ibf., as tested in compliance with Testing A}�lication Standatd TAS 2 O5. If the fastener value, <br /> as field-tested, are below 2751bf. insulation attachment s6a11 not be acceptable. <br /> 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based <br /> on a minimum fastener resistance val� m conjnnetion with the m�imum design value listed within <br /> a specific system. Should the fastener resistance be less than that required, as determined by the <br /> Building Official, a revis� fastener spacing, prepareci, signed and sealed by a Florida Registered <br /> Engineer, Architect, or Registered Roof Consuhant may be submitted. Said revised fastener spacing <br /> shall utilize the withdrawal resistance value taken from Testing Application Standards TAS I OS and <br /> calcuiations in compliance with Raofing Application Standard RAS 117. <br /> 7. Perimeter and corner areas shall compiy with the enhanced uplif} pressure requir�ents of these <br /> areas. Fastener densiries shall be inereased for both insuiation and base sheet as calculated in <br /> compliance with Roofing Appliartion Standerd RAS 117. Caicu[ations prepared, signed and sealed <br /> by a Florida registered pcofessiona� Engineer, Registered Aschibect, or Registered Roof Consultant <br /> (When this limitaiion is spec�ficaHy regerned with�g t�is NOA, General Limi�tion #9 will not be <br /> applicable.) <br /> 8. All attac:hment and sizing of perirneter nai)ers, metal pmfile, and/or flashing termination designs shall <br /> conform with Roofing Application Standard RAS 11 l and applicable wind toad requirements. <br /> 9. The maximum designed pressure limitation fisted shall be applicabie to all roof pressure wnes (i.e. <br /> field, perimeters, and comeis), Neither rahonal �a�ysis, nor extrapolation shall be permitted for <br /> enhanced fastening at enhanced pressure zones (i.e. periu►eters, eactended corners and corners). <br /> (When this. limitation is specific�lty referred witl�in this NOA, General Limitatioo #7 will not be <br /> applicable.) <br /> END OF THIS ACCEPTANCE <br /> NOA No.: 07-1018.14 <br /> �- Eapit�ation Date: 08l22/12 <br /> • Approvai Date: 02/'2I/OS <br /> Page ld of 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.