FORM 1100A-08 <br /> Code Compliance Checklist <br /> Residential Whole Building Performance Method A- Details <br /> ADDRESS: PERMIT #: <br /> , FL, <br /> INFILTRATfON REDUCTION COMPLIANCE CHECKLIST <br /> COMPONENTS _ . SECTION _ RE QUIREMENTS FOR E ACH PRAC _ _ CHECK <br /> Exterior Windows & Doors N1106.AB.1.1 '_ Maximum: .3 cfrrJsq.ft. window area; .5 cfmisq.ft. door area. <br /> Exterior 8� Adjacent Walls N1106.AB.1.2 Cauik, gasket, weatherstrip or seal between: windows/doors & <br /> frames, surrc�unding waH; foundation 8� wall sole or sill plate; joints <br /> between exterior wall panels at comers; utilihr penetrations; <br /> between wall panels & top/battom plates; between walis and floor. <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is <br /> instaBed thaf e�ctends ftom, and is sealed to, the foundation to the <br /> t op plate. _ <br /> Floors N1106.A6.1.2 Penetratipns/ope�ings > 1/8" sea[ed unless backed by truss or <br /> joint members. <br /> EXCEPTION: Frame floors where a continuous infiltration barrier <br /> is in stalled tha is sealed to t he perim eter, penet and sea <br /> Ceilings N1106.A6.1.2 Between walls 8� ceilings; penetrations of ceiGng pla�e to top floor; <br /> around shafts, chases, so�ts, chimneys, cabinets sealed to <br /> continuous air barrier, gaps in gyp board 8� top plate; attic access. <br /> EXCEPTION: Frame ceilings where a continuous irifiltra6on barrier <br /> is installed that is sealed at the perimeter, at penetrations and <br /> seams. - - <br /> Recessed LigMing Fixtures N7106.A6.12 Type IC rated w+th no peneVations, seeled; or Type IC or non-IC <br /> rated, installed inside a sealed box with 1/2" ctearance & 3" from <br /> � insulation; or Type IC with < 2.0 cFm from conditio�d space, <br /> tested. _. __ - <br /> Multi-sto Houses N11 Air bamier on perimeter of floor cavity between floors. <br /> Additional Infiltration reqts N1106.AB.1.3 Exhaust fans vented to outdoors, dampers; combustion space <br /> heaters comply with NFPA, have combustion air. <br /> OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) <br /> COMPONENTS SECTlON REQWREM�NTS _ _ _ _ CHECK <br /> Water Heaters N1112.AB.3 Comply witM efficiency requirements in Table N1112.ABC.3 <br /> � Switch or clearly marked circuit breaker (eledric) or cutoff (gas) <br /> __ _ must be pravideci. Extemal o� built-in heat trap required. . <br /> Swimming Pools 8� Spas N1912.A6.2.3 Spas & heated pools must have covers (except solar heated). <br /> ' Naii-commerciat pools must have a pump timer. Gas spa 8� pool <br /> heaters must have a minimum thermal efficiency of 78%. � <br /> Heat pump heaters shaA have a minimum COP of 4.0 '_ <br /> Shower heads N1112.AB.2.4 Water flow must be resVicted to no more than 2.5 gallons per � <br /> minute at 80 PS1G _ <br /> Air Systems N1110.AB Alf ducts, fittings, mechanical equipment and plenum chambers <br /> shall be mechaniCaHy attached, sealed, insutated and installed in <br /> accordance wiih the criteria vf Sec�ion N1110.A6. <br /> Ducts in uncanditioned attics: R-6 min. insulation. _ ' <br /> HVAC Gontrols N1107.A8.2 Separate readily accessible manual or automat� thermostat for <br /> each sYStem. _ --- . . <br /> tnsulatwn N1104.AB.1 Ceilings-Min. R-19. Common walls-ftame R-11 or CBS R-3 both <br /> N1102.B_1 1 sides. Common ceiling & floors R-11. <br /> 9t21Z011 8:55 AM EnergyGauge� USA - FlaRes2008 Page 5 of 5 <br />