My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-12441
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-12441
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/12/2012 11:53:09 AM
Creation date
6/12/2012 11:53:06 AM
Metadata
Fields
Template:
Building Department
Company Name
EILAND PARK TOWNHOMES
Building Department - Doc Type
Permit
Permit #
11-12441
Building Department - Name
LENNAR HOMES
Address
37631 GEORGINA TER #128
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 &2 Family Dwelling <br /> Plan Review Comments <br /> 1. I� I�.I; �hall h� a minimum c�f 8'° abo� e the r�oad elevation and a engineered tit� plan. <br /> ?. I.�ts shall be gr�aded tc� compl}� � ith R401.3 of�the F.B.C.. <br /> 3. ('c�mpaction test requii ii��4" c�r mc�re of�fill dirt is brought in at an} cme plac�. <br /> 4. Z�ie ��� sur� ey required befare pounng c�ncrete <br /> 5. Dri�°e���ati�s require a R.O.W. use pennit. <br /> fi. All setbacks s11a11 bc met. <br /> i. All property markers shall he unco� ered and marked at time of hrst inspection. <br /> K. All A D.A. requirements shall be met. <br /> � Nu electnc. plumb�ng, mechanical, or fram�ng shall be co� ered «��th�ut an inspection and <br /> ap�rc���al first. <br /> 1 U. All (�arages shall cc�mpl�� ����th sect�on R3Q9.2 of the F.B C' (Fire Separation}. <br /> 11. Ap�liances shall not be �nstalled in a location where sub�ect to mechan�ral damage unless <br /> protected b}� appmved barriers. M303.4 of the F.B.C' <br /> 1? Water heaters shall comply ��ith sect�un P607.� of the .F.B.C' <br /> 13. I�c�uilc�ation supports loi A/C' units shall be raised at least 3" aha��e fiiiished gr•ade. I�� 13(l8. I <br /> 14. Retu� air In all bedr<�oms. F.B.0 M 1620.4 <br /> I S. Smoke detectars are ta be �nstalled �n accordance with R3l 3.1 of the F.B C. <br /> 16. All g(az�ng requirements are to be in accordance ���th R308.4 of the F.B C'. <br /> 17. All means ��f egress are to be in accordance with R31 ] of the F.B.C. <br /> 18. "Green gypsum board" shall not be used as a backer in sho���ers or tubs. R702.4.2 F.E3.C. <br /> I9. Cc�mh�nation-t��c AFCI breakers are required at all lc�cat�ons requ�ring a AFCI type breaker. <br /> 2O. C'arhun monox�de alar ���ill be reyu�l �n ne��� constructi�n that uses fossil-burning heating <br /> or ap��l�ances �i an attached garage. Theti� shall be installed �n accc�rdance with the F.B.C. <br /> 21. All plumbing. mechanical. and clectncal shall he separate from unit to unit. This includes all <br /> underground plumb�ng and electr�c. <br /> 22. All 2OOR N.E.C' C'odes «ill be enforced. <br /> 23 �I��mper- Res�stant Receptacles in accordance ����th 406.11 of the 20UK N E.0 <br /> ?�? In aece�rdanee ���it1� the I_.anc� De� elc�pment C'c�de, lots shall bc sc�ddec3 bef�re final at least 1(� <br /> fect are�und the structure. <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code (2007) <br /> R.O.W.-Right Of Way <br /> A.D.A.- Americans with Disabilities Act <br /> N.E.C.- National Electric Code <br />
The URL can be used to link to this page
Your browser does not support the video tag.