Laserfiche WebLink
FORM 1100A-08 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Community Affairs Residential Performance Method A <br /> Project Name: 1396 9 11 Builder Name' IENNAR HOMES <br /> Sueet 37G35 GEaR 6► N A T�R.2 Permit Otfice: G' �'rc� o F Z� y�. N, � <br /> Ciiy. State. ZiP' . FL , y�� ��ieN i u.S � F� 33�H2 Permit Number � <br /> Uwner: IENNA H ES Jurisdiction: <br /> Design Locatio�: FL. Tampa <br /> t. New construction or existi�g New (From Plans) 9. Wall Types (1680.0 sqft.) Insulation Area <br /> 2. Single family or mulGple famity Multi-family a. Concrele Block - Int Insul, Common R=4.1 933.33 ft <br /> b. Concrete Bbck - I[tt Insul, Exterior R=10.1 522.87 ft' <br /> 3. Number of urrits, if muttiple family 1 c. Frame - Wood, AdjaceM R=11.0 224.00 ft' <br /> 4. Number of Bedrooms 2 d. WA R° � <br /> 5. Is this a worst case? Yes 10. Ceiling Types (1400.0 sqft.) Insulatian Area <br /> a. Under Attic (Vented) R=30.0 1400.00 It� <br /> 6. COnditicNted floor area {ftT) 1� b. NlA R= ft' <br /> 7�ndows(140 1 sqft.) DescriPtion Area c_ N/A �= ft' <br /> a. U-Fador: Dbl, U=0.55 ��� R' � � p � s <br /> SHGC: SHGC=0.32 <br /> b. U-Fador Dbl, U=0.52 32.00 ft' e• Sup: Attic Ret: At1ic AH: Interior Sup. R= 6, 290 fN <br /> SHGC: SHGC=0.30 12. Cooling systema <br /> c. U-Fador. Dbl, U=0.51 32.00 ft' a. CenVal Unit Cap: 23.6 kBtulhr <br /> SHGC: SHGC=0.33 SEER:15 <br /> d. U-Fector Obl, defauR � 2 � K 13. NeatinB systems <br /> SHGC: C1ear, default a. ElecVic Heat Pump Cap� 22.4 kBtuThr <br /> e. U-Fador• N!A ft� HSPF:9 <br /> SHGC: <br /> 14. Hot water systems <br /> S. Floor Types t�aoa.o sqft.) Insulalion Area a. E�� Cap: 4Q gallons <br /> a Slab-On-Grade Edge Insulation R=0.0 1400.00 ft' EF. 0.92 <br /> b. N/A R= h' b. Conservatan features <br /> C. N/A R° ft None <br /> 15. Credks P� <br /> Total As-Built Modified Loads: 22.78 <br /> G1ass/FloorArea: 0.10d Total BaselinQ Loads: 3i.3fi PASS <br /> �tttE sr <br /> I hereby certify that the plans and speafications covered by Review of the plans and O f A��, <br /> this ca�ulation are in compliance with the Florida Energy speciflcations covered by this �. ,,� , _: O,t, <br /> Code. calculation indicates wmpliance ,y'��,, g; �,s� �`f <br /> _�� with the Florida Energy Code. �_:��'"• ;:�`�-''�� `� <br /> _ .� ,� � <br /> PREPARED BY: . __ Before construction is completed - � <br /> DA7E: ___ this building will be inspected for c� .,', i � d► <br /> compliance with Section 553.908 . ¢ <br /> I hereby certiy that this building, as design ,' in compliance �da Statutes. r,i, � <br /> with the Flarida Energy Code. Gtsc•il��' A <br /> OWNERJAGENT: �t11LDING OFF1CiAC:' _ - --- <br /> DATE: - DATE: -�� �I � �yn - <br /> - Comptfance requires certification by the ai� handler unit manufacturer that the al� handler enclosure <br /> qualffies as certified factory�saled in accordance with N1110A.3. <br /> 8t21281 i 2:29 PM EnergyC3aug� USA - FlaRes2008 Page 1 of 5 <br />