Laserfiche WebLink
� • r i � <br /> Zephyrhills Fire Rescue <br /> 6907 Dairy Road, Zephyrhills, FL 33542 <br /> Fire Chief Bus (813) 780-0041 <br /> Keith Williams Fax (813) 780-0044 <br /> 12 October 2011 <br /> This Officer has reviewed the submitted plans for a six (6) unit villa, new construction, at <br /> 37623 to 37643 Georgina Terrace, in the Eiland Park Townhome development. <br /> Following the review, a conditional approval to proceed is given. Payment for permit <br /> acknowledges acceptance and compliance of the conditions noted herein. The following <br /> items shall be considered: <br /> 1. Assurance of fire safe practices and in place in accordance to NFPA 1. <br /> 2. Unit 1398 does not include a smoke alarm in the master bedroom of that unit. <br /> One must be included per code. <br /> 3. All circuit breakers controlling the circuits servicing the smoke alarm and <br /> carbon monoxide detectors shall be equipped with a breaker lock to keep the <br /> breaker from being turned off (NFPA 101, 4.6- AHJ requirement). <br /> 4. Ensure that electrical meters are addressed with respective address <br /> designations. <br /> 5. Plans show UL listed fire wall separation constructed out of gypsum board. <br /> Conversations during previous inspections reflect that contractor is desirous to <br /> altering construction method. If this is so, then plans do not reflect true intent <br /> and revisions need to be submitted. <br /> 6. Fire wall separation shall extend through the soffit area to extreme outside of <br /> structure. <br /> 7. Not pertinent to this fire safety review but general notes on units do not reflect <br /> actual construction on previous units. Exhaust ventilation ducts terminate in <br /> soffit area on previous units. <br /> 8. Plan pages 55.1 and WP are missing from sets, noted, not affecting review. <br /> Inspections Required: <br /> 1. Firewall 1 St layer screw inspection, 2" layer screw inspection, final <br /> 2. Final building inspection <br /> Review and approval of the submitted plans does not relieve the contractor from the <br /> responsibility of correcting any deficiencies noted during inspections. <br /> Resp tfully s bmitted on 11 October 2011 by, <br /> � <br /> eith A. Williams, EFO, CFO, CMO, MIFireE <br /> Fire Chief <br /> Fire Safety Inspector <br />