FORM 1100A-08 <br /> Code Compliance Checklist <br /> Residential Who1e Building Performance Method A- Details <br /> ADDRESS: PERMIT #: <br /> , FL, <br /> INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> COMPONENTS SECTION RE QUIREMENTS FOR E ACH PRA CTICE CHECK <br /> Exterior Windows & Doors N1106.A6.1.1 '_ Maximum: .3 cfmisq.ft. window area; .5 cfmisq.ft. door area. <br /> Exterior 8� Adjace�t Walls N1106.AB.1.2 Caulk, gasket, weatherstrip or seal between: windows/doors 8 <br /> frames, surrounding wall; foundation 8 wall sole or sill plate; joints <br /> between exterior wall panels at comers; utility penetrations; <br /> betvveen wall panels & top/bottom plates; between walls and floor. i <br /> EXCEPTIDN: Frame wa11s where a continuous infiltration barrier is <br /> insta8ed that extends from, and is sealed to, the foundation to the <br /> _ _ __ top plate. _ <br /> Floors N1106.A6.1.2 Penetrations/openings > 1/8" sealed unless backed by truss or <br /> I joint members. <br /> EXCEPTION: Frame floors where a continuous infiitration barrier <br /> _ .__ is installed that is sealed to the perimeter, penetrations and seams. <br /> Ceilings N 1106.A6.1.2 Between walls 8� ceilings; peneuations of cei{ing plane to top floor; <br /> around shafts, chases, so�ts, chimneys, cabinets sealed to <br /> continuous air barrier, gaps in gyp board 8� top plate; attic access. <br /> EXCEPTION: Frame ceilings where a continuous infiftration barrier <br /> is installed that is sealed at the perimeter, at penetrations and <br /> seams. <br /> Recessed LigMlr►g Fixtures N1106.AB.1.2 Type IC rated with no penetrations, sealed; or Type IC or non-IC <br /> �ated, installed inside a sealed box with 1/2" clearance & 3" from <br /> insulation; or Type IC with < 2.0 cfm from conditioned space, <br /> tested. _ <br /> Multi-sto Houses N11,06.A8.1.2 Air barrier o� perimeter of floor cavity between floors. _ � <br /> Additional Infiltration reqts N1106.AB.1.3 Exhaust fans vented to outdoors, dampers; combustion space <br /> heaters comply with NFPA, have combustipn air. <br /> OTHER PRESCRIPTIVE MEASURES {must be met or exceeded by al{ residences.) <br /> COMPON�NTS SECTlON REQUIREMEN;S C HECK <br /> Water Heaters N1112.A8.3 Comply with e�iciency requirements in Table N1112.ASC.3 <br /> � Switch or clearly marked circuit breaker (electric) or cutoff (gas) <br /> _._ _ must be provided. External w built-in heat trap reauired. <br /> Swimming Pools & Spas N1112.AB.2.3 Spas & heated poots must have covers (except sotar heated). <br /> � Non-commerciat poofs must have a pump timer. Gas spa 8� pool <br /> heaters must have a minimum thermal efficiency of 7896. � <br /> Heat pump heaters shall have a minimum COP of 4.0 ' <br /> Shower he�ds N1112.AB.2.4 Water flow must be restricted to no more than 2.5 gallons per � <br /> . __ minute at 80 PS1G. <br /> Air Distribution Systems N11i0A6 All ducts, fittings, mechanical equipment and plenum chambers <br /> shall be mechanicaNy att�ched, sealed, insulated and installed in <br /> accordance with the criteria of Section N1110.AB. <br /> _._ Ducts in uncondit att ics: R-6 min. ins ulation. � <br /> HVAC ConVols N 1107.AB.2 Separate readily accessible manual or automatic thertnostat for <br /> ---._ each system. <br /> tnsulation N1104.AB.1 Ceilings-Min. R-19. Common walls-f�ame R-11 or CBS R-3 both <br /> N11Q2.B.1.1 sldes. Common ceiiing & floors R-11. <br /> 9J�J2011 8:55 AM EnargyGauge� USA - FIaRe82008 Page 5 of 6 <br />