Laserfiche WebLink
1 &2 Family Dwelling <br /> Plan Review Comments <br /> 1. F.f�.I:. Shal l h� a minimum �}f� 8" ah�� e tlle road ele��atioil and a en�ineered site ��lan. <br /> ?. Lc�ts shall he gi to compl�� ��►th R401.3 <�f the F.B.C' . <br /> 3. C'��m �action test reyuired if 2�" ur more of fill dirt is bmught in at any one }�(ace. <br /> 4. T�e in surve}� required before pour�ng ccmcrete. <br /> 5 Dnvew�ays require a R.O.VI' use �ern��t. <br /> G. All s�_tbacks shall he met. <br /> 7. All �roperty markers shall be uncc�vered and marked at time of first in��ecti<�n. <br /> R. All A.I3.A. reqwrements shall he met. <br /> y?�'c� ele�t� }�lumb�ng, mcchanicai. c�r fi�anling shall be co� ered ���ithc�ut an ii7specUc�i1 and <br /> apprc�� al first. <br /> 10. All C�arages shall com�ly with sect���n R309.2 <�fthe F.B.C. (Fire Separat��n). <br /> 1 1. Appliances shall not be installed in a l�cation ��here suh�ect tc� mechanical damage unless <br /> }�rotected hy approved barr�ers. M3U3.4 of the F.B.0 <br /> 12. VG'ater heaters shall cc,m�l� ���ith sect��n P6O7.3 �f the .F.B.C' <br /> 13. I� c�undation suppor[s for Ai(' units shall be raised at least 3" aba�°e finished grade. M] 30�.1 <br /> ] 4. Retur afr �n all bedroonls. F.B.('. I��f 162().4 <br /> 15. Smo�;e detectors are to be �nstalled in accordance ���ith R313.1 of the F.B.C'. <br /> l6. All glaz�ng reyuirements are to be �n accordance with R3U8.4 of�the F.B.C'. <br /> 17. All 1r►eans of egress are te� be �n acc�rdance ��-rth R311 of the F.B.C'. <br /> i 8. "C7reen g��sum board" shall not he used as a backer in sho��-ers oT� tubs. R702.�.2 F.I3.C'. <br /> l9 Cc�mlzination-t}��e AFC'I breakers are reyuired at all locations requinng a AFC'I type breaker. <br /> 20 Carb��n mc�nox�de alarms ��ill be reyuii in �iew construcUon that uses fassil-burning heating <br /> ��r apE�liances e�r an attached garage The} shall be installed i�� ace�rdanre ���tth the F.B.C. <br /> 21. All �lumhtng. mechan�ral. and �lectrical shall he separate from un�t t� uri�t. 7'h�s includes all <br /> unde� plumbing and electnc. <br /> ??. All �t)08 t�.E.C' C'odes �� �II be erlforced. <br /> 23. Tam� Res�stant Receptacles �n accordance ���th 406.13 of�the 2008 N.E.0 <br /> 22. In accc�rdanr.e ��-ith the I_and De� elopment Code, l��ts shall be sodded befc�re final at least ] 0 <br /> feet a� the structure. <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code (2007) <br /> R.O.W.-Right Of Way <br /> A.D.A.- Americans with Disabilities Act <br /> N.E.C.- National Electric Code <br />