Laserfiche WebLink
FORM 1100A-08 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Community Affairs Residential Performance Methvd A <br /> Project Name: 1399 TH 911 Buiider Name: LENNAR HOMES <br /> sa�c: 37G 18 G�oRGi�v� TF2rc- Permic oirce: �", }-u ,,� Zf�o,�(.J�e�/iGCs <br /> Cily, State, Zip: , FL , ���"���� s ��.` �� Permit Number. ✓ <br /> Owner: LENNA HdMES Jurisdiction: <br /> Design Locafion: FL, Tampa <br /> 1 New construction or existing New (From Plans) 9. Wall Types {1636.4 sqft.) Insulation Area <br /> 2. Single famity or muftiple family Multi-family a. Concrete Block - Int Insul, Common R=4.1 961.33 iN <br /> b. Concrete Blodc - Int Insul, Exterior R=10.1 488.44 ft' <br /> 3. Number of units, ff mulGple family 1 c. Freme - Wood, Adjacent R=11 0 188.&7 fl= <br /> 4, Number of Bedrooms 2 d. N/A R= it� <br /> 5. IS this a worst case? Yes 10. Ceiling Types (1400.0 sqft.} Insulation Area <br /> 6. Conditioned floor area (ft� 1400 a. Under Attic (Vented) R=30.0 1400.OQ ft° <br /> b. N/A t2= ft: <br /> T. Windows(128.0 sqH.) Description Area �. WA R= ft= <br /> a. U-Fador. Dbl, U=0.55 84.00 ft' <br /> SHGC: SHGC=0.29 11 Ducts <br /> b. U-Factor: Dbl, U=0.52 32.00 ft2 a. Sup: Attic Ret; Attic AH: Inierior Sup. R= 6, 310 ft' <br /> SHGC� SHGC=0.30 12. Cooling systems <br /> c. U-Factor: Dbl, U=0.51 32.00 ft' a. CeMral Unit Cap: 23.8 kBtulhr <br /> SHGC: SHGC=0.33 SEER� 15 <br /> d. U-Factor: N/A ft' 13. Heating systems <br /> SHGC: a. Efectric Heat Pump Cap: 22.0 kBtuThr <br /> e. U-Factor. N/A ftZ HSPF 9 <br /> SHCSC: <br /> 14. Hot water systems <br /> S. FborTypes (1400.0 sqft.) Insufatlon Area a. Electric Cap:40gallons <br /> a. Slab-On-Grade Edge Insulation R=0.0 1400.00 ft= EF: 0.92 <br /> b. WA R= �' b. Conservation features <br /> c. WA R= ft' None <br /> 15_ Credits Ps4at <br /> Total As-Built Modified Loads: 22.69 PASS <br /> G1ass/F1oor Area: 0.091 Total Baseline Loads: 30.96 <br /> { hereby certify that the plans and specifications covered by Review of the plans and ���THE STA <br /> this calculation are in compliance with the Florida Energy specifications covered by this �+ �; �O <br /> Code. cafculation indicates compliance �'� �, � ; = a� . � <br /> w i t h t he F lori da Energy C o de. ���:+„��.'N. -.`; :�r'. , O� <br /> PREPARED BY: �Q,.,,.,�t.� Before construction is completed �=-, � '" � <br /> DATE: .____ _____ this twilding will be inspected for � �, a► <br /> compliance with Section 553.908 .�° t <br /> 1 hereby certify that this building, as ciesign mpliance F�a�ida 5tatutes. � � <br /> with the Florida Energy Code. �GL� C � � <br /> OWNER/AGENT: _ BUILDING OFFICIAL: __ _. _._ <br /> DATE: __ . DATE: _�� ._..._- <br /> - Compliance requires oertification by the air handler u�it manufacturer that the air handler enclosure <br /> qual�es as certlfied factory-sealed in accordance with N1110A.3. <br /> 9rzrlot 1 a:32 QM EnergyGauge� USA - FIaRe82008 Page 1 016 <br />