Laserfiche WebLink
FORM 1100A-08 <br /> Code Compliance Checklist <br /> Residential Who1e Building PerFormance Method A- Details <br /> ADDRESS: PERMIT #: <br /> , FL, <br /> INFILTRATION REDUCTION COMPLlANCE CHECKLIST <br /> COMPONENTS : SECTION REQUIREMENTS FOR EACH PRACTICE _� CHECK <br /> Exterior Windows & Doors � N1106.AB.1 1 Maximum: .3 cfm/sq.ft. window ares; .5 cfmJsq.ft. door area. <br /> Exterior 8 Adjacent Walls N1106.A6.1.2 Caulk, gasket, weatherstnp or seal between: windowsldoors 8 <br /> framss, surrounding wall; foundation & wall sole or sill plate; joints <br /> � between e�cterior wall panels at comers; utility penet�ations; <br /> between wall panels 8 toplbottom plates; befi�veen walls and floor <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is <br /> installed that e�ctends from, and is sealed to, the foundation to the <br /> top plate. <br /> Floors N1106.AB.1.2 Penetratioris/openings > 1/8" sealed unless backed by truss or <br /> ' jant members. <br /> EXCEPTtON: Frame floors where a continuous infiltration barrier <br /> __ _ _ is installed that is sealed to the perimeter, penetrations and seams, .� <br /> Ceilings N1106.A6.1.2 Between walls 8 ceilings; penetrations of ceiling plane to top floor; <br /> around shafts, chases, soffits, chimneys, cabinets sealed to <br /> continuous air banier; gaps in gyp board & top plate; attic access. <br /> EXCEPTION: Frame ceiling5 where a continuous infiltration barrier <br /> is installed that is sealed at the perimeter, at penetrations and <br /> seams. <br /> --- - - - -- . x <br /> Recessed Lighting Fixxures N1106.A6.1.2 � Type IC rated with no penetrations, sealed; or Type 1C or n4n-IC <br /> rated, installed inside a sealed box vvith 1/2" dearance 8� 3" from <br /> insulation; or Type IC with < 2.0 cfm from conditioned space, <br /> t ested. <br /> Muki-story liouses N1106.AB.1.2 , Air barrier on perimeter of floor cavity bet�roeen floors. _ _ <br /> Additional Infiltration reqts N11�.AB.1.3 Exhaust fans vented to outdoors, dampers; combustion space � <br /> heaters oompty with NFPA, have combustion air. <br /> OTHER PRESCRIP'fIVE MEASURES (must be met or exceeded by all residenCes.) <br /> COMPONENTS SECTION REQUIREMENTS CHECK <br /> Water Heaters N1112.AB.3 � Comply with efficiency requirements in Table N1112ABC.3 <br /> ; Switch or clearly marked circuit breaker (eleu�ric) or cutoff {gas) <br /> must_be provided. Extemal ar bui[t-in heat Vep raquir,ed. . __ <br /> Stivimming Pools 8 Spas N1112.A8.2.3 Spas � heated pools must have covers (except solar heated). <br /> • Non-cammercial pools must have a pump timer. Gas spa S� pool <br /> heaters must have a minimum thermal efficiency of 78°�6. � <br /> _____ Heat um pool heaters shall have a minimum COP of 4 0. _ <br /> Shower heads N1112.AB.2.4 Water flow must be restricted to no more than 2.5 gallans per <br /> minute at 80 PSIG. <br /> Air Distribution Systems N1110.A6 Atl ducts, fittings, mechanical equipment and plenum chambevs <br /> shall be mechanically attached, sealed, insulated and installed in <br /> ; aeoordance with the criteria of Section N1110.A6. <br /> � Ducts in u nconditioned attics: R-6 min. insulation. <br /> � - - � -- - - - - <br /> HVAC Controls N1107.AB.2 � Separete readily accessible manual or automatic thermostat for � <br /> _. each system. __ _ _ _ <br /> Insulation N1104.A8.1 Ceilings-Min. R-i9. Common wefls-frame R-11 or CBS R-3 both <br /> N1102.8.1 1 � sides. Common ceiling & floors R-11 <br /> 912I2011 2:32 PM EnergyGauge�l USA - FlaRea2008 Paye 5 oi 5 <br />