Laserfiche WebLink
APPENDIX 13-D <br /> * TABLE 11B-t MINIMUM HEUUIHEMENTS (See Note 7) All Ciimate Zones <br /> BUILDING COMPONENT PERFORMANCE CRITERIA INSTALLED VALUES: <br /> U-Factor = 0.65 U-Factor = <br /> Windows (see Note 2): SHGC = 0.35 SHCaC =, 3 <br /> % of CFA <= 16% % of CFA = U <br /> Exterior door e Wood or insulated T e: <br /> Walls – Ext. and Adj. (see Note 3): <br /> Frame R-13 R-Value = � � <br /> Mass (see Note 3) <br /> Interior of wall: R-6 R-Value = <br /> EMerior of wall: R-4 R-Value = <br /> Electric resistance heat See Note 10 Not allowed <br /> Ceilin s see Notes 3 8 4 R=30 R-Value = <br /> Fioors: Slab-on-grade No requirement R-Value = <br /> Over unconditioned s aces see Note 3 R-13 <br /> Hot water systems (storage type) <br /> Electric (see Note 5): 40 gal: EF = 0.92 Gallons = <br /> 50 gal: EF = 0.90 EF = <br /> Gas fired (see Note 6): 40 gal: EF = 0.59 Gallons = '-- <br /> 50 al: EF = 0.58 EF = <br /> Air conditionin s stems see Note 7 SEER = 13.0 SEER = <br /> Heat pump systems (see Note 8) SEER = 13.0 SEER = �'3 <br /> HSPF = 7.7 HSPF = <br /> Gas fumaces AFUE = 78 % AFUE _ <br /> Oil fumaces AFUE = 78 % AFUE _ <br /> Pro rammable thertnostat see Note 10 Must be installed on all HVAC s stems. Installed? Yes N <br /> Ductwork: (see Noie 9) Location: �}�f'�G <br /> Unconditioned space R-6, TESTED Unconditioned space <br /> Conditioned space NA R-Value = �p <br /> Unvented attic assembly per R606.4 with insulation at the roof plane R-4.2 Test report: <br /> Conditioned space <br /> R-Vatue = <br /> No test re ort re uired <br /> Air Handler location: �/� <br /> Unconditioned attic or garage Requires test report Location: <br /> Conditioned space or Test report: <br /> Unvented attic assembl er R806.4 with insulation at the roof lane No duct test re uired <br /> (1) Each component present in the As-Built home must meet or exceed each of the applicable performance criteria in order to comply with this code using this method; oth- <br /> erwise Method A compliance must be used. <br /> (2) Windows and doors qualifying as glazed fenestration areas must comply with both the maximum U-Factor and the maximum SHGC (Solar Heat Gain Coefficient) criteria <br /> and have a maximum total wintlow area equal to or less than 16% of the conditioned floor area (CFA), otherwise Methotl A must be used Tor compliance. Exceptions:l Ad- <br /> ditions of 600 square feet (56 m or less may have maximum glass to CFA of 50 percent. 2. Renovations with new windows under>_ 2 foot overhang whose lower edge does <br /> not extend further than 8 feet from the overhang may have tinted glazing or double-pane clear glazing. Replacement skylights installed in renovations shall be doublepaned <br /> or single paned with a diffuser. <br /> (3) R•Values are for insulation material only as applied in accordance with manufacturers' installation instructions. For mass walis, the "interior oi wail" requirement (R-6) <br /> must be met except if at least 50% of the R-4 insulation value required for the "e�erior of wall" is installed e�Rerior of, or integral to, the wall. <br /> (4) Attic knee walls shall be insulated to same level as ceilings and shall have a positive means of maintaining insulation in place. Such means may include rigid insulation <br /> board or air barrier sheet materials adequately fastened to the attic sides of knee wall framing materials. <br /> (5) For other electric storage volumes, minimum EF = 0.97 -(0.00132 ` votume). <br /> (6) For other natural gas storage volumes, minimum EF = 0.67 -(0.0019 ' volume). <br /> (7) For all conventio�al units with capacities greater than 30,000 Btu/hr. for Small-Duct, High-Velocity units, Space Constrained units, and units with capacities less than <br /> 30,000 Btu/hr see Table 13-607.A6.3.2A of the Florida Building Code, Building, or Table N1107.AB.3.2A of the Florida Burlding Code, Residential. <br /> (Sj For all conventional units with capacities greater than 30,000 Btu/hr. For Small-Duct, High•Velocity units, Space Constrained units, and units with capacities less than <br /> 30,000 Btu/hr see Table 13-607.AB.3.2B of the Florida Burlding Code, Building, or Table N1107.AB.3.2B oi the Florida Building Code, Residential. <br /> (9) All ducts and air handlers shall be either located in conditioned space or tested by a Class 1 BERS rater to be "substantially" leak free. "Substantially leak free" shall mean <br /> distribution system air leakage to outdoors no greater than 3 cfm per 100 square feet oi conditioned floor area at a pressure differential of 25 Pascal (0.10 in. �c.) across the <br /> entire air distri6ution system, including the manufacturer's air handler enclosure. Exception: New or replacement ducts installed onto an existing air distribution system as <br /> part of an addition or renovation. Such ducts shall either be insulated to R-6 or be installed in conditioned space. <br /> 10) The prohibition on electric resistance heat and the requirement for programmable thermostats do not apply to additions, renovations, and new heating systems installed <br /> in existing buildings. <br /> TABLE 11 B-2 MINIMUM RE�UIREMENTS FOR ALL PACKAGES <br /> COMPONENTS SECTION REQUIREMENTS CHECK <br /> Exterior Joints & Cracks N1106.AB.1.2 To be caulked, asketed weather-stri ed or othenvise sealed. <br /> Exterior Windows & Doors N1106.A8.1.1 Max .3 cfm/s .ft. window area; .5 cfm/s .fl. door area. <br /> Sole 8 To Plates N17 06.A6.12.1 Sole letes and enetrations throu h to lates of euterior walls must be sealed. <br /> Recessetl Li htin N1106.AB.12.4 T e IC reted with no enetrations [wo altematives allowed . <br /> Multisto Houses N1106.A8.12.5 Air barrier on erimeter ot floor ravi between floors. <br /> Exhaust Fans N1106.A8.1.3 �haust fans vented to unconditionetl space shall have tlampers, except for combustion devices with integral <br /> exhaust ductwork. <br /> Water Heaters N1112.A8.3 Comply with efficiency requirements in Table Nt 112.AB.3. Switch or clearly marked circuit breaker electric or cutoff <br /> as must be rovided. External or built-in heat tra re uired for vertical i e risers. <br /> Spas & heated pools must have covers (except solar heated). Noncommercial pools must have a pump timer. Gas <br /> Swimming Pools & Spas N7112.AB.2.3.4 spa & pool heaters must have minimum thermal effciency of 78%. Heat pump pool heaters shall have a minimum <br /> COP of 4.0. <br /> Hot Water Pi es N1112.AB.5 Insuletion is re uired for hot water circulatin s stems includin heat recove units . <br /> Shower Heads N1112.AB.2.4 Water flow must be restricted to no more than 2.5 allons er minute at 80 si . <br /> HVAC Duct Construction, All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated `/ <br /> Insulation 8 Installation N1110.A8 and installed in accortlance with the criteria of Section Nt 710.A8. Ducts in attics must be insulated to a minimum of y <br /> R-6. <br /> HVAC Controls N1107.AB2 Se arate readil accessible manual or automatic thermostat for each s stem. <br /> 13-D.24 2007 FLORIDA BUILDING CODE—BUILDING <br />