Laserfiche WebLink
Zephyrhil�s Fire Rescue <br /> 6907 Dairy Road, "Lephyrhills, FL 335�2 <br /> 1� ire Marshal 13u5 (813 ) 780-0041 <br /> Kerry l3arnett I�ax (8l ;} 780-UU�� <br /> E-mail: kbarnelt�Ltire.lephyrhills.fl.us <br /> Plan Review #: 11-128 <br /> Project: Revision — Build-outlRenovation <br /> Number of Pages: 13 <br /> October 28, 2011 <br /> I have received and reviewed the plans submitted for the interior build-out/renovation located at <br /> Zephyr Commons (7856/7860 Gall Blvd) and will allow the project to move forward. By paying <br /> for permit, contractor acknowledges in complying with the comments below. Should anyone have <br /> any questions, please do not hesitate to contact the Fire Marshal's office. <br /> 1. Safe practices in accordance to NFPA 1 shall be used during this project. <br /> 2. The fire alarm and fire sprinkler contractor will have to submit separate plans along with <br /> license and insurance to obtain a permit to perform the work on those systems. Plans shall <br /> include all details and cut sheets of products/devices used. <br /> 3. Fire wall shall be fire caulked at roof deck and around all penetrations to maintain fire <br /> rating. Once complete, firewall shall be labeled every 10 — 12 feet ` DO <br /> NOT PENETRATE" <br /> 4. Two fire extinguishers will be required in space D4 due to travel distance. <br /> 5. Ensure address is located both on front and rear doors. <br /> 6. Ensure electric meters are addressed. <br /> 7. Install emergency lights in restrooms. <br /> 8. Install lightweight truss sign in accordance to FL Statute. <br /> 9. A key will be required for the knox box located at the front of the building once project is <br /> complete and locks have been changed. <br /> Inspections Required: <br /> 1. Fire wall Screw lnspect <br /> 2. Fire wall Final <br /> 3. Building Final <br /> KERR NETT, FIRE MARSHAL <br /> ***Please be advised this review of plans submitted is a cursory review to assist the contractor in <br /> compliance with applicable fire safety codes. This review is not intended to be a final approval of the <br /> submitted plans. It is the contractor's sole responsibility to ensure that the plans are in complete compliance <br /> with all applicable NFPA codes and local ordinances. In the event that further examination or site <br /> inspection reveals areas of non-compliance, it shall be the contractor's sole responsibility, at their sole <br /> expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure <br /> to be in compliance with all applicable NFPA codes and local ordinances. <br />