My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-12638
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-12638
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/20/2012 2:25:15 PM
Creation date
6/20/2012 2:25:12 PM
Metadata
Fields
Template:
Building Department
Company Name
ADVENTIST HEALTH SYSTEM SUNBELT
Building Department - Doc Type
Permit
Permit #
11-12638
Building Department - Name
ADVENTIST HEALTH SYSTEM SUNBELT
Address
7050 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Zephyrhills Fire Rescue <br /> 6907 Uairy Road, "L.ephyrhills, T'L 335�2 <br /> {�'ire Marshal Bus (813) 780-0041 <br /> Ker�•v 13arnett Fax (8l3) 780-UO��t <br /> y �-mail: kbarnett�u.tire.zephyrhills.f7.us <br /> Plan Review #: 11-137 <br /> Project: Building Rehab — Angio Rm <br /> Number of Pages: 66 <br /> December 19, 2011 <br /> I have received and reviewed the plans for the building rehabilitation located at 7050 Gall <br /> blvd for an angio room located at Florida Hospital. At this time, this project will be allowed <br /> to move forward. Paying for permit, contractor acknowledges complying with the items listed <br /> below. Should anyone have any questions, please do not hesitate to contact the Fire <br /> Marshal's office. <br /> 1. Use safe practices during construction in accordance to NFPA 1. <br /> 2. Several plan pages were miss labeled. Roof Plan page is A2.5 not A2.4, Partial Roof <br /> Plan - Plumbing page is P2.2 not P23, and Siemens added a Medical Equipment page <br /> not indicated on the main cover page. <br /> 3. If any of the fire protection systems are shut down for 4 hours or more, this authority <br /> shall be notified. Fire watch shall be set up and appropriate documentation shall be <br /> filled out by those conducting the fire watch. Once fire watch is lifted, notify this <br /> authority and the paperwork shall be forwarded to this authority. <br /> 4. Ensure AHU has a duct detector (over 2000 cfm's) <br /> 5. Separate plans will be required to be submitted by the contractor making changes to <br /> the fire alarm and fire sprinkler system. Plans shall be submitted along with cut <br /> sheets, details, calculations, etc... <br /> 6. Several methods were noted in the plans for protecting the different penetrations in <br /> the rated walls/floors/ceilings. The contractor shall provide which method is being <br /> used to this authority at the time the penetration inspection is being conducted. <br /> 7. Where any valves or dampers are located above ceiling, label and/or mark ceiling tile <br /> in that location as such. <br /> 8. Building Official is responsible for med gas inspection. <br />
The URL can be used to link to this page
Your browser does not support the video tag.