Project: RDT <br /> Title: RDT Office Addition 576 e <br /> Type: Office <br /> (WEA File: FL_TAMPA_INTERNATIONAL_AP.tm3) <br /> Other Required Compliance <br /> Category Section Requirement(write N/A in box if not applicable) Check <br /> Report 13-101 Input Report Print-Out from EnergyGauge FlaCom attached <br /> Operations Manual 13-102.1, Operations manual provided to owner <br /> 13-410, 13-413 / <br /> Windows&Doors 13-406.AB.1.1 Glazed swinging entrance&revolving doors:m�. ].0 cfm/ft2;all u <br /> other products:0.4 cfin/ft2 � <br /> Joints/Cracks 13-406.AB.1.2 To be caulked,gasketed,weather-stripped or otherwise sealed <br /> Dropped Ceiling Ca�ity 13-406.AB3 Vented:seal&insulated ceiling.Unvented seal&insulate roof& � <br /> side walls / <br /> System L.i-407 HVAC Load sizing has been performed � <br /> Reheat 13-407.B Electric resistance reheat prohibited � <br /> HVAC Efflciency 13-407, 13-408 Minimum efficiences:Cooling Tables 13-407.AB.3.2.1A-D; d <br /> Heating Tables 13-407.AB.3.2.1B, 13-407.AB.3.2.1D, <br /> 13-408.AB.3.2.1E, 13-408.AB3.2F / <br /> HVAC Controls 13-407.AB.2 Zone controls prevent reheat(exceptions);simultaneous heating u <br /> and cooling in each zone;combined HAC deadband of at least 5°F <br /> (exceptions) / <br /> Ventilation Controls 13-409.AB.3 Motorized dampers reqd,except gravity dampers OK in: 1)exhaust J <br /> systems and 2)systems with design outside air intake or exhaust <br /> capacity<300 cfm / <br /> ADS 13-410 Duct sizing and Design have been performed J <br /> HVAC Ducts 13-410.AB Air ducts,fittings,mechanical equipment&plenum chambers shall � <br /> be mechanically attached,sealed,insulated&installed per Sec. <br /> 13-410 Air Distribution Systems � <br /> Balancing 13-410.AB.4 HVAC distribution system(s)tested&balanced.Report in <br /> construction documents � <br /> Piping Insulation 13-411.AB In accordance with Table 13-411.AB.2 <br /> Water Heaters 13-412.AB Performance requirements in accordance with Table 13-412.AB.3. � <br /> Heat trap required <br /> Swimming Pools 13-412.AB.2.6 Cover on heated swimming pools:Time switch(exceptions); �. <br /> Readily accessible on/off switch <br /> Hot Water Pipe 13-411.AB.3 Table 13-411.AB.2 for circulating systems,first 8 feet of outlet � <br /> Insulation pipe from storage tank and between inlet pipe and heat trap <br /> Water Fixtures 13-412.AB.2.5 Shower hot water flow restricted to 2.5 gpm at 80 psi.Public � <br /> lavatory fixture how water flow 0.5 gpm max;if self-closing valve <br /> 0.25 gallon recirculating,0.5 gallon non recirculating / <br /> Motors 13-414 Motor efficiency criteria have been met �u <br /> Lighting Controls 13-415.AB Automatic control required for interior lighting in buildings>5,000 <br /> s.f.;Space control;Exterior photo sensor;Tandom wiring with 1 or <br /> 3 linear fluuorescent lamps>30W <br /> EnergyGauge Summit�Fla/Com-2008. Effective:March 1,2009 <br /> 8/26/2009 Page 8 of 8 <br />