Laserfiche WebLink
�OS��I R. EVAwS, P.E. F�n: F16339-R2 <br /> 1333 Sunset Drive,Winter Park,FL 32789 Report#: 190 <br /> PH:407-644-8161 FX:407-647-3572 Date: 6/25/2008 <br /> Product Evaluation Report <br /> P y �I tion A�Tested): 11A�nufe�t�arer Test Agen <br /> � Single Hung Window Jacobson Window Company National Certified Testing Lab. <br /> `�-` Series 1000 1707 W.North"A"Street 8350 Parkline Blvd.,Ste 12 <br /> � 53-1/8"X 76 Tampa,FL 33606 Orlando,FL 32809 <br /> 51"X 38-1/4" PH 813.259.1482 PH 407.240.1356 <br /> 3/16"Annealed Glass <br /> �.� " =2 X 4 TDL-3/16"Annealed Glass(11.25"X 16J5") <br /> 48-7/8"X 35„ <br /> Aluminum 0663-T5 <br /> k I�t1an� ufreman�st: <br /> See reference drawing Notes on Sheet i for installatlon instructions and Iimitations. Refer to drawings for table of span vs,loads. <br /> This product DOES NOT comply with the High Velocity Hurricane Zone(HVHZ)testing requirements. <br /> 1CB003 <br /> t�8 wood screws with 1.5"embedment into Wood Substrate <br /> .�r.P`' '.;°�aa;_._' .�;' 3/16" Elco Tapcon with 1.25"embedment into Concrete/Masonry Substrate <br /> e�. Head&Sill: (Flange)4"from corner,Max 9"O.C.;(Fin)4"from corner,Max 22.5"O.C. <br /> ,�;�: .!..� ,� � �� <br /> . .y:. .-,a,;.�»,.Jamb:(Fiange)3"from corner,Max 10 O.C.;(Fin)3'from corner,Max 17.5 O.C. <br /> a�r+ <br /> ,o,.�, �Optional Slip-On Fin is used to fasten the frame around the full perimeter of the window. See Installation Instructions <br /> `��°� - �_> �x;a JWC011 for more details. <br /> Prodqct Teat�n Summa :(in aaordan wit�ANSI AAMA/NWWDA 101 1.&•2-97 <br /> UnHorm Static Air InBkratbn <br /> 5����� Sixe Tested ���6uratbn Preuure ASTM E 283/ Forced Entry Desfg�Pressure <br /> Number tested ASTM E 330 Water Penetwtfon ASTM F 842 (PSF) Glazing <br /> (PSF� ASTM E 331 <br /> Test Re :NCTL-21p 3178•$- :Gerard FBrreYS 14 A PEIi il 5-Date:li 22/05 <br /> 1 53-1/8"X 76" O/X �5 Passed Passed 50 A <br /> Test Re rt:NCTL-2i0•;i s i iiArA F �• 5-Date:ii t OS <br /> 1 53-1/8"X 76" ��x �67.5 Passed Passed 45 B <br /> Comparative Analysis Used: �X� YES � � NO (As per guidelines for HVHZ for Dade County.) <br /> I�1.1.Wo�I1 �y;''a;_� �V1v1iLY WIT�"�I�I,L <br /> PREVAIL�?tiC���t t+:�ES,FLORIDA Fs[1ILDI��G <br /> CODE,;��"1?i�f�lAL ELECTRIC COL�E A��' <br /> C1TY���ICPHYRHILLS ORDINANCES <br /> Statement of Campliance: ^�� � <br /> Under the limitations of the attached drawings,and to the best of my knowledge and ability,the above window/d:.or prod+.K�confarms to the <br /> requirements of the 2007 Florida Building Code. <br /> �- f 7- .��' <br /> �-.- <br /> 1�p R€va ns,��/ <br /> Florida N�.d392 <br /> 0:\Projects�lacobson Windows\P-0806-04(Master List�\04.102(FBC-Senes 1000 SH�\DOCS\Report 190 Jacobson 1000 FL6339-R1 Page 1 of 1 <br />