My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
09-9588
Zephyrhills
>
Building Department
>
Permits
>
2009
>
09-9588
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/16/2013 10:28:10 AM
Creation date
1/16/2013 10:28:08 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
09-9588
Building Department - Name
PONCHOT,JAMES & MARY
Address
38532 13TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Product Manufacturer: <br /> , Gulf Coast Supply&Mfg, Inc. <br /> 4020 S.W. 449th Street <br /> Horseshoe Beach, FL 32648 <br /> 352-498-7852 <br /> Product Description: <br /> Tuff Rib Roof Panel, 26 Ga. 0.0185", 36°Coverage, 3/4°Tall Rib, non-structural metal roof panel over 1x4 <br /> wood purlins attached to min. 15/32° Plywood. <br /> Panel Rollformer: MRS Metal Rollforming Systems <br /> 13906 N. Newport HWY <br /> Mead, Washington 99021 <br /> Compliance Statement: <br /> The product as described in this report has demonstrated compliance with the Florida Building Code <br /> 2007, Sections 1504.3.2. <br /> Documentation Supporting the Compliance Statement: <br /> The product has been tested in accordance with: <br /> • UL 580-94/1897-98 by Force Engineering &Testing <br /> • Test Report#117-0062T-07D, E dated 2-19-07 <br /> A) Test#1 Main Tested 9-13-06 <br /> B) Test#2 Edge Tested 9-22-06 <br /> Limitations and Conditions of use for NON-HVHZ: <br /> Maximum Roof Component Uplift Pressures:-109.25 psf @ 9"-9"-9°-9"Fastener Pattern at 24"O.0 <br /> -164.25 psf @ 9"-9"-9°-9"Fastener Pattem at 12"O.C. <br /> Panel Material StandaMs: 26 Ga., 0.0185"Thick material Grade 80. Panel Material shall <br /> comply with FBC 2007, Section 1507.4.3 <br /> Panel Fasteners: #9-15 x 1-1/2"HWH Woodgrip w/Sealer Washer. Fasteners <br /> must be Corrosion resistance per FBC 2007, Section 1507.4 4 <br /> Minimum Roof Slope: 2:12. Minimum Slope shall comply with FBC 2007, Section <br /> 1507.4.2 and Manufacturers recommendations. <br /> Substrate Description: 1x4 Wood Purlins attached to Min. 15/32"Plywood Deck <br /> designed by others <br /> Vapor Barrier: 30#Asphalt Saturated organic felt paper in compliance with <br /> ASTM D226, Type I or Type I I. <br /> Roof Panel Fire Rating: Panel has a Class B fire exposure rating in accordance with <br /> FBC Section 1505.3 without added an additional fire barrier. <br /> ,,'��{1{111/��,,' <br /> ,,�� �N C E. � �4 Ii <br /> i� <br /> �, ���. � C � �sF `n`�i <br /> �,��; •;A,� ,--- <br /> � (_.. <br /> _' i + �' � Pb.41➢� `_ 1 �`'�'!-��_� <br /> � � �,'T' 1/'�t�� L.. 4� t�L <br /> _,���� ,� � <br /> � 'a' STA7E OF ,•qC�f <br /> %��'`�• FLORI�4' •��`'.` <br /> a�ro� ���,S;S;.. - . ���.�'�. <br /> ,�''aiiir�:.��. <br /> 2 of 3 November 9, 2 0 0 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.