Laserfiche WebLink
Project: Florida Medical <br /> Title:Florida Medical Surgery Center <br /> Type:Hospital <br /> (WEA File: FL_TAMPA_INTERNATIONAL_AP.tm3) <br /> Other Required Compliance <br /> Category Section Requirement(write N/A in box if not applicable) Check <br /> Report 13-101 Input Report Print-0ut from EnergyGauge FlaCom attached <br /> Operahons Manual 13-102.1, Operations manual provided to owner � <br /> 13-410, 13-413 <br /> Windows&Doors 13-406.AB.1.1 Glazed swinging entrance&revolving doors:maac. LO cfm/ftz;all � <br /> other products:0.4 cfm/ft2 � <br /> Joints/Cracks 13-406.AB.1.2 To be caulked,gasketed,weather-stripped or otherwise sealed <br /> Dropped Ceiling Cavity 13�06.AB.3 Vented:seal&insulated ceiling. Unvented seal&insulate roof& � <br /> side walls � <br /> System 13-407 HVAC Load sizing has been performed <br /> Reheat 13-407.B Electric resistance reheat prohibited � <br /> HVAC Ef�iciency 13-407, 13-408 Minimum efficiences:Cooling Tables 13�07.AB3 2.1A-D; d <br /> Heating Tables 13-407.AB.3.2.1 B, 13-407.AB.3.2.1 D, <br /> 13-408.AB3.2.1 E, 13-408.AB.3.2F <br /> HVAC Controls 13-407.AB.2 Zone controls prevent reheat(exceptions);simultaneous heating <br /> and coolmg in each zone;combined HAC deadband of at least 5°F <br /> (exceptions) / <br /> Ventilation Controls 13-409.AB.3 Motorized dampers reqd,except gravity dampers OK in: 1)exhaust u <br /> systems and 2)systems with design outside air intake or exhaust <br /> capacity<300 cfin � <br /> ADS 13-410 Duct sizing and Design have been performed <br /> HVAC Ducts 13�10.AB A�r ducts,fittings,mechamcal equipment&plenum chambers shall � <br /> be mechanically attached,sealed,insulated&installed per Sec. <br /> 13-410 Air Distribution Systems <br /> Balancing 13�10.AB.4 HVAC distribution system(s)tested&balanced.Report in � <br /> construction documents <br /> Piping Insulation 13�11.AB In accordance with Table 13-411.AB.2 � <br /> Water Heaters 13-412.AB Performance requirements in accordance with Table 13-412.AB3. � <br /> Heat trap required <br /> Swimming Pools 13-412.AB.2.6 Cover on heated swimming pools:Time switch(exceptions); � <br /> Readily accessible on/off switch � <br /> Hot Water Pipe 13�1 I.AB.3 Table 13-411.AB.2 for circulating systems,first 8 feet of outlet <br /> Insulation pipe from storage tank and between inlet pipe and heat trap � <br /> Water Fixtures 13-412.AB.2.5 Shower hot water flow resficted to 2.5 gpm at 80 psi.Public <br /> lavatory fixture how water flow 0.5 gpm max;if self'-closing valve <br /> 0.25 gallon recirculating,0.5 gallon non recirculating � <br /> Motors 131114 Motor efficiency criteria have been met <br /> Lighting Controls 13-415.AB Automatic control required for inter�or lighting in buildings>5,000 <br /> s.f.;Space control;Exterior photo sensor;Tandom wiring with 1 or <br /> 3 linear fluuorescent lamps>30W <br /> EnergyGauge Summit�FlalCom-2008. Effective:March 1,2009 <br /> 3/18/2011 Page 11 of 11 <br />