My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-11964
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-11964
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/16/2013 11:27:34 AM
Creation date
1/16/2013 11:27:28 AM
Metadata
Fields
Template:
Building Department
Company Name
FLORIDA MEDICAL CLINIC
Building Department - Doc Type
Permit
Permit #
11-11964
Building Department - Name
FLORIDA MEDICAL CLINIC
Address
38135 MARKET SQUARE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, r-�-�-�..�---"�2�" <br /> Zephyrhills Fire Rescue <br /> 6907 Uairy Roaci, Gephyrhills, I�L 335�42 <br /> l�'ice Marshal 13u5 (813) 780-0041 <br /> Kerry l3arnetl F�aa (813} 78Q-U044 <br /> E-mail: kbar�lett(a)f7re.zephyrhills.fl.us <br /> Plan Review#: l 1-031 <br /> Project:New Construction(addition) <br /> Number of Pages: 154 <br /> Aprill 1, 2011 <br /> I have received and reviewed the plans for the ex ansion located uare Drive <br /> and will require further information before t project will be allowed to move forwar Please <br /> submit necessary documentation addressing the items below. Should anyone have any questions, <br /> please do not hesitate to contact the Fire Marshal's office. <br /> 1. Separate plans, along with specs and cut sheets, will be required to be submitted to <br /> this authority to obtain permit for installation/modification of fire alarm system, fire <br /> sprinkler system, and generator. <br /> 2. Ensure there are new calculations provided with the fire alarm and fire sprinkler <br /> system plans. <br /> 3. Fire sprinkler system allows a single riser for up to 52,000 square feet. An additional <br /> riser will be required for going over that square footage. Also, change the existing <br /> FDC to the 30 degree turn down 5" Storz connection. Repaint backflow preventor <br /> (red). <br /> 4. Details, cut sheets, and specs shall be provided to this authority for oxygen tank and <br /> other related gases. <br /> 5. Install proper fire lane markings on west and north sides of the building. See NFPA 1 <br /> Handbook for examples. <br /> 6. Knox Box will be required to be installed at both main entrances. A master key will <br /> be placed in the box. An application can be obtained from this authority. <br /> 7. Evaluate for lightweight truss sign in accordance to Florida Statute. Sign shall be <br /> installed to the left of main door at a height of 4-6 feet. Since building is longer than <br /> l00 feet, signs shall be installed every 100. <br /> 8. LS Page l, mentions standpipes, ensure plans are submitted for this item. <br /> 9. On Page T2, under the square footage breakdown-conditional area, the square footage <br /> is backwards for existing and proposed. <br /> 10. Rm 115 (electric room) shall have a 1 hour rating. Door shail also be rated. <br /> 1 l. Rm 173 & 174 shall be rated. <br /> 12. Ensure all exit doors have panic hardware. <br /> 13. Label all doors of electric, mechanical,janitor, etc rooms as such. <br /> 14. Ensure duct detectors are tied to the building fire alarm system. <br /> 15. Install emergency lights or a circuit on the life safety in all public restrooms and <br /> patient changing rooms. <br />
The URL can be used to link to this page
Your browser does not support the video tag.