My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
12-12724
Zephyrhills
>
Building Department
>
Permits
>
2012
>
12-12724
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/25/2013 1:02:09 PM
Creation date
1/25/2013 1:02:06 PM
Metadata
Fields
Template:
Building Department
Company Name
GOLDEN CORRAL
Building Department - Doc Type
Permit
Permit #
12-12724
Building Department - Name
GOLDEN CORRAL
Address
6851 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> SECTION IV – SYSTEM DESIGN <br /> UL EX3470 ULC EX3470 Page 4-1 <br /> 7-1-09 REV.8 <br /> SYSTEM DESIGN GENERAL INFORMATION <br /> The ANSUL R-102 Restaurant Fire Suppression System may be 1.Noules must be located 2-8 in.(5-20 cm)into the center of the <br /> used on a number of different types of restaurant cooking appli- duct opening,discharging up.See Figure 1. <br /> ances and hood and duct configurations.The design information <br /> listed in this section deals with the limitations and parameters of <br /> this pre-engineered system.Those individuals responsible for the <br /> design of the R-102 system must be trained and hold a current <br /> ANSUL certificate in an R-102 trainin r ram. •�� <br /> 9PP9 <br /> The R-102 and the PIRANHA systems use compatible agents and <br /> components, therefore, they may be used together for cooking <br /> appliance, hood, and duct protection. The primary ANSUL <br /> AUTOMAN Release can be either an R-102 or a PIRANHA <br /> ANSUL AUTOMAN Release and can actuate up to two additional " <br /> R-102 or PIRANHA Regulated Actuators. In systems utilizing a <br /> 101 remote release,any combination of the maximum number of <br /> regulated actuators can be used. z-a iN. <br /> • Both systems must actuate simultaneously. �5-zo�m� � <br /> • Each system must be designed and installed per its appropri- <br /> ate manual. FIGURE 1 <br /> 000,n <br /> • Adjacent appliances requiring protection must be protected 2.In instaliations where a UL listed damper assembly is <br /> with the same type of system, either R-102 or PIRANHA, employed, the duct noule can be installed beyond the 8 in. <br /> unless the center-to-center spacing between the adjacent (20 cm)maximum,to a point just beyond the damper assem- <br /> ' R-102 and PIRANHA nozzles is no less than 36 in.(91.4 cm). bly that will not interfere with the damper.Exceeding the maxi- <br /> • When appliances are protected with R-102 nozzles, the hood mum of 8 in.(20 cm)in thls way will not void the UL listing of <br /> and connecting duct above those appliances cannot be pro- the system. <br /> tected with PIRANHA nozzles. 3.Previously listed 3 flow number and 5 flow number duct pro- <br /> • Mixing systems in a common plenum is not allowed. tection detailed in earlier published manual, Part No.418087- <br /> One of the key elements for restaurant fire protection is a correct 06,can also still by utilized. <br /> system design.This section is divided into ten sub-sections:Noz- DUCT SIZES UP TO 50 IN.(127 cm) <br /> zle Placement Requirements,Tank Quantity Requirements,Actu- PERIMETER/16 IN.(41 cm) DIAMETER <br /> ation and Expellant Gas Line Requirements, Distributfon Piping <br /> Requirements, Detection System Requirements,Manuai Pull Sta- • One 1 W nozzle(Part No.419336)�one flow number <br /> tion Requirements, Mechanicai Gas Valve Requirements, Electri- <br /> cal Gas Valve Requirements, Electrical Switch Requirements,and ' 50 in.(127 cm)perimeter maximum <br /> Pressure Switch Requirements. Each of these sections must be • 16 in.(41 cm)diameter maximum <br /> completed before attempting any installation. System design <br /> sketches should be made of all aspects of design for reference DUCT SIZES UP TO 100 IN.(254 cm) <br /> during installation. PERIMETER/32 IN.(81.3 cm) DIAMETER <br /> NOZZLE PLACEMENT REQUIREMENTS • One 2W Nozzle(Part No.419337)�two flow numbers <br /> This section gives guidelines for nozzle type, positioning, and • 100 in.(254 cm)perimeter maximum <br /> quantity for duct,plenum,and individuai appliance protection.This <br /> secUon must be completed before determining tank quantity and ' 32 in.(81.3 cm)diameter maximum <br /> piping requirements. The chart beiow shows the maximum protection available from <br /> Duct Protectlon–Single Nozzle each duct nozzle. <br /> All duct protection is UL listed without limitation of maximum duct Description Nort S s eml�n �•5�allon <br /> length (unlimited length).This includes all varieties of ductworks — y _ System <br /> both horizontal and vertical incfuding ducts that run at angles to 2W Nozzle 419337 Maximum Maximum <br /> the horizontal and ducts with directional bends. 100 in.(254 cm) 100 in.(254 cm) <br /> The R-102 system uses different duct nozzles depending on the Perimeter Perimeter <br /> size of duct being protected. 1 W Nozzle 419336 Maximum Maximum <br /> 50 in.(117 cm) 50 in.(127 cm) <br /> Perimeter Perimeter <br /> �� <br />
The URL can be used to link to this page
Your browser does not support the video tag.