My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
12-12733
Zephyrhills
>
Building Department
>
Permits
>
2012
>
12-12733
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/25/2013 1:11:46 PM
Creation date
1/25/2013 1:11:45 PM
Metadata
Fields
Template:
Building Department
Company Name
MERCHANTS STATION LLC
Building Department - Doc Type
Permit
Permit #
12-12733
Building Department - Name
MERCHANTS STATION LLC
Address
7339 7343 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Zephyrhills Fire Rescue <br /> 6907 Dairy Road, Zephyrhills, FL 33542 <br /> Fire Chief Bus (813) 780-0041 <br /> Keith Williams Fax (813) 780-0044 <br /> 25 January 2012 <br /> Plan Number 12-004 <br /> Project: Anytime Fitness, 7341 Gall Blvd. <br /> Number of Pages: 13 <br /> Date received: by this Office O 1-12-2012 <br /> This Officer has reviewed the revised plans for the Renovation and Construction of <br /> Anytime Fitness located at 7341 Gall Blvd, Zephyrhills. Following the review, a <br /> conditional approval to proceed is given. Payment for permit acknowledges acceptance <br /> and compliance of the conditions noted herein. The following items shall be considered: <br /> 1. Assurance of fire safe practices and in place in accordance to NFPA 1. <br /> 2. Page G2 states that no work is scheduled for the existing 1-hour tirewall <br /> separating this unit form adjacent existing units. Existing firewall will need <br /> inspection to assure that no un-protected penetrations exist or that any repairs <br /> or required labeling is satisfactorily completed. <br /> 3. Emergency light needs to be added in storage room and tanning b�oth room. <br /> 4. Since the exit door in storeroom is identified as not being an exit, no exit <br /> signage shall lead to the storage room, and entrance door to the storage room <br /> door shall be marked as "Not an Exit". <br /> 5. Plans show emergency lights and exit lights close together, combination <br /> emergency light/exit light units may be utilized. <br /> 6. Notes (see Page A-3) for interior door opening effort does not state the effort <br /> it takes to open the door. They shall not exceed that force required for <br /> operating the exit doors (8.5 pounds, per NFPA). <br /> 7. Existing front exit door in current southern most original unit shall not have <br /> an exit sign if the door is to remain locked as stated on the plans, if it is to be <br /> locked it shall be indentified with"Not an Exit" signage. Should that door be <br /> utilized it must have panic hardware and appropriate access and li;hting. <br /> 8. Rear doors shall have numerical street address on them. <br /> 9. Circuit breakers in panel box shall be labeled identifying circuits. <br /> 10. There is a current fire sprinkler system, changes to the system will require <br /> plan submittal, review and inspection(s). <br /> 11. There shall be a supervised fire alarm system due to the presence of a fire <br /> sprinkler system. A final fire alarm acceptance test will be required. <br /> 12. Knox box key box must contain key to access this unit. <br /> Inspections Required: <br /> 1. Fire Wall inspection. <br /> 2. FinalInspection. <br />
The URL can be used to link to this page
Your browser does not support the video tag.