Laserfiche WebLink
SpectrAlert Advance Specifications <br /> General <br /> SpectrAlert Advance homs,strobes and horn/strobes shall mount to a standard 4 x 4 x 1�k-inch back box,4-inch octagon back box or double-gang back <br /> box.Two-wire products shall also mount to a single-gang 2 x 4 x 1'/e-inch back box.A universal mounting plate shall be used for mounting ceiling and wall <br /> produc[s.The notification appliance dreuit wiring shaii terminate at the universal mounting plate.Also,SpectrAlett Advance products,when used with the <br /> Sync•Circuit"i�iodule accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When <br /> used with the Syno-Grcuit Module,l2-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts;24-volt rated notification <br /> appliance circuit outputs shall operate between 17 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit <br /> from a regulated DC,or full-wave rectified,unfiltered power supply.5irobes and hom/strobes shall have field-selectable candela settings induding 15,15/75,30, <br /> 75,95,710,115,135,150,177,185. <br /> Strobe <br /> The strobe shall be a System Sensor SpectrAlert Advance��todel listed to UL 1971 and shall be approved for fire protective service.The strobe shall be <br /> wired as a primary-signaling notification appliance and complywith the Americans with Disabilities Ac[requirements Forvisible signaling appliances,flashinq at <br /> 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and assoaated lens/reflector system. <br /> Horn/Strobe Combination <br /> The horn/strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. <br /> The hom/strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Ac[requirements for visible <br /> signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated <br /> lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal(cononuous) <br /> pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on <br /> horn/strobe models shall operete on a coded or non-coded power supply. <br /> Outdoor Products <br /> SpectrAlert Advance outdoor horns,strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 <br /> degrees Fahrenheit.The produtts shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths inch conduit <br /> entries. <br /> Synchronization Module <br /> The module shall be a System Sensor Syno-Cir,-wt model MDL listed to UL 464 and shall be approved for fire protec[ive service.The module shall synchronize <br /> SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn/strobe models over a <br /> single pair of wires.The module shall mount to a 4'�/,e x 4�Y,e x 2Ye-inch back boxThe module shall also control two Style Y(class B)circuits or one Style Z <br /> (class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they <br /> control.The module shall not operate on a coded power supply. <br /> Standard Operating Temperature 32°F to 120°F(0°C to 49°Q <br /> K Series Opereting Tempereture -40°F to 151°F(-40°C to 66°C) <br /> Humidity Range 10 to 93%non-condensing(indoor products) <br /> Strobe Flash Rate i flash per second <br /> Nominal Voltage Regulated 12DUFWR or regulated 24DGFWR' <br /> Operating Voltage RangeZ 8 to 17.5 V(12V nominal)or 16 to 33 V(24 nominaD <br /> Inputterminal wire gauge 12 to 18 AWG <br /> Ceiling mount dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) <br /> Wall mount dimensions(including lens) 5.61 x 4.7'W x 2.5"D(142 mm l x 119 mm W x 64 mm D) <br /> Horn dimensions 5.6"L x 4.7'W x 1.3'D(142 mm L x 119 mm W x 33 mm D) <br /> Wail-mount back box skirt dimensions(BBS-2,BBSW-2) 5.91 x:.OIN x 2.��D(7 51 mm L x 128 mm W x 56 mm D) <br /> Ceiling-mount back box skirt dimensions(BBSC-2,BBSCW-2) 71"diameter x 2.25"high(180 mm diameter x 57 mm high) <br /> Wall-mount weatherproof back box dimensions(SA-WBB) 5.7"L x 5.1 W x 2.0"D(145 mm L x 130 mm W x 51 mm D) <br /> Ceiling-mount weatherproof back box dimensions(SA-WBBC) 71"diameter x 2.0"high(180 mm diameter x S 1 mm high) <br /> Notes: <br /> 1 Full Wave Rectified(FWR)voltage is a non-regulated,time varying power source that is used on some power supply and panel outputs. <br /> 2.P,5,PC,and SC produc[s will operate at 1�V nominal only for 1 S and 15/75 cd. <br /> A05-0395-003 <br />