Laserfiche WebLink
DN-7101.A•A1-110 <br /> FireWarden-100-2�E� (1 N OTI F 1 E R° <br /> Intelligent Addressable FACP � <br /> with Bui�t-In Communciator by H o n eywe I I <br /> General <br /> The Notifier FireWarden-100-2 (NFW2-100) is a combination - <br /> � FACP (Fire Alarm Control Panel) and DACT (Digital Alarm <br /> Communicator/Transmitter) all on one circuit board.This com- � <br /> pact intelligent addressable conVOl panel has an extensive list <br /> of powerFul features. <br /> The SLC (Signaling Line Circuit) of the FireWarden-100-2 <br /> operates using a Rapid Group Polling communication protocol <br /> technology that polls multiple devices simultaneously for a <br /> quicker device response time.This patented technology allows <br /> a fully-loaded panel with up to 198 devices to report an inci- <br /> dent and activate the notification circuits in under 10 seconds. i <br /> With this improved polling, devices can be wired on standard <br /> twisted,unshielded wire up to a distance of 10,000 feet. (Con- <br /> sult the wire table on page 3 for specific installation instruc- <br /> tions.) <br /> The FireWarden-100-2's quick-remove chassis protects the <br /> electronics during construction. The backbox can be installed <br /> allowing field wiring to be pulled. When construction is com- <br /> pleted, the electronics can be quickly installed with just two <br /> bolts. <br /> Available accessories include LED, graphic and LCD annunci- � <br /> ators,and reverse polarity/city box transmitter <br /> The panel is programmed through the FACP's keypad or via a � <br /> standard PS-2 computer keyboard, which can be plugged <br /> directly into the printed circuit board.This permits easy typing <br /> of address labels and other programming information. • System alarm verification selection per detector point. <br /> NOTE:Unless otherwise specified,the terms FireWarden-100-2 is ' PAS (Positive Alarm Sequence) and presignal delay per <br /> used in this document to refer to both the FireWarden-f00-2 and point(NFPA 72 compliant). <br /> the FireWarden-100-2E FACPs(Fire Alarm Control Panels). NOTE:Only detectors may participate in PAS. <br /> Features SLC LOOP: <br /> • SLC can be configured for NFPA Style 4, 6,or 7 operation. <br /> • Listed to UL standard 864,9th edition. • SLC supports up to 198 addressable devices per loop (99 <br /> • On-board DACT. detectors and 99 monitor,conVOl,or relay modules). <br /> • Four Style Y (Class B) or two Class A (Style Z) NAC cir- . SLC loop maximum length 10,000 ft. (3,000 m.) <br /> cuits. See wire table on page 3. <br /> • Selectable strobe synchronization for System Sensor, NOTIF/CATION APPLIANCE CIRCUITS NACS: <br /> Wheelock,and Gentex devices. � � <br /> • Remote Acknowledge,Silence, Reset and Drill via address- ' Four onboard NACs with additional NAC capability using <br /> able monitor modules. output control modules(NC-100). <br /> • Up to 32 annunciators or remote annunciators via EIA- ' Silence Inhibit and Auto Silence timer options. <br /> 485 • Continuous, March Time, Temporal or California code for <br /> • EIA-232 printer/PC interface (variable baud rate) on main main circuit board NACs with two-stage capability. <br /> circuit board. • Selectable strobe synchronization per NAC. <br /> • Integral 80-character LCD display with backlighting. • 2.5 amps maximum per each NAC circuit. <br /> • Real-time CloCk/calendar with automatiC daylight savings NOTE:Maximum or total 24VDC system power shared between <br /> control. all NAC circuits and auxiliary power outputs is 3.6 amps. (System <br /> • Detector sensitivity test capability(NFPA 72 compliant). Powerincreases to 6.6 amps with optional XRM-24 transformer.) <br /> • History file with 1,000-event capacity. PROGRAMMING AND SOFTWARE: <br /> • Maintenance alert warns when smoke detector dust accu- • Autoprogram(learn mode)reduces installation time. <br /> mulation is excessive. • Custom English labels(per point)may be manually entered <br /> • Automatic device type-code verification. or selected from an internal library file. <br /> • One person audible or silent walk test with walk-test log and • Two programmable Form-C relay outputs. <br /> printout. • 99 software zones. <br /> • Point trouble identification. • Continuous fire protection during online programming at the <br /> • Watertlow(nonsilenceable) selection per monitor point. front panel. <br /> DN-7101.A•09l21/07—Page 1 of 4 <br />