. . - . - . <br /> Wall Mount or Ceiling Mount,Common Specifications <br /> Rated Voltage Range Regulated 24 VDC,see Note 1 below <br /> Flash Rate 1 Hz <br /> Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC <br /> Temperature Range 32°to 122°F(0°to 50°C) <br /> Humidity Range 10%to 93%, non-condensing at 100° F(38°C) <br /> Connections Terminal blocks for 18 AWG to 12 AWG(0 82 mm2 to 3.31 mm2),two wires per <br /> terminal for inlout wiring <br /> Housing Dimensions(with lens) 5-1/8" H x 5"W x 2-3/4" D(130 mm x 127 mm x 70 mm) <br /> Wall Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd <br /> Strobe Setting(see Note 2 below) 60 mA 94 mA 186 mA 252 mA <br /> Mount <br /> Reference RMS Currents 18 VDC 53 mA 84 mA 165 mA 224 mA <br /> at other voltages 24 VDC 40 mA 63 mA 124 mA 168 mA <br /> Housing Dimensions(with lens) 4-3/4"L x 2-5/16"W x 2-5/8" D(121 mm x 75 mm x 67 mm) <br /> Ceiling Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd <br /> Mount Strobe Setting(see Note 2 below) 75 mA 125 mA 233 mA 316 mA <br /> Reference RMS Currents 18 VDC 67 mA 111 mA 207 mA 281 mA <br /> at other voltages 24 VDC 50 mA 83 mA 155 mA 211 mA <br /> NOTES: <br /> 1 "Regulated 24 VDC"refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devic:es for the Hearing <br /> Impaired, changes effective May 1, 2004 This voltage range is the absolute operating range. Operation outside of this range <br /> may cause permanent damage to the strobe. Please note that 16 VDC is the lowest operating voltage that is allowed at the last <br /> appliance on the NAC under worst case conditions. <br /> 2. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage�and the maximum RMS <br /> current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a <br /> varying current waveform) <br /> . - - . • . <br /> L� L� L� <br /> 0 0 <br /> Mounting is compatible with / \ o / \ r <br /> single gang,double gang,and � � � � <br /> 4"(102 mm)square boxes, o 0 0 o a <br /> 1-1/2"(38 mm)deep,by others o � o o IMPORTANT!WALL MOUNT <br /> INSTALLATION HEIGHT REFERENCE <br /> Bottom of lens <br /> a o QTM�s� � is either even <br /> UP with, or slightly Electrical <br /> Wiring access hole � above bottom box outline <br /> OO � of compatible - <br /> boxes <br /> $ � � 1 <br /> Wiring terminals a o <br /> �.�..�.�,\_._..:__.�......__ ... <br /> �, � R � Mounting Holes: <br /> ����� �� , � 4"square(4) NFPA 72 requires 80"(2.03 m) <br /> -- Single gang(2) that the entire lens minimum <br /> Double gang(3) be not less than <br /> 80"and not greater <br /> than 96"above the <br /> Transparent housing <br /> finished flc�or <br /> and lens assembly <br /> Intensity selection <br /> plug,accessible only <br /> from rear of housing; '�s <br /> � � � � factory setting is 15 cd <br /> IJ Ll <br /> Removable cover Strobe intensity <br /> (tool required) viewing slot <br /> 3 S4906-0001-4 9/2009 <br />