My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
12-12736
Zephyrhills
>
Building Department
>
Permits
>
2012
>
12-12736
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/25/2013 1:19:24 PM
Creation date
1/25/2013 1:16:36 PM
Metadata
Fields
Template:
Building Department
Company Name
FLORIDA HOSPITAL OF ZEPHYRHILLS
Building Department - Doc Type
Permit
Permit #
12-12736
Building Department - Name
FLORIDA HOSPITAL ZEPHYRHILLS
Address
7050 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
,SimplexGrinn�e// <br /> A7"yca International Campany <br /> SCOPE OF WORK <br /> ; SimplexGrinnell is renovating the existing fire alarm system.System includes a new smoke detectors,v � <br /> duct detector,and strobes. <br /> ; Installation of peripheral devices shall be per NFPA 72 and the following guidelines. <br /> � ' <br /> Ceilin�Smoke and Heat Detectors: A Smoke detectors shall be as shown on the shop drawings, no <br /> further than 21 feet from any wall and,if wall-mounted,between 4-10 inches from top of device to the <br /> �: ceiling. <br /> Duct Smoke Detectors: Duct detectors shall be 4-wire devices and provided for units that gener�ate <br /> over 2,000 cubic feet per minute(c.f.m.)airflow. One duct detector shall be provided and mounted on <br /> the supply duct per NFPA-90A. <br /> Notification Appliance Devices: Chime/strobes, and strobes will be provided. The chime/strobes and <br /> strobes shall be mounted in the wall and in locations as shown on the shop drawings.All strobe candela , <br /> shall be sized per NFPA-72. <br /> , Theory , <br /> ; This system shall operate existing conditions,as follows: � <br /> Upon activation of a manual pull station or automatic detector the system shall: <br /> activate an audible alarm tone and alarm LED on the FACP , <br /> � activate all designated chime and strobe circuits(on until silence) <br /> ' shutdown all AHU's via the 4-wire duct detectors � <br /> � automatically dial the Owner-contracted UL-listed central monitoring station ' <br /> ! Should a circuit go out of service (i.e.short-or open-circuit,ground,etc.),the system shall: <br /> activate an audible trouble tone and trouble LED on the FACP <br /> ; automatically dial the Owner-contracted UL-listed central monitoring station <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.