My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
12-12786
Zephyrhills
>
Building Department
>
Permits
>
2012
>
12-12786
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/28/2013 12:43:21 PM
Creation date
1/28/2013 12:43:17 PM
Metadata
Fields
Template:
Building Department
Company Name
CHILI'S BAR & GRILL
Building Department - Doc Type
Permit
Permit #
12-12786
Building Department - Name
CHILI'S BAR & GRILL
Address
7643 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
General Bulletin No. 4260 <br /> • May 23, 2000 <br /> Page 2 <br /> • For PIRANHA installations utilizing sprinkler systems in new construction, the PIRANHA water demand must <br /> be calculated as part of the sprinkler system demand (if the point of connection is to be in the hydraulically <br /> most remote area). The water demand for each PIRANHA system nozzle, regardless of nozzle quantity is <br /> -$ 9Pm. <br /> The pressure loss in the piping, valves, and fittings from the sprinkler connection to the ANSUL AUTOMAN <br /> Regulated Release Assembiy and/or Regulated Actuator Assembly(s) must be included in the hydraulic <br /> caiculations. In new construction, the PIRANHA wateriine piping can be connected to the nearest branch <br /> line provided the hydrauiic calculations indicate an adequate water supply. <br /> • For PIRANHA waterline connection to existing sprinkler piping outside the hydraulically most remote area, <br /> connection can be made to either the nearest cross main or a sprinkler branch line. (See Figure 1, 1 a,). For <br /> PIRANHA waterline connection to existing sprinkler piping within the hydraulically most remote area, the <br /> PI RANHA dedicated waterline must be connected to the nearest"cross main", (See Figure 1, 1 b,) unless the <br /> sprinkler system can be hydraulically recalculated to verify enough water pressure and flow to allow <br /> connection to a sprinkler branch (ine (See Figure 1, 1 c). <br /> • The PIRANHA ANSUL AUTOMAN Regulated Release Assembly and Regulated Actuator Assembly are <br /> listed for use with water pressures up to and incfuding 100 psi. When the calculated static pressure at the <br /> inlet to either the ANSULAUTOMAN Regulated Release or Regulated Actuator does not exceed 100 psi, the <br /> PIRANHA dedicated waterline must include a lockable water shutoff valve, wye strainer, and low point drain <br /> valve (1 inch minimum). (See Figures 2 and 3). <br /> • When the water pressure at the inlet to either the ANSUL AUTOMAN Regulated Release Assembly or <br /> Regulated Actuator Assembly exceeds 100 psi static pressure,the PI RANHA dedicated waterline will require <br /> a primary shutoff valve, a pressure regulating (reducing) valve (to lower the pressure to below 100 psi), and <br /> a pressure relief valve piped to a drain, in addition to the ANSUL lockable shutoff valve, wye strainer, and low <br /> point drain valve. (See Figures 4 & 5). <br /> The ANSU L Lockable Ball Valve is available by ordering either the 1 inch valve (P/N 423956), or the 1 1/4 <br /> inch vafve (P/N 423957), along with Padlock (P/N 423727), and Water Valve I.D. Tag (P/N 423678). The ball <br /> valve must be installed in an accessible location that is clearfy visible, if possible. If the valve is <br /> installed in an enclosure or above the ceiling its location must be identified by an easily located <br /> nameplate or placard. ' <br /> You may aiso want to consider addirg a 3/4 inch union above the ANSl.�L Al!TrJMAh Regulated Release <br /> and each Regulated Actuator Assembly connected to the dedicated PIRANHA waterline, to facilitate <br /> servicing the system. <br /> Should you have questions regarding this bulletin please contact your domestic District Manager, International <br /> Area Manager, or Distributor Technical Services in Marinette, Wisconsin at (715) 735-7411 or (800) 862-6785. <br /> PIRANHA... Taking a Bite Out of the Competition! <br />
The URL can be used to link to this page
Your browser does not support the video tag.