Laserfiche WebLink
cFCTlrJN IV–SYSTEM DESIGN <br /> UL EX. 5174 10-31-97 Page 4-10 <br /> DETECTION SYSTEM REQUIREMENTS <br /> Once fhe fire suppression system design has been determined, a Detector Placement Requirements <br /> detection system design must be completed.This section contains EXHAUST DUCTS <br /> guidelines and limitations for the detection system. <br /> Each exhaust duct must have at least one detector instalied in the <br /> Detector ldentification duct entrance, located in the airstream of the cooking vapors,or at <br /> The two types of detectors are distinguished from each other by a maximum of 20 ft. (6 1 m) into the duct opening See Figure 18 <br /> their location in the detection system. <br /> 1 The Terminal Detector(Part No 15375, or 417368) is the last <br /> in a series of detectors, or the only detector used in a single- �_�_� <br /> detector system.This detector is thus named because it is at =—=ii � � �-=-=_= <br /> the point at which the wire rope ends, or"terminates" <br /> 2.A Series Detector(Part No 15373,or 417369)is any detector <br /> located in-line between the regulated release mechanism and I <br /> the terminal detector zo Fr.�s m� <br /> MAXIMUM <br /> Detector/Pulley Elbow Quantity <br /> The quantity of detectors used in the system wiil vary depending <br /> on the style of detector used. <br /> 1 Conduit runs,puliey elbows,and number of detectors per sys- <br /> tem must be within the approved system parameters.The fol- <br /> lowing requirements must not be exceeded: <br /> Maximum Maximum Maximum —_—_ - - - --- <br /> Number of Number of Length of 1/2 <br /> Detectors Elbows in. Conduit FIGURE 18 <br /> per System �er Skstem �er System '�"��' <br /> Hinge Style 5 8 103 ft. (31 3 m) NOTICE <br /> Detector When gas appliances are used and the flue <br /> gases from the burner are exhausted into the <br /> Scissors Style 15 20 150 ft. (45 7 m) duct, the detector must be kept out of the air <br /> Detector stream of these exhaust gases. These gases <br /> 2. If hinge style detectors are mixed in a system with scissor can be very hot and could actuate the system <br /> style,4 series and 1 terminal is the maximum number allowed unnecessarily <br /> 3 If hinge style detectors are mixed in a system with scissor Duct openings that are long and narrow or large <br /> style, the maximum length of wire rope must not exceed 1 Q3 enough to require multiple duct nozzles may <br /> ft. (31 4 m) and the maximum number of puiley elbows must require additional detectors. <br /> not exceed 8. ELECTROSTATIC PRECIPITATOR <br /> If an electrostatic precipitator is located at or near the base of the <br /> exhaust duct, it is necessary to locate a detector below the pre- <br /> cipitator, at the base of the duct, and also locate one in the duct. <br /> just above the precipitator. See Figure 19 <br /> When installing the detector bracket and system conduit, make <br /> certain they do not interfere with the operation of the precipitator <br /> � <br /> , <br /> i <br /> � <br /> � <br /> FIGURE 19 <br /> �CJ?68 <br />