Laserfiche WebLink
Limitations <br /> 1. This product has been evaluated and is in compliance with the 2007 Florida Building Code <br /> structural requirements excluding the "High Velocity Hurricane Zone". <br /> 2. Product anchors shall be as listed and spaced as shown on details. Anchor enibedinent to <br /> base material shall be beyond wall dressing or stucco. <br /> 3. When used in areas requiring wind borne debris protection, this product is re��uired to be <br /> protected with an impact resistant covering that complies with Section 1609.1.2 of the <br /> Florida Building Code. <br /> 4. For through the frame anchoring in 2a stud framing construction, anchoring oi'these units <br /> shall be the same as that shown for 2x buck masonry construction. <br /> 5. Site conditions that deviate from the details of drawing FL-5702.1 reqizire further <br /> engineering analysis by a licensed engineer or registered architect. <br /> 6. See drawing FL-5702.1 for size and design pressure limitations. <br /> � <br /> Lyndon F. Schmidt,P.E. <br /> FL No 43409 <br /> December 16,2008 <br /> PF861 Sheet 2 of 3 <br />