My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
12-12801
Zephyrhills
>
Building Department
>
Permits
>
2012
>
12-12801
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/28/2013 1:03:56 PM
Creation date
1/28/2013 12:59:33 PM
Metadata
Fields
Template:
Building Department
Company Name
FLORIDA MEDICAL CLINIC
Building Department - Doc Type
Permit
Permit #
12-12801
Building Department - Name
FLORIDA MEDICAL CLINIC
Address
38135 MARKET SQUARE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
s SYSTEM SPECIFICATIONS <br /> . System Capacity its peripherals be installed in an environment with a normal room <br /> temperature of 15–27°C/60–80°F. <br /> • Intelligent Signaling Line Circuits.... ........... ......... .........1 <br /> • Intelligent detectors ................. ... ......... ...................159 Agency Listings and Approvals <br /> • Addressable monitor/control modules................... .......159 <br /> Programmable internat hardware and output circuits .........4 The listings and approvals below apply to the basic NFS-320 <br /> � control panel.In some cases,certain modules may not be listed <br /> • Programmable software zones ........ ... ..........................99 by certain approval agencies,or listing may be in process.Con- <br /> • Special programming zones...... .................. ....... 14 sult factory for latest listing status. <br /> • LCD annunciators per NFS-320/-320E ................ ........32 • UL Listed:S635. <br /> • ACS annunciators • ULC Listed:S635(NFS-320C only,excludes IPDAC�. <br /> per NFS-320/-320E .......................32 addresses x 64 points . FM Approved. <br /> Specifications • CSFM:7165-0028:0243. <br /> • MEA:128-07-E. <br /> • Primary input power • FDNY:COA#6085. <br /> —NFS-320:120 VAC,50/60 Hz,5.0 A. • City of Chicago.' <br /> —NFS-320E:220/240 VAC,50/60 Hz,2.5 A. NOTE: For additional informafion on UL- and ULC-listed model <br /> • Total output 24 V power:6.0 A in alarm. NFS-320C,see DN-60085. For informahon on NFS-320SYS, see <br /> NOTE: The power supp/y has a tota/of 6.0 A of available power. DN-60637. <br /> This is shared by all interna/circuits. When used with the MARINE-EQ, appropriate seismic bracket, <br /> • Standard notification circuits(4): 1.5 A each. and marine approved devices, these ONYX fire alarm control <br /> • Resettable regulated 24V power• 1.25 A. panels are approved by the following agencies: <br /> • Two non-resettable regulated 24V power outputs: • US Coast Guard: 1 fi1.002/50/0(Standard 46 CFR). <br /> —1.25 A. • Lioyd's Register: 1 1/6000 1 3(ENV;3 category). <br /> -o.so,a. Standards <br /> • Non-resettable 5V power�0.15 A. <br /> • Battery charger range: 18 AH—200 AH. Use separate cabi- The NFS-320 complies with the following UL Standards and <br /> net for batteries over 26 AH. NFPA 72,IBC,and CBC Fire Alarm Systems requirements: <br /> • Float rate:27.6 V. • UL 864(Fire). <br /> • UL 1076(Burglary). <br /> Cabinet Specifications • LOCAL(Automatic, Manual, Waterflow and Sprinkler Super- <br /> NFS-320 cabinet dimensions: visory). <br /> • Backbox: 18.12 in. (46.025 cm)width; 18.12 in. (46.025 cm) � AUXILIARY (Automatic, Manual and Watertlow) (require's <br /> height;5.81 in.(14.76 cm)depth. TM-4). <br /> • Door• 18.187 in. (46.195 cm) width; 18.40 in. (46.736 cm) ' REMOTE STATION (Automatic, Manual, Watertlow and <br /> height;0.75 in.(1.905 cm)depth. Sprink�er Supervisory)(requires TM-4). <br /> • Trim ring:Molding width is 0.905 in.(2.299 cm). • PROPRIETARY(Automatic,Manual,Waterflow and Sprinkler <br /> Supervisory).Not applicab/e for FM. <br /> • Shipping weight(without batteries):36.15 Ib.(16.4 kg). . CENTRAL STATION (Automatic, Manual, Watertlow and <br /> Sprinkler Supervisory)(requires UDAC�. <br /> Temperature and Humidity Ranges . EMERGENCY VOICE/ALARM. <br /> This system meets NFPA requirements for operation at 0 — • OT, PSDN (Other Technologies, Packet-switched Data Net- <br /> 49°C/32—120°F and at a relative humidity 93%f 2%RH(non- work). <br /> condensing) at 32°C t 2°C (90°F t 3°F). However, the useful . IBC 2000,IBC 2003,IBC 2006,IBC2009(Seismic). <br /> life of the system's standby batteries and the electronic compo- . CBC 2007(Seismic). <br /> nents may be adversely affected by extreme temperature ranges <br /> and humidity. Therefore,it is recommended that this system and <br /> NOTI•FlRE•NETT"",Intelli�uadTM',and ONYXWorksTM'are trademarks;and <br /> Acclimate�PIUST'", FlashScar�, NOTIFIER�, ONYX�, VeriFlre�, and <br /> VIEW�are registered trademarks of Honeywell International Inc.Mlcrosoit� <br /> and Windows�are registered trademarks of Microsoft Corporation.18N1�Is <br /> a registered Vademark of IBM Corporation. <br /> �Y2011 by Honeywell Intemational Inc.All rlghts reserved.Unauthorized use <br /> of thfs document is stricUy prohiblted. <br /> '�O �oo� This document is not intended to be used for installation purposes. <br /> We try to keep our product information up-to-date and accurate. <br /> We cannot cover all specific applications or anticipate all requirements. <br /> �d������ All specifications are subject to change without notice. <br /> QUALITY SYSTEMS MadeintheU.S.A. <br /> For more information,contact Notifier.Phone:(203)484-7161,FAX.(203)484-7118. <br /> www.notifier.com <br /> Page 6 of 6—DN-7112:G•12/19/2011 <br />
The URL can be used to link to this page
Your browser does not support the video tag.