My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
12-12894
Zephyrhills
>
Building Department
>
Permits
>
2012
>
12-12894
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2013 11:46:52 AM
Creation date
2/6/2013 11:46:47 AM
Metadata
Fields
Template:
Building Department
Company Name
CITY OF ZEPHYRHILLS
Building Department - Doc Type
Permit
Permit #
12-12894
Building Department - Name
CITY OF ZEPHYRHILLS
Address
5335 8TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
72
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Zephyrhills Fire Rescue <br /> G��U7 Dairy Road, .7..eph�-rhills, TL ���42 <br /> F'irc C'hicf E3u:, (813 j 7�i0-OU41 <br /> Keith Williains Fa� (813) 7$f)-(1044 <br /> 13 March 2012 _ _.. �_.� u_.�.._... __... .__._. .._. ,..,_._�,d�_, ...�_e.._.__..��.......�.._.. <br /> Plan Number 12-013 <br /> Project: Renovation of Mechanical and Electrical at Zephyrhills City Hall, 5335 8th Street <br /> Number of Pages: 9, with supporting documents for lighting and plumbing devices <br /> � Date received: by this Office 03-12-2012 <br /> _ This Officer has reviewed the plans for the renovation to the mechanical and electrical <br /> system at Zephyrhills City Hall and Public Library, 5335 and 5347 8t" Street Zephyrhills. <br /> Following the review, a conditional approval to proceed is given. Fees are waived as this <br /> is a City of Zephyrhills project. The following items shall be considered: <br /> 1. Smoke detectors in the mechanical duct work in both buildings shall be <br /> connected to their respective existing Fire Alarm system. <br /> 2. Modification to the existing Fire Alarm system shall be performed by a <br /> licensed Fire Alarm Contractor. (State Alarm is the current vendor for all City <br /> of Zephyrhills fire alarm systems). <br /> 3. Existing exit lights are being replaced with LED exit lights, if Emergency <br /> lights are included in this renovation or currently a combination <br /> Exit/Emergency light unit they shall be inspected during final inspection. <br /> Inspections Required: <br /> 1. Final inspection and Fire Alarm test to insure connectivity between <br /> mechanical and alarm system. <br /> Review and approval of the submitted plans does not relieve the contractor from the <br /> responsibility of correcting any deficiencies noted during inspection. <br /> Respectfully submitted on 13 March 2012 by, <br /> ���f��-� <br /> Keith A. Williams, EFO, CFO, CMO, MIFireE <br /> Fire Chief <br /> Fire Safety Inspector, #148104 <br />
The URL can be used to link to this page
Your browser does not support the video tag.