My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
12-12989
Zephyrhills
>
Building Department
>
Permits
>
2012
>
12-12989
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2013 1:28:18 PM
Creation date
2/12/2013 1:28:17 PM
Metadata
Fields
Template:
Building Department
Company Name
CHALFONT VILLAS
Building Department - Doc Type
Permit
Permit #
12-12989
Building Department - Name
ROBERTS,RICHARD & JOAN
Address
4773 SILVER CIR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Pro ect Summarv Job: <br /> � ���t��+���f�� � 'J Date: 4/18/2012 <br /> ��� � Entire House By: Bruce Jones <br /> Bruce Jones Air Conditionig <br /> 5509 Ike Smith Road,Plant Crty,FL 33565 Phone�813986-0264 Fax 813-986-8020 Email:brucesa�r@wildblue.net Web:www.brucepnesair com License:CAC056720 <br /> � • ' • • <br /> For� Joan Roberts <br /> 4773 Silver Circle,Zephyrhills, FL <br /> Phone. 813-780-2836 <br /> Notes. <br /> � - • • • <br /> Weather Tampa, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 41 °F Outside db 91 °F <br /> Inside db 70 °F Inside db 75 °F <br /> Design TD 29 °F Design TD 16 °F <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 56 grllb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 14018 Btuh Structure 1011 Q Btuh <br /> Ducts 3177 Btuh Ducts 4919 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 17195 Btuh Use manufacturer's data <br /> Rate/swing multiplier 1 OOY <br /> Infiltration Equipment sensible load 15029 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Average <br /> Fireplaces 0 Structure 1967 Btuh <br /> Ducts 971 Btuh <br /> Heating Cooling Central vent(0 cfm) 0 Btuh <br /> Prea(ftz) 750 750 Equipment latent load 2938 Btuh <br /> Vblume(fN) 6750 6750 <br /> Ai r changes/hour 0 61 0.32 Equipment total load 17966 Btuh <br /> Equiv AVF(cfm) 69 36 Req.total capacity at 0 70 SHR 1 8 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make American Standard Make American Standard <br /> Trade Trade <br /> Model 4A6Z0024A1 Cond 4A6Z0024A1 <br /> AHRI ref no 4385831 Coil AM8AOB30V21 <br /> AHRI ref no 4385831 <br /> Efficiency 0 HSPF Effciency 19 SEER <br /> Heating input Sensible cooling 0 Btuh <br /> Heating output 0 Btuh @ 47°F Latent cooling 0 Btuh <br /> Temperature rise 0 °F Total cooling 0 Btuh <br /> Actual air flow 610 cfm Actual air flow 610 cfm <br /> Air flow factor 0 035 cfm/Btuh Air flow factor 0 041 cfm/Btuh <br /> Static pressure 0 in H20 Static pressure 0 in H20 <br /> Space thermostat Load sensible heat ratio 0 84 <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> ��,� M���, 2012-Apr-18 01 28.22 <br /> Q Right-Sude�U nrversal 2012 12 0 04 Right J�Nbbile Page 1 <br /> '�`!�C 1WINDOWS\TEMP\wstmp\OddSdaeb-adbf-4030-bc343cd43249c161.rup Calc=MJ8 Front Door faces. N <br />
The URL can be used to link to this page
Your browser does not support the video tag.