' DF-52416:D•A3-20 <br /> � MS-SUD�E)/MS-10UD(E) Series , F��.��Te�A�arms <br /> Five Zone Fire Alarm Control Panel <br /> , Ten Zone Fire Alarm Control Panel by Honeywell <br /> General <br /> The MS-5UD-3(E) is a five-zone FACP (Fire Alarm Control <br /> Panel)and the MS-10UD-7(E)is a ten-zone FACP These con- <br /> trol panels provide reliable fire signaling protection for small to <br /> medium-sized commercial, industrial, and institutional build- <br /> ings. Both panels include built-in communicators for Central <br /> Station Service and remote upload/download. I��,,,pl,�„., �,,, ��-� <br /> Each of these FACPs is compatible with System Sensor's <br /> microprocessor-based i3 series detectors. These conventional <br /> smoke detectors can transmit a maintenance trouble signal to <br /> the FACP indicating the need for cleaning and a supervisory <br /> "freeze" signal when the ambient temperature falls below the <br /> detector rating. Additionally, both the MS-5UD-3 and MS- <br /> 10UD-7 are compatible with conventional input devices such <br /> as two-and four-wire smoke detectors,pull stations,waterflow <br /> devices, tamper switches, and other normally-open contact g <br /> devices. Refer to the Fire•Lite Device Compatibiliry Document s <br /> for a complete listing of compatible devices. Y <br /> Outputs include four NACs (Notification Appliance Circuits), " <br /> three programmable Form-C relays (factory programmed for <br /> Alarm,Trouble,and Supervisory)and 24 VDC special applica- <br /> tion resettable and nonresettable power outputs. The FACPs <br /> supervise all wiring, AC voltage, battery level and telephone _Strobe Synchronization for System Sensor, Wheelock, <br /> line integrity. Gentex, Faraday,or Amseco devices. <br /> Activation of a compatible smoke detector or any normally- –Selective Silence(horn-strobe mute) <br /> open fire alarm initiating device will activate audible and visual <br /> signaling devices, illuminate an indicating LED, sound the –Temporal or Steady Signal. <br /> piezo sounder at the FACP, activate the communicator and –Silenceable or Nonsilenceable. <br /> FACP alarm relay, and operate an optional module used to • Optional CAC-5X Style Z (Class A) Converter Module for <br /> notify a remote station or initiate an auxiliary control function. NACs and IDCs(2 required for MS-10UD-7) <br /> New options include a UL listed printer, PRN-6F and FireLite's • Form-C Relays for Alarm, Trouble and Supervisory - Con- <br /> IPDACT Internet Monitoring module. The FireWatch Series tact Ratings 2.0 AC� 30 VDC or O.S A � 30 VAC(resistive) <br /> internet monitoring modules IPDACT-2 and IPDACT 2UD per- . 3.0 A total system current for MS-5UD-3. <br /> mit monitoring of alarm signals over the Internet saving the 7 0 A total system current for MS-10UD-7 <br /> monthly cost of two telephone lines.Although not required,the � <br /> secondary telephone line may be retained providing backup • Optional Dress Panel DP-51050 <br /> communication over the public switched telephone line. • Optional Trim Ring TR-CE for semi-flush mounting. <br /> NOTE: The MS-5UD-3E and MS-l0UD-7E offers the same fea- • 24 volt operation. <br /> tures as the MS-5UD-3 and MS-10UD-7 but allow connection to . Low AC voltage sense. <br /> 240 UAC. Unless othenvise specified, the information in this data Alarm VerifiCation <br /> sheet applies to both the 120 VAC and the 240 VAC versions of � <br /> these panels. • PAS(Positive Alarm Sequence). <br /> NOTE:For ULC-listed models,see DF-60440 • Automatic battery trickle charger <br /> • Up to eight ANN-BUS annunciators: <br /> FeatureS –Optional 8 zone Relay Module ANN-RLY <br /> • Listed to UL Standard 864,9th edition –Optional LED Annunciator Module ANN-LED, <br /> • Built-in DACT(Digital Alarm CommunicatorlTransmitter) –Optional Remote Annunciator ANN-80 <br /> • Style B(Class B) IDC(Initiating Device Circuit) –Optional Remote Printer Gateway ANN-S/PG <br /> –MS-5UD-3-five IDCs. –Optional LED Annunciator Driver ANN-I/O <br /> –MS-10UD-7-ten IDCs. • Optional 4XTMF module (conventional reverse polarity/city <br /> • Style Y(Class B)NAC(Notification Appliance Circuit)-spe- box transmitter) <br /> cial application power PROGRAMM/NG AND SOFTWARE: <br /> –MS-5UD-3-four NACs. • Can be programmed at the panel with no special software <br /> –MS-10UD-7-four NACs. or additional equipment. <br /> • Notification Appliances may be programmed as • Programmable Make/Break Ratio. <br /> –Silence Inhibit. • Upload/Download(local or remote)of program and data via <br /> –Auto-Silence. integral DACT <br /> DF-52416:D•07l26/2010—Page 1 of 4 <br />