<br /> UL(TST 1740) ASTM D3161, D7158, D3462 11CA47919 12/03/2011�
<br /> UL(TST 1740) ASTM D3161, D7158, D3462 11CA48408 12/OS/2011
<br /> UL(TST 1740) ASTM D3161, D7158, D3462 11CA48725 12/09/2011
<br /> UL(QUA 1743) Quality Control Inspection Report, File No. R21 05/17/2011
<br /> UL(QUA 1743) Quality Control R3915 Current
<br /> 4. PRODUCT DESCRIPTION:
<br /> 4.1 Marquis WeatherMax, Royal Sovereign and Sentinel are a fiberglass reinforced, 3-tab asphalt
<br /> roof shingles.
<br /> 4.2 Camelot, Camelot II / Camelot 30, Capstone, Country Mansion, Country Mansion II, Grand
<br /> Canyon, Grand Sequoia, Grand Slate, Grand Slate II, Monaco, Timberline American Harvest,
<br /> Timberline ArmorShield II, Timberline Natural Shadow, Timberline Natural Shadow Arctic White,
<br /> Timberline HD / Timberline Prestique 30, Timberline Prestique 40 / Timberline Cool Series,
<br /> Timberline Ultra HD/Timberline Prestique Lifetime, Timberline Majestic/ Timberline Majestic 30
<br /> and Woodland are fiberglass reinforced, laminated asphalt roof shingles.
<br /> 4.3 Slateline is a fiberglass reinforced, 5-tab asphalt roof shingle.
<br /> 4.4 SeaI-A-Ridge, SeaI-A-Ridge Armorshield, SeaI-A-Ridge Impact Resistant IR, Ridglass 8, Ridglass
<br /> 10, Ridglass 12 and Timbertex Hip and Ridge are fiberglass reinforced, hip and ridge asphalt
<br /> roof shingles.
<br /> 4.5 ProStart Starter Strip Shingles and WeatherBlocker Starter Strip Shingles are a starter strips for
<br /> asphalt roof shingles.
<br /> 5. LIMITATIONS:
<br /> 5.1 This Evaluation Report is not for use in the HVHZ.
<br /> 5.2 Fire Cfassification is not part of this Evaluation Report; refer to current Approved Roofing
<br /> Materials Directory for fire ratings of this product.
<br /> 5.3 Wind Classification:
<br /> 5.3.1 All GAF shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and
<br /> R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are
<br /> acceptable for us in all wind zones up to Vasd = 150 mph (V,,,t = 194 mph). Refer to Section 6
<br /> for installation requirements to meet this wind rating.
<br /> 5.3.2 All GAF hip & ridge shingles noted herein are Classified in accordance with FBC Tables
<br /> 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for
<br /> us in all wind zones up to Vasd = 150 mph (V„it = 194 mph). Refer to Section 6 for installation
<br /> requirements to meet this wind rating.
<br /> 5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60
<br /> feet or less. Calculations by a qualified design professional are required for conditions outside
<br /> these limitations. Contact the shingle manufacturer for data specific to each shingle.
<br /> 5.4 All products in the roof assembly shall have quality assurance audit in accordance with the
<br /> Florida Building Code and F.A.C. Rule 9N-3.
<br /> 6. INSTALLATION:
<br /> 6.1 Underlayment:
<br /> 6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product
<br /> Approval, or be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4 or
<br /> R905.2.3.
<br /> 6.2 Starter Shingles:
<br /> Exterior Research and Design, LLC. Evaluation Report 01506.01.08-R8
<br /> CertiFcate ofAuthorization#9503 FL10124-R6
<br /> Revision 8: 02/06/2012
<br /> Page 3 of 4