Laserfiche WebLink
FL#: FL 14081.1 RI <br /> Date: 4/16/12 <br /> C�+�`� Enqin��rtnq Pag rt No.�3 of 01-GB-S6P-ER <br /> SpPCidi tl,� Strucfiural Enqinper�nq cBUCK,lnc.Certlfrcate of Authorizdtion#8064 <br /> Performance Standards: The product described herein has demonstrated compliance with: <br /> • U1580-06 — Test for Uplift Resistance of Roof Assemb�tes--with Revisions <br /> through February 1998 <br /> � UL 1897-04—Uplift test for roof covering systems <br /> Standards Equivalency; The UL 580-94, UL 1897-98 standard version used to test the evaluated product <br /> assembly is equivalent with the prescribed standards in UL 58Q-06, UL 1897-04 <br /> adopted by the Florida Building Code 2010. <br /> Code Compliance: The product described herein has demonstrated compliance with Florida Building <br /> Code 2010,Section 1504.3.2. <br /> Evaivat�on Repart This product evaluation is fimited to compfience with the structural requirements <br /> Stope: of the Florida Building Code, as related to the scope section to Florida Product <br /> Approval Rule 9N-3.001. <br /> limitations and . Diaphragm and axial load capacity is outside the scope of thls evaluation. <br /> Conditions of Use: . Scoae of"Limitations and Conditions of Use"for this eva,�uation• <br /> This evaluation report for "Optlonal Statewide Approval" contains technical <br /> documentation, specifications and installation method(s) which include <br /> "Limitations and Conditio�s of Use" throughaut the report in accordance <br /> with Rute 9N-3.005. Per Rule 9N-3.004, the Florida Building Commission is <br /> the authority ta approve products under"Optional Statewide Approvaf". <br /> • Option for aqRiication outside"Limitations and Conditions of Use" <br /> Rule 9N-3.005(1)(e)aAows engineering analysis for"project specific approval <br /> by the local authorities having jurisdiction in accordance with the alternate <br /> methods and materials authorized in the Code". Any modification of the <br /> product as evaluated in this report and approved by the Florida Building <br /> C�mmission is outside the scope of this evaluation and wilt be the <br /> responsibility of o#hers. <br /> � Design of support system is outside the scope of this report. <br /> • Fire Classification is outside the scope of Rule 9N-3, anc� is therefore not <br /> included in this evaluation. <br /> • This evaluation report does not evaluate the use of this product for use in the <br /> High Velocity Hurricane Zone code section.(Dade&Broward Counties) <br /> Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in <br /> accordance witM the Florida Building Code and Rule 9N-3.0005 (3) far <br /> manufacturing under a quality assurance program audited by an approved quality <br /> assurance entity through Ut,LLC (FBC Organization ID#QUA 9625). <br />