Laserfiche WebLink
A•' �i/r- `"l <br /> ��-�... <br /> l` -,�TR1NI�T�Y:�Ro <br /> � <br /> Table 1: Roof Cover Options <br /> Asphait Foam-On Wood Slate or <br /> Underlayment Nail-On 7ile Metal Shakes& Simulated <br /> > . . _.,,,_, .. ,,Shin4les ,,., Tile <br /> _ , . 3h�r.. ��atF <br /> Deck-Armor'" Yes Contact Mfg. N� Cnntact Mfg Contac' Mfo !:ontact Mfg <br /> RoofPro'" Yes No No No Yes Yes <br /> Shingle-Mate'"' Yes No No No No No <br /> Tiger PawT" Yes Contact Mfg. No Contact Mfg. Contact Mfg. Contact Mfg. <br /> VersaShieldp Yes No No Yes Yes Yes <br /> Liberty'^'SBS Base/Ply Yes No No No No No <br /> Ruberoidp SA Base/Ply Yes No No No No No <br /> StormGuardp Yes No No Yes No No <br /> UnderROOf'"`2 Yes Yes Yes No No Yes <br /> See 5.4 1 <br /> UnderRoof'"'HT Yes No No Yes No No <br /> Weather Watch� Yes No No No No No <br /> Weather Watchp XT Yes No No No No No <br /> 5.4.1 "Foam-On Tile" is limited to use of Polyfoam PolyPro AH160 unless tensile adhesion / long <br /> term aging data from an accredited testing laboratory is provided. <br /> 5.5 Aliowable substrates for LibertyTM SBS Self-Adhering Base/Ply Sheet; Ruberoid� SA Base/Ply <br /> Sheet; StormGuard� Leak Barrier; UnderRoof'"^ 2 Leak Barrier, UnderRoof"' HT Leak Barrier; <br /> Weather Watchp Leak Barrier; and Weather Watch� XT Leak Barrier are noted below: <br /> 5.5.1 Direct-Bond to Deck: <br /> ➢ New untreated plywood; <br /> ➢ Existing untreated ASTM D41 primed plywood. <br /> 5.5.2 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI 07320 <br /> does not address wind uplift resistance of all underlayment systems beneath foam-on tile <br /> systems, where the underlayment forms part of the load-path. The following wind uplift <br /> limitations apply to under�ayment systems that are not addressed in FRSA/TRI 07320 and are <br /> used in foam-on tile applications. Maximum Design Pressure is the result of`testing for wind <br /> load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of <br /> design wind pressures. <br /> 5.5.2.1 Maximum Design Pressure = -45 osf. <br /> Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. <br /> Primer: (Optional)ASTM D41 <br /> Underlayment: UnderRoofT"' 2 Leak Barrier, self-adhered <br /> 5.5.3 Bond to Mechanicallv Attached Base Underlayment: <br /> ➢ ASTM D226, Type II felt. <br /> ➢ StormSafeT" Anchor Sheet <br /> For installations under mechanically attached prepared roof coverings, base layer shall be <br /> attached per minimum codified requirements. For installations under foam�-on tile systems, <br /> base layer shall be attached per minimum requirements of FRSA/TRI 07320/8-05 or RAS 120. <br /> 5.5.4 Bond to Other Substrate Tvpes: <br /> ➢ ASTM D41 primed metai (flashing metal, valley metal, etc.) <br /> Exterior Research and Design, LLC. Evaluation Report 01506.04.08-R6 <br /> Certificate of Autho�ization#9503 FL10626-R6 <br /> Revision 6: 12/13/2011 <br /> Page 4 of 11 <br />