My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
12-13317
Zephyrhills
>
Building Department
>
Permits
>
2012
>
12-13317
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/26/2013 9:35:15 AM
Creation date
7/1/2013 2:44:34 PM
Metadata
Fields
Template:
Building Department
Company Name
CROWN CASTLE GT COMPANY LLC
Building Department - Doc Type
Permit
Permit #
12-13317
Building Department - Name
CROWN CASTLE GT COMPANY LLC
Address
38522 A AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
165
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Crown Castle USA, Inc. July 16, 2012 <br /> 285 Ft Self Support Tower Structura/Analysis CCI BU No 816298 <br /> Project Number 012-01232-00,Application 144090, Revision 1 Page 5 <br /> 3.1) Analysis Method <br /> tnxTower(version 6.0.4 0), a commercially available analysis software package, was used to create a <br /> three-dimensional model of the tower and calculate member stresses for various loading cases. <br /> Selected output from the analysis is included in Appendix A. <br /> 3.2) Assumptions <br /> 1) The tower was constructed in accordance with its original design and maintained per the <br /> manufacturer's specifications. <br /> 2) The configuration of antennas, transmission cables, mounts and other appurtenances are as <br /> specified in Tables 1 and 2 and the referenced drawings. <br /> 3) Mount sizes, weights, and manufacturers are best estimates based on photos provided and <br /> determined without the benefit of a site visit by SSOE. <br /> 4) All member connections are assumed to have been designed to meet or exceed the load carrying <br /> capacity of the connected member unless otherwise specified in this report. <br /> 5) All foundation steel reinforcing is assumed to have been designed to meet or exceed the load <br /> carrying capacity of the surrounding soils unless otherwise specified in this report. <br /> 6) All equipment model numbers, quantities, and centerline elevations are as provided in the CCI <br /> CAD package, dated 7/9/12 with any adjustments as noted below. <br /> 7) Caisson reinforcing information was not available, so minimum area of steel was assumed in this <br /> analysis. <br /> This analysis may be affected if any assumptions are not valid or have been made in error. SSOE <br /> Group should be notified to determine the effect on the structural integrity of the tower <br /> 4)ANALYSIS RESULTS <br /> Table 5-Section Ca aci Summa <br /> T� -288-2?9 ---- LAg--- - -- L5x5x1l2 _ 4 -039 87?5 O.a. ?ass <br /> T2v 279=272 _ Leg L5x5x1/2 25 -145 � 12474 1.2 Pass <br /> T3 272_259 Leg ' _1L5x5x1l2 46 -3.48 134.35 2.6 Pass <br /> T4_ 259-247 Leg _ L5x5x1/2 83 -8.64 143.90 6.0 Pass <br /> T5 247-237 Leg L8x8x5l8 120 -15 46 282.60 5�5 Pass <br /> - - --- - - -- -- - - - - -- <br /> 10.8(b) <br /> ---- - - --- - - - - <br /> T6 237-232 Leg L8x8x5/8 141 -22.12 . 388.82 5.7 Pass <br /> �---- - - ---- - --- -- - <br /> T7 'L32-222 Leg L8x8x5/8 162 -26.34 388.82 6.8 Pass <br /> -- - - - -- - - -- --- --- <br /> T$ 222-2�� �e9 L8x8x5/8 199 -35.56 371.04 9'6 Pass <br /> -- ------ --------- - - -- - _ 16.1 (b) <br /> � T9 210-195 Leg L8x8x5/8 235 -49.82 340.41 14 6 Pass <br /> � ---- - --- -- -- -- - -- <br /> I T10 195- 183 Leg L8x8x1 1/8 271 -74 16 642.24 11.5 pass <br /> --- -- 25.2(b) <br /> j-- ---- - - --- - - ---- - - -- - - <br /> T11 183-171 Leg L8x8x1 1/8 310 -96.23 642.24 15.0 Pass <br /> T12 171 -146 Leg L8x8x1 1/8 347 -121 61 380.00 32.0 Pass <br /> - --- - - -- - ---- <br /> ---- - - - - ---- <br /> � T13 146-122 Leg L8x8x3/4 2PL0.5x8 392 -173.29 788.33 22�0 Pass <br /> ,-_ _ ----- --- ----- --- - -- 45.4(b) <br /> � ----- <br /> ' T14 122-96 Leg L8x8x3/4 2PLO.Sx8 461 -224.88 774 14 29� Pass <br /> � - - --- - 44.2(b) <br /> i T15 96-72 Leg L8x8x1 2PL0 75x8 530 -282.00 1097 39 25� Pass <br /> �------- -------- � ) <br /> ----- ----- - 44 3 b <br /> i T16 72-52 Leg L8x8x1 2PL0.625x8 599 -335.25 1046.93 32'0 Pass <br /> � - -- - - - - <br /> 52.6(b) <br /> T17 52-32 � Leg � LSx8x1 2PL0 75x8 680 -381 90 � 1132.32 33� Pass <br /> -----� -- - -- -- - -- --- � 9.8(b <br /> --�---- - -r- --- <br /> 5 ) <br /> T18 32-Q � I ep ! l 8xRx1 2PI 0.875xR 7Fi1 -3$4 41 11R1 17 :i2 5 ; Pacc- -- <br /> tnxTower Report-version 6.0 4 0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.