Laserfiche WebLink
� Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.' � <br /> Advanced Air Solutions Inc. Kline Reside�nce <br /> I ,_Tam�a FL___33634__ _ ____ Pa e 2� I, <br /> --- - ---- , <br /> -- - <br /> - <br /> '�, Pro�ect Report <br /> I' ;General Project Information � ' <br /> Project Title: Kline Residence <br /> � Designed By� Robert Vela <br /> Project Date Monday April 9th 2012 <br /> Client Name Heather Kline <br /> iClient Address 39101 3rd Ave <br /> � Client City� Zephyrhills, Florida 33542-5266 <br /> ' Client Phone. 813-469-0328 <br /> Company Name ACE AMERICAN HOME <br /> Company Representative: ROBERT VELA <br /> Company Address. 6008 JETPORT INDUSTRIAL BLVD <br /> Company City� TAMPA, FL, 33634 <br /> Company Phone 813-445-4818 <br /> Company E-Mail Address. OFFICE@COMFORTISCOOL.COM ' <br /> , Company Website: WWW COMFORTISCOOL.COM , <br /> I <br /> � Design Data � ' <br /> Reference City� Tampa, Florida <br /> Building Orientation: Front door faces South <br /> Daily Temperature Range Medium <br /> Latitude: 28 Degrees <br /> Elevation. 19 ft. <br /> Altitude Factor� 0.999 <br /> Elevation Sensible Adj. Factor• 1 000 <br /> Elevation Total Adj. Factor 1 000 <br /> Elevation Heating Adj Factor- 1.000 <br /> I Elevation Heating Adj Factor: 1.000 '�i <br /> I Outdoor Outdoor Outdoor Indoor Indoor Grains <br /> QAL��1112 Y�tBsd.lk� B�L�Luol B�l�Ei�l Drv Bulb Difference <br /> Winter� 40 37.52 80% n/a 70 n/a <br /> � Summer: 95 77 45% 50% 75 46 � <br /> I Check Figures � I <br /> Total Building Supply CFM� 1,284 CFM Per Square ft. 0 895 " �� <br /> i Square ft. of Room Area. 1,434 Square ft. Per Ton 555 <br /> ' Volume(ft)of Cond Space� (clg ) 11,475 <br /> i " Based on area of rooms being heated or cooled (whichever governs system) rather than entire floor area II <br /> -- -- I <br /> I (Building Loads <br /> Total Sensible Gain: 28,220 Btuh 91 % <br /> Total Latent Gain 2,807 Btuh 9 % I <br /> Total Cooling Required Including Ventilation Air� 31,027 Btuh 2.59 Tons (Based On Sensible+ Latent) I, <br /> ', I Notes -- - ------ — --- ---- - - ----- --- � I� <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. , <br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. � <br /> All computed results are estimates as building use and weather may vary. <br /> 'i Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> �, your design conditions. I, <br /> �� 'I <br /> I <br /> � <br /> � - - <br /> C\Users\Jaosn\Desktop\HEATHER KLINE.rhv Thursday, April 26, 2012, 3 45 PM <br />