FORMS <br /> TABLE 402A <br /> BUILDING COMPONENT PERFORMANCE CRITERIA' INSTALLED VALUES: <br /> U-Factor<0.65 � <br /> wndows(see Note 2): SHGC=0.30 U-Factor= <br /> %ofCFA<=20% SHGC= 3�r-' <br /> S li hts U-Fector c 0.75 %of CFA= 0 <br /> Doors:Exterior door U-Factor U-Factor<0.65 <br /> Floors: Slab-on•grede U-Factor= , <br /> No requirement <br /> Over uncontlitloned s aces see Note 3 q_�3 R-Value=.�, <br /> Walls-6ct.and Adj.(see Note 3): <br /> Frame R•13 <br /> Mass (see Note 3) R-Value= <br /> Interior of wa8: R-7.8 R-Value= ��j <br /> EMeria of wall: R-6 R-Velue= <br /> Ceilings(see Notes 3 8 4) R=30 R-Value= �p Test report <br /> Reflectance 025 <br /> ReflecWnce= Attached? <br /> Air distnbution system(see Note 4) <br /> Ye <br /> Ductwork 8 air hendling unit: <br /> Unconditioned space Not allowed Locetion: <br /> Conditioned space � Attachepd9 <br /> Duct R•value R-value 2 6 YesR�o <br /> Air leakage�n Qn 5 0.03 R-Value= �p <br /> Air conditionin s tems see Note 5 ��- <br /> Heating system SEER=13.0 SEER= <br /> Heat pump(see Note 5) Cooling: SEER=13.0 SEER= I� -� <br /> Heating: HSPF=7.7 HSPF= <br /> Gas furnace � � <br /> AFUE78% AFUE\ <br /> Oil fumace AFUE 78% <br /> Electric resistance:Not allowed(see Note 5) AFUE- <br /> Water heaNng system(storage type) <br /> Eledric(see Note 6): 40 gal:EF=0.92 <br /> Gallons= <br /> Gas fired(see Note 7): 50 gal:EF=0.90 EF= <br /> 40 gal:EF=0.59 Gallons= <br /> Other(describe): 50 gal:EF=0.58 EF= <br /> (1)Each component present in the As Proposed home must meet or eacceed each of the applicable pertormance crileria in orderto comply with this code using this method; <br /> othenvise Section 405 compliance must be used. <br /> (2)Windows and doors qualifying as giazed fenestration areas must compiy with both the maximum U-Factor and the maxi mum SHGC(solar Heat Gain Coefficient)criteria <br /> and have a maximum total window area equal to or less than 20%of the conditioned floor area(CFA);othenvise Section 405 must be used for compliance. <br /> Exception: Additions of 600 square feet(56 m2)or less may have a maximum glass to CFA of 50 percent. <br /> (3)R-values are for insulation material only as appiied in accordance with manufacturers'installation insVUCtions.For mass walis,the"interior of wall°requirement must be <br /> met except if at least 50%of the R-6 insulation required for the°exterior of wall"is installed exterior of,or integral to,the wall. <br /> (4)Ducts&AHU instailed substantially leak free per Section 40322.1.Test by Class 1 BERS rater required. <br /> Exception:Ducts installed onto an existing air distribution system as part of an addition or renovaiion;duct must be R-6 installed per Sec.503.2.7.2. <br /> (5)For all conventional units with capacities greater than 30,000 Btu/hr. For other types of equipment,see Tables 503.2.3(1-8). <br /> Exception:The prohibition on electric resistance heat does not apply to additions,renwations and new heating systems installed in existing buildings. <br /> (6)For other elecVic storage volumes,minimum EF=0.97-(0.00132 x volume). <br /> (7)For other natural gas storage volumes,minimum EF=0.67-(0.0019 x volume). <br /> TABLE402B MANDATORYREQUIREMENTS <br /> COMPONENTS SECTION REQUIREMENTS <br /> To be caulked,gasketed,weathersiripped or ofherwise seeled.Recessed lighting IGrated as meeting ASTM E CHECK <br /> Air leakage 402.4 283.Windows and doors=0.30 cfm/sq.ft.Testing or visual Ins ection re uired.Fire laces: <br /> outdoor combustion air. P q P gasketed da�rs& / <br /> Ceilin s/knee walls ✓ <br /> 9 4052.7 R-19 spece permitting. <br /> Programmabie thermostet 403.1.1 Where forced-air fumece is primary system,progremmeble thertrwstat is required. <br /> Air disMbutian system 4032 Ducts in attics or on roots insulated to R-8;other ducts R-6.Ducts tested to Q,�0.03 by e Class 7 BERS reter. <br /> Water heaters Heat trap required for verticai pipe risers.Comply with efficiencies In Table 403.4.32.Provide switch or c�early <br /> 403.4 merked cfrcuit breaker(electric)or shutoff(ges).Circuleting system pipes ineuleted to=R-2+eccessible manual <br /> OFF switch, <br /> Swimmin P 3Pes erW M1eated pools must have vepor-reterdant covers or a Iiquid cover or other means proven to reduce heat <br /> g pool&s es 403.9 loss except R 70%of heet hom site-recoveretl energy.Off/tlmer awitch required.Gas heaters minimum thertnal <br /> efficien =78% 82°,6 atter 4/16/13.Heet um ol heeters minimum COP=4.0. <br /> Coolin/heatin S�yng calculetion performetl&attached.Minimum etficienGes per Tables 5032.3.Equipment efficiency verification <br /> 9 g equipment 403.6 required.Special occasion cooling or heating cepacity requlres separate system or variable capaciry system. <br /> Electric heet>70kW must 6e divided into two or more sta es. <br /> Lighting equipment 404.1 At least 50%of pertnenently installed IighGng fixtures shall be high-efficacy lamps. <br /> 2010 FLORIDA BUILDING CODE—ENERGY CONSERVATION <br /> C.5 <br />