My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
12-13367
Zephyrhills
>
Building Department
>
Permits
>
2012
>
12-13367
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2013 10:38:52 AM
Creation date
7/2/2013 10:38:50 AM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYR COMMONS
Building Department - Doc Type
Permit
Permit #
12-13367
Building Department - Name
SF ZEPHYR COMMONS LP
Address
7920 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project:Humana Zephyrhills <br /> Title:Humana Zephyrhills <br /> Type:Office <br /> (WEA File:FL_TAMPA_INTERNATIONAL_AP.tm3) <br /> Other Required Compliance <br /> Category Section Requirement(write N/A in box if not applicable) Check <br /> Report 506.4.2 Input Report Print-Out from EnergyGauge F1aCom attached � <br /> Operations Manual 303.3.1, Operations manual provided to owner � <br /> 503.2.9.3, <br /> 505.7.4.2 <br /> Windows&Doors 502.3.2 Glazed swinging entrance&revolving doors:max. 1 0 cfrn/ftZ;all NA <br /> other products:0.3 cfm/82 <br /> Joints/Cracks 502.3.3 To be caulked,gasketed,weather-stripped or otherwise sealed NA <br /> Dropped Ceiling Cavity 502.3 Vented:seal&insulated ceiling.Unvented seal&insulate�roof& NA <br /> side walls <br /> HVAC Efficiency 503.2.3 Minimum efficiencies:Tables 503.2.3(1)-(8) NA <br /> HVAC Controls 503.2.4 Zone controls prevent reheat(exceptions);separate thermostatic NA <br /> control per zone; <br /> Ventilation 503.2.5 Outdoor air supply&exhaust ducts shall have dampers that � <br /> automatically shut when systems or spaces served are not in use. <br /> Exhaust air energy recovery required for cooling systems <br /> (Exceptions). <br /> ADS 503.2.7.5 Duct sizing and Design have been performed � <br /> HVAC Ducts 503.2.7 Air ducts,fittings,mechanical equipment&plenum chambers shall � <br /> be mechanically attached,sealed,insulated&installed per Table <br /> 503.2.7.2.Fan power limitations. <br /> Balancing 503.2.9.1 HVAC distribution system(s)tested&balanced.Report in� � <br /> construction documents. <br /> Piping Insulation 503.2.8 HAC and service hot water.In accordance with Table 503.2.8. � <br /> Water Heaters 504 Performance requirements in accordance with Table 504.2.Heat � <br /> trap required. <br /> Swimming Pools 504.7 Vapor-retazdant or liquid cover or other means proven to reduce NA <br /> heat loss on heated pools;Time switch(exceptions);readiky <br /> accessible on/off switch. <br /> Motors 505.7.5 Motor efficiency criteria have been met NA <br /> Lighting Controls 505.2,502.3 Automatic control required for interior lighti�g in building,s>5,000 � <br /> s.f.,Space control,Exterior photo sensor;Tandom wiring with I or <br /> 3 linear fluorescent lamps>30W <br /> EnergyGauge Summit�Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 <br /> 7/27/2012 Page 7 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.