Laserfiche WebLink
NOTE1 <br />Subscript at strobes and speaker /strobes denotes candela based on NFPA 72 (1996) and UL 1971, <br />SYMBOL <br />FACP <br />FAAP <br />FAT( <br />P'NR <br />15th Ave. <br />POWER EXPANDER PANEL <br />F—F] <br />MANUAL STATION <br />EXISTING MANUAL STATION <br />7 <br />HEAT DETECTOR <br />❑s <br />SMOKE DETECTOR <br />0 <br />© <br />DUCT SMOKE DETECTOR -- <br />PLENUM SMOKE DETECTOR <br />la <br />a <br />DH <br />cF GENERATOR FAULT <br />48' TO TOP OF BOX - DEEP 1900 W/ SINGLE GANG GS <br />DEVICE RING OR OLD WORK BOX <br />8B BOX OR SINGLE GANG BOX <br />8B BOX OR SINGLE GANG BOX 0 <br />SEE INSTALLATION INSTRUCTIONS O <br />1900 BOX, 88 BOX OR SINGLE GANG BOX <br />GENERATOR START <br />KITCHEN HOOD <br />COMPUTER ROOM SYSTEM <br />SPRINKLER FLOW <br />VALVE TAMPER <br />REMOTE INDICATOR LIGHT SINGLE GANG BOX MOUNTED IN ACCESSIBLE AREA <br />MONITOR <br />MODULE <br />(SINGLE ZONE) <br />LOCATED AT AN ACCESSIBLE LOCATION NEAR DEVICE <br />SERVED - DEEP 1900 BOX <br />- <br />SERVED DEEP 1900 BOX <br />STROBE <br />DEEP 1900 BOX OR TWO GANG OLD WORK BOX, MOUNTED SO <br />THAT THE ENTIRE LENS IS BETWEEN 80' - 96' A,FF <br />MONITOR <br />MODULE <br />(TWO ZONES) <br />LOCATED AT AN ACCESSIBLE LOCATION NEAR DEVICE <br />SERVED - DEEP 1900 BOX <br />DEEP 1900 BOX WITH 1 1/2' EXTENSION RING <br />HORN / STROBE <br />DEEP 1900 BOX OR TWO GANG OLD WORK BOX, MOUNTED SO <br />THAT THE ENTIRE LENS IS BETWEEN 80' - 96' AFF <br />CONTROL MODULE <br />RELAY MODULE <br />DOOR HOLDER <br />® FIRE PUMP RUN <br />© FIRE PUMP FAULT <br />KN07X FIRE DEPARTMENT KNOX BOX <br />- -__ — <br />LOCATED AT AN ACCESSIBLE LOCATION NEAR DEVICE <br />HORN <br />DEEP 1900 BOX OR TWO GANG OLD WORK BOX, MOUNTED SO <br />THAT THE TOP OF THE DEVICE IS NOT LESS THAN 90' A,F.F. <br />- <br />SERVED DEEP 1900 BOX <br />- AND NOT - LESS -_THAN 6'- BELOW - THE_ INISHED CEILING <br />ACCESSIBLE AND WITHIN 3 FEET OF DEVICE SERVED <br />O <br />SPEAKER <br />DEEP 1900 BOX WITH 1 1/2' EXTENSION RING <br />- DEEP 1900 BOX <br />� <br />SPEAKER / STROBE <br />DEEP 1900 BOX WITH 1 1/2' EXTENSION RING <br />D <br />FIREFIGHTERS PHONE <br />— <br />0 <br />JUNCTION BOX <br />ANN <br />ANNUNCIATOR <br />01 20 <br />5 <br />;o <br />1 <br />1 <br />C <br />�C <br />• <br />L <br />a <br />Q �7 <br />r� <br /><; <br />� f 3 <br />N <br />ct <br />�>, n <br />r <br />I Issue Date: 7/12/12 1 <br />Revisions <br />No, I Date , Description <br />MGQ & Associates, Inc. <br />1719 E. Columbus Drive <br />Tampa, FL, 33605 <br />Tel (813) 877 -8895 Fax; (813) 877 -8777 <br />Project Number: Drawn By: P.J, <br />Designed By: MGQ & ASSOCIATES, INC. <br />Bright Beginnings Day Care <br />60/ 38112 15th Ave, <br />Zephryhills, FL. 33542 <br />Sheet Number. <br />F -1 <br />