My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
12-13441
Zephyrhills
>
Building Department
>
Permits
>
2012
>
12-13441
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2013 10:39:35 AM
Creation date
7/18/2013 10:39:33 AM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYR COMMONS
Building Department - Doc Type
Permit
Permit #
12-13441
Building Department - Name
SF ZEPHYR COMMONS LP
Address
7920 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
df-60379:A1 •E-400 <br /> CRF-3oo(A) . ��•��Te�A�arms <br /> � <br /> Relay Module by H o n eywe I I <br /> , _ <br /> General <br /> The CRF-300(A)Addressabie Relay Module provides the sys- <br /> tem with a dry-contact eutput for activating a va�iety of auxil- ' <br /> iary devices, such as fans, door holders, dampers, control '� ' i7 <br /> equipment, etc. Addressability allows the dry contact to be <br /> activated through panel programming,on a select basis. ,,, <br /> LiteSpeed'TM is a communication protocol developed by "'"" <br /> Fre•Lite Engineering that greatly enhances the speed of com- �`^� ���� <br /> munication between analog intelligent devices. Intelligent �,.;,, <br /> devices communicate in a grouped fashion. If one of the ��5 <br /> devices within the group has new information, the panel CPU "�, � "`"`" <br /> stops the group poli and concentrates on single points. The »a=��„�„�„�^"w„���� <br /> � <br /> .��.,K.......... <br /> net e ect is response speed greater than five times that of q, „ <br /> other designs. <br /> ..,.� <br /> w�, .�.; <br /> Features <br /> • Built-in type identification automatically identifies these <br /> 8 <br /> devices to the control panel. <br /> • Internal circuitry and relay powered directly by two-wire ° <br /> SLC loop. <br /> • Integral LED "blinks" green each time a communication is CRF-300(A) <br /> received trom the control panel and turns on in steady red <br /> when activated. <br /> • High noise immunity(EMF/RFI) <br /> • Wide viewing angle of LED <br /> • SEMS screws with clamping plates for wiring ease Specifications <br /> • Direct-dial entry of address:01—159 for MS-960�(A)series Normal operating vottage: 15 to 32 VDC. <br /> panels,01 —99 on MS-9200UDLS(A)and MS-9050UD(A). Maximum SLC current draw: 6.5 mA(LED on) <br /> Appiications Average operating current: 230 NA direct poll (CLIP mode), <br /> 255 NA group poil(LiteSpeed mode)with LED flashing. <br /> The CRF-300(A) may be programmed to operate dry contacts EOL resistance: not used. <br /> for door holders,Air Handling Unit shutdown,etc.,and to reset <br /> four-wire smoke detector power. Temperature range: 32°F to 120°F(0°C to 49°C). <br /> Humidity range: 10%to 93%non-condensing. <br /> Construetion Dimensions: 4.5' (11 43 cm) high x 4' (10 16 cm) wide x <br /> • The face plate is made of off-white heat-resistant plastic. �•25' (3.175 cm) deep. Mounts to a 4' (10 16 cm) square x <br /> • Controls include two rotary switches for direct-dial entry of 2•�25'(5.398 mm)deep box. <br /> address setting. <br /> • The CRF-300(A)is configured for a single Class B(Style Y) Relay Contact Ratings <br /> or Class A(Style Z)Notification Appliance Circuit. <br /> • The CRF-300(A) provides two Form-C dry contacts that Load Description Application Maximum Current <br /> switch together <br /> Voltage Rating <br /> Resistive Non-Coded 30 VDC 3.0 A <br /> Operation Resistive Coded 30 VDC 2.0 A <br /> Each CRF-300(A)uses one of the addresses on a SLC loop. it Resistive Non-Coded 110 VDC 0.9 A <br /> responds to regular polls from the control panel and reports its Resistive Non-Coded 125 VAC 0.9 A <br /> type and status, including the open/normal/short status of its <br /> Notification Appliance Circuit(NAC) The LED blinks with each Inductive(UR=Sms) Coded 30 VDC 0.5 A <br /> poll received. On command, it activates its internal relay. Inductive(UR=2ms) Coded 3o VDC 1.0 A <br /> NOTE:Open/short supervrsion is suspended with the CRF-300. Inductive(PF=0.35) Non-Coded 125 VAC 0.5 A <br /> Rotary switches set a unique address for each module. The <br /> address may be set before or after mounting. The built-in <br /> TYPE CODE (not settable)wili identify the module to the con- <br /> trol panei, so as to differentiate between a control module and <br /> a relay module. <br /> df-60379:A1•OB/04l09—Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.