My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
12-13446
Zephyrhills
>
Building Department
>
Permits
>
2012
>
12-13446
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2013 10:45:07 AM
Creation date
7/18/2013 10:45:03 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
12-13446
Building Department - Name
QUIROS MARTINEZ,ELIAS
Address
5411 TANGERINE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Subsidence lm+estigation SDII Project Number:3023547 <br /> Quiros-Martiriez Residence-Zephyrhills,Florida <br /> 4.0 CONCLUSIONS <br /> It is SDII's opinion, with a reasonable professional probability, that sinkhole activity as <br /> defined by Fj627.706 Florida Statutes exists at the Quiros-Martinez residence. Evidence of <br /> sinkhole actiwity was identified at the site, including: (1) the systematic pattern of declining N <br /> values throu��h clay-rich soils overlying limestone in SAT borings B-1 and B-2; (2) multiple feet <br /> of weight-of-rod/hammer strength materials overlying limestone in SPT barings B-1 and B-2; <br /> and(3)the ra,pid losses of drilling fluid circulation above limestone in SPT borings B-1 and B-2. <br /> Furthermor�:�, based on the data presented herein, it is SDII's opinion, with a reasonable <br /> professional probability,that a sinkhole loss,as described by§627J06 Florida Statutes, has <br /> occurred at trhe Quiros-Marfinez residence. The damage to the residence is consistent with <br /> normal shrinls:age cracking of un-reinforced or mildly reinforced concrete and masonry; minor <br /> differential fc,undation movement associated with sinkhole activity; long-term deflection of the <br /> roof structure„ post-construction structural settlement; and minor thermal and moisture induced <br /> volume chan�es of construction materials including gypsum board, wood trim and framing, <br /> stucco, and f,��steners. The lack of sufficient footing embedment may have contributed to the <br /> damage. The observed damage on the exterior and interior of the residence is cosmetic in nature, <br /> such that the design function of the building has not been compromised. <br /> SDII recomm��nds that the sinkhole conditions be remediated using compaction grout injection to <br /> increase the dc;nsity of the soils and cap the limestone. Following the compaction grouting, 5DII <br /> recommends tl5at the shallow soils around the perimeter of the residence be stabilized through a <br /> program of vertical chemical grout injection. SDll also recommends that the rernediation <br /> program be monitored in order to verify that it is completed in accordance with our <br /> recommendations. The cost of remediation, monitoring, and certification is estimated to be <br /> approximately $59,275. <br /> 4-1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.