My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
12-13485
Zephyrhills
>
Building Department
>
Permits
>
2012
>
12-13485
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2013 11:16:06 AM
Creation date
7/18/2013 11:16:05 AM
Metadata
Fields
Template:
Building Department
Company Name
SUNSET ESTATES
Building Department - Doc Type
Permit
Permit #
12-13485
Building Department - Name
REID,DANIEL & RUTH
Address
39443 8TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�.�.W�,�,�. Project Summary J�• Un�012 <br /> Enfrre Nouse �: �cn� <br /> Affordable Air Solutions, Inc. <br /> easz w.6s c�en�h.w se see.a rampe,Fl.aaasa W,aw:e�s-s�6-zr53 F�uc:esb6ss-9s28 �+,elt:�oa�dai�g�n.a.00m w.ix�sort.ew..oa�+uxMS:cac�e4esse <br /> � � • • <br /> For: Daniel Reid,Muw Unit Home <br /> 38443 8th Ave.,Zephyrhi4ls,FL 33542 <br /> Notes: <br /> � • • • <br /> Weather: Tampa,FL,US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 41 °F Outside db 91 °F <br /> Inside db 70 °F Inslde db 75 °F <br /> Design TD 29 °F Design lU 16 °F <br /> Delly range L <br /> Retative humidiry 70 % <br /> Moisture difference 29 g�flb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> StruCture 19170 Btuh StruCture 20154 Btuh <br /> Ducts 0 Btuh Ducts 0 �tuh <br /> Ce�tral veM(0 dm) 0 Btuh Central veM(0 cTm) 0 Btuh <br /> HumEdifiCation 0 Btuh Blower 0 Btutt <br /> Piping 0 Btuh <br /> Equipment load 19170 Btuh Use msnufacturer's date y <br /> Ratelswing mulGplier 1.00 <br /> Infiltration Equipment sensible loed 20154 Btuh <br /> Method Simpl'�fied Latent Cooling Equipment Load Sizing <br /> Construction quafity Average <br /> Flreplaces o StrucWre 1455 Stuh <br /> Du�ts 0 Btuh <br /> Heating Cooling CeMreil vent(0 cfm) 0 Btuh <br /> Area(ft=) 1406 1400 Equipmern latent load 1455 Btuh <br /> �blume(tN) 112D0 11200 <br /> Air changeslhour 0.45 0,23 Equipment total load 216t 0 Btuh <br /> Equiv.AVF(cfm) 84 43 Req,total capscity at 0.70 SHR 2.4 ton <br /> Heating Equipmet�t Summary Cooling Equipment Summary <br /> Make Make Goodman <br /> Trade Trade Unit 1 of 2 <br /> Model Cond <br /> AHRI ref Coil <br /> AHRI ref <br /> Efhciency 0 AFUE Eificiency 13 SEER <br /> Heatlng input 0 MBtuh Sensible cooling 0 Btuh <br /> Heating output 0 Btuh Latent cooiing 0 Btuh <br /> Temperature nse 0 °F Total c�oiing 0 Btuh <br /> Actual air flow 916 cfm Actual alr flow 916 cTm <br /> Air flow faCtor 0.048 cfmlBtuh Air flow factor 0.045 Gfm/Btuh <br /> Static pressure 0 in H20 Static pressure 0 in N20 <br /> Space thennostat I.oad sensible heat ratio 0.93 <br /> Calculations approved by ACCA to meet all requirements of Menual J 8th Ed. <br /> ���X7�•� Rlght$uiteW UnN6rai1201212.0.13 RigM J�Mpbila �l112�Sap�z{OE;�3:04 <br /> Pa9e 1 <br /> C:IWINOOW5ITEMPIwslmpl9e�lb63-{693.WS0-9348-2Mace5E9d7d.rvp Ca1cqMJB F�qdDOOrlaces; S <br />
The URL can be used to link to this page
Your browser does not support the video tag.