My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
12-13539
Zephyrhills
>
Building Department
>
Permits
>
2012
>
12-13539
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/22/2013 10:19:11 AM
Creation date
7/22/2013 10:19:10 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVER OAKS
Building Department - Doc Type
Permit
Permit #
12-13539
Building Department - Name
OWENS,MITCH
Address
37149 CULLENS TRL
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Pro ect Summa�V J�b� <br /> lA/1•1 h�$��• � •� Date: 10/16/2012 <br /> � Entire House By: ACE AIR CONDITIONING... <br /> ACE AIR CONDITIONING & ELECTRIC <br /> 923 W.MEMORIAL BLVD,LAKELAND,FL 33815 Phone:863-688-2238 Fax:863686-9798 License:CAC039755 <br /> � f ' � • <br /> For MITCH OWENS <br /> 37149 CULLENS TRAIL,ZEPHYRHILLS, FL 33542 <br /> Phone:863-559-6130 <br /> Notes. <br /> ! - • • • <br /> Weather� Tampa, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 41 °F Outside db 91 °F <br /> Inside db 70 °F Inside db 75 °F <br /> Design TD 29 °F Design TD 16 °F <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 56 gr/Ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 26091 Btuh Structure 18043 Btuh <br /> Ducts 4730 Btuh Ducts 5914 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 30820 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1 00 <br /> Infiltration Equipment sensible load 23957 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Average <br /> Fireplaces 0 Structure 2508 Btuh <br /> Ducts 1655 Btuh <br /> Heating Cooling Central vent(0 cfm) 0 Btuh <br /> Area(ft� 1675 1675 Equipment latent load 4163 Btuh <br /> Volume(ft� 15075 15075 <br /> Air changes/hour 0.38 0.20 Equipment total load 28120 Btuh <br /> Equiv AVF(cfm) 95 50 Req.total capacity at 0 70 SHR 2.9 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Make <br /> Trade Trade <br /> Model Cond <br /> AHRI ref Coil <br /> AHRI ref <br /> Efficiency 0 HSPF Efficiency 13 SEER <br /> Heating input Sensible cooling 25200 Btuh <br /> Heating output 0 Btuh @47°F Latent cooling 10800 Btuh <br /> Temperature rise 0 °F Total cooling 36000 Btuh <br /> Actual air flow 1010 cfm Actual air flow 1010 cfm <br /> Air flow factor 0 033 cfm/Btuh Air flow factor 0.042 cfm/Btuh <br /> Static pressure 0 in H20 Static pressure 0 in H20 <br /> Space thermostat Load sensible heat ratio 0 85 <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> � wri htsoft° 2oi2-o�c-is�s:os:os <br /> � Right-Suite�Universa12012 12.0.13 Right J�Mobde Page 1 <br /> �� C:\WINDOWS\TEMP�wstmp\93422a68-ba45-4c4a-b934-df9689a1441e.rup CaIc=MJB FrontDoorfaces: S <br />
The URL can be used to link to this page
Your browser does not support the video tag.