Laserfiche WebLink
10;59'38a.m. 05 11-2012 4/5 <br /> 352-498-7852 <br /> � JT <br /> l <br /> T'orcc Fn�inee�in�;�: Te�tinb TI1C. <br /> iy5ib Rsvuhlc�rt�ud llrire <br /> kiuniblc,'C7i 77338 <br /> Code Compliance: 7he praduct descri6ed herein has demonstrated complian�e with <br /> The Florida 6uilding Code 2010,Section 1504.3.2,1504.7. <br /> Evaluation ReportScope: The product evaluatfon is limited to compllance with the structural wind load <br /> requirements of the Florida 8uilding Code 2010,as relates ta Rule 9N-3. <br /> Perfarmance Standards: The product described herein has demonstrated compliance with: <br /> a UL 580-06-Test for Uplift Resistance of Roof Assemblies <br /> ■ UL 1897-04-Uplift Test For Roof Covering Systems <br /> ■ FM 4471,Sectfon 5.4-Foot Traffic Resistan�e Test <br /> Reference Data: 1. UL 580-94/1897-96 UptiftTest <br /> Force Engineering&Testing,Inc.(F8C Organlzation�TS'F-5328) <br /> Report No.117-004D7T-�9,Oated 11/16/09 <br /> 2. FM 4471-95,Sectian 5.4 Foot Traffic Resistance Test <br /> Force Engineering&Testing,(nc.(FBC Organlzation#TST-5328) <br /> Report No.117-0238T-09E,Dated 07J21/2009 <br /> 3. Certificate af Independence <br /> By Terrence E.Walfe,P.E.(No,44923)@ Force[ngineering&Testing,Inc. <br /> (FBC Organfzation#t ANE ID:1920) <br /> Test Standard Equivalency: 1. The UL 56D-94 test standard(s equivalent ta the UL 580-06 test standard. <br /> 2. The UL 1897-98 test standard is equlva{ent tathe UL 1897-04 test standard. <br /> quallty l�ssuran�e Entity: The manufarturer has established�ompllance of roof panel products in <br /> accordance with the Florida Building Code and Rule 9N-3.005(3)for <br /> manuFac[uring under a quality assurance program audited by an approved <br /> quality assurance entity. <br /> Minimum Slope Range: Minimum Slope shali comply with Fiorida Building Code 2010,including Section <br /> 1507.A.2 and in accardance with Manufacturers recommendations. For slopes <br /> iess than 3:12,lap sealant must be used in the panel side laps. <br /> installation: Install per manufacturer's recommended detaifs. <br /> UnderlaymenY: Per Manufacturer's installation guidelines per Florida Building Code 201D 5ection <br /> 15�7.4.5. <br /> ',���1t�11111I��I <br /> `�� ��i C E,E,. �y �fs - <br /> ,, 0 � <br /> .�� Q`��. , �E N 5��'"�% <br /> �' � � '. No.4i9,i� ��,)� �;7' <br /> = ' ' �(��-!;�e—'� <br /> �7 ,,,� .k��--� ,�Ir� 3 <br /> �` �"�- `?7'E'�"�-- ' :% <br /> � q' STA7E OF ;a� <br /> � <br /> '���` AZ 0 RI 4�`, ��: <br /> se.w orttmf, �i FS•• ••V'4�+, <br /> i� !'r�����Il1S�a```` <br /> FL#31651.27 Rl F�bruarv 22. 2012 <br />