My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
12-13561
Zephyrhills
>
Building Department
>
Permits
>
2012
>
12-13561
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/22/2013 10:42:04 AM
Creation date
7/22/2013 10:42:03 AM
Metadata
Fields
Template:
Building Department
Company Name
MOORES FIRST ADDITION
Building Department - Doc Type
Permit
Permit #
12-13561
Building Department - Name
HANNAN,ANDREA LEE
Address
38738 SOUTH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� • <br /> DANSCO � Product Manufacturer: <br /> ENGINEERING,LLC ; M@t3I SySte'fY1S IC1C. <br /> P.O.BOX 3400 <br /> �1z F«��� � 3301 Paul Buchman H1NY <br /> Apolb 6each,FL 33572 <br /> : Plant City, FL 33585 <br /> Samuel0.Greenberg,pE ' <br /> � Product Description: <br /> lrvnn J 8eriso�,PE : 26 Ga., 36° Coverage, $/." Tall Rib, non-structural metal roof panei over min. 15/32° <br /> • Plywood. <br /> �,H.H,��h.PE : panel Roiiformer. MRS Metal Rollforming Systems <br /> 13906 N. Newport HWY <br /> Adarsh 6.Shah,PE <br /> Mead, Washington 99021 <br /> Compliance Statement: <br /> The product as described in this report has demonstrated compliance with the Florida <br /> Building Code 2010, Sections 1504.3.2. <br /> Documentation Supporting the Compliance Statement: <br /> The product has been tested in accordance with: <br /> � UL 580/UL 1897 by Force Engineering &Testing <br /> • TAS 125 <br /> • Test Report 129-0475T-08B& 129-0475T-08C <br /> A) Fastener Spacing at 24°O.C. <br /> B) Fastener Spacing at 12°O.C. <br /> Limitations and Conditions of use for NON-HVHZ: <br /> Maximum Roof Component Uplift Pressure: 144.58 psf (ultimate wind pressure) <br /> @ 2'-0"" O.C. Fastener Spacing <br /> 243.33 psf (ultimate wind pressure) <br /> @ 1'-0"" O.C. Fastener Spacing <br /> Panel Material Standards: 26 Ga., 0.0185°Thick material Grade 80. <br /> Panel Material shafl comply with FBC 2010, <br /> Section 1507.4.3 <br /> Panel Clip Fasteners: #10-16/8 HWH Woodgrip @ 24" O.C. @ 9"-9"-9"-9" <br /> Fastener Pattem min. '/." Penetration into <br /> plywood. #9-15 HWH Woodgrip @ 12" O.C. @ 6.5"- <br /> 2.5"-6.5"-2.5"� 5"-2.5"-6.5„ <br /> Fastener Pattern min. <br /> Panel Side laps shall be fastened together. <br /> w/ 1/4-14 x 7/8" Lap Tek w/sealer washer @ <br /> 24°O.C. Fasteners must be Corrosion <br /> resistance per FBC 2010, Section 1507.4. <br /> p 813 645.0166 � f.81 3 645 9698 � ww�v danscoengineering com <br />
The URL can be used to link to this page
Your browser does not support the video tag.