<br /> System 1, Zone 1 Summary Loads (Avera e Load Procedure for Rooms)
<br /> �:>
<br /> �, �;
<br /> 2A-m-d:Glazing-Double pane low-e (e =0.60),sliding 414 0 0 � 21,594 21,594
<br /> glass door, metal frame no break, u-value 0.84,
<br /> SHGC 0.61 �
<br /> 11 D• Door-Wood - Solid Core 21 0 0 254 254
<br /> 12E-Obw:Wall-Frame, R-19 insulation in 2 x 6 stud cavity, 861 0 0 961 961
<br /> no board insulation, brick finish,wood studs
<br /> I 16A-13: Roof/Ceiling-Under Attic with Insulation on Attic 1323 0 0 6,946 6,946
<br /> Floor(also use for Knee Walls and Partition Ceilings),
<br /> Unvented Attic, No Radiant Barrier,Any Roofing
<br /> Material,Any Roof Color, R-13 insulation
<br /> 22G5p1-t: Floor-Slab on grade, Horizontal board 144 0 0 0 p I
<br /> insulation extends 4'under slab,tile covering, R-5
<br /> insulation, passive, light dry soil
<br /> Subtotals for structure 0 0 29,755 29,755
<br /> i People: 2 400 460 860
<br /> � Equipment: 0 1,200 1,200
<br /> Lighting: 100 341 341
<br /> Ductwork. 0 0 3,006 3,006
<br /> , Infiltration•Winter CFM•0, Summer CFM:0 0 0 0 0 ,
<br /> I System 1,Zone 1 Load Totals. 0 400 34,762 35,162 �
<br /> . . . ,_.. >�;y�,• �Rk¢;.�,�''F`�s�;;, ,�i,#,�;, .� ..:wAr . ' %t ..a„- _ _y, .
<br /> ' •:�- ",_ , •;...,.�� ' _ �ti .,::,�.�` . :.
<br /> Supply CFM: :1,581 V,u '-4;�CFM Pe�r`Square 7ft.: �, ��= 1.195 *
<br /> I Square ft. of Room Area: 1,323 Square ft. Per Ton: q52
<br /> ' Volume (ft3) of Cond. Space: (clg.) 11,907 I
<br /> ' Based on area of rooms being heated or cooled (whichever governs system) rather than entire floor area.
<br /> :����;;�ii#,�±y.�����i's.'„iiL.,�''�f:�_I•:t3,.�ir'7::t'7�- .. -xE,�g , .� _ . _ _
<br /> . � : �.. ` , , ... .4� `1^,��„ a.;"'s.�.�.;, `u .. s�c'° q - . .^��:�,d'<:'.�+aw � ' , �"`r.4�.`.., .,i,i�{. '{s.!,`,.y„�y "�. ��,
<br /> i aTotal Sensible Gain: o ' �' '
<br /> 34,762 Btuh 99 /o
<br /> Total Latent Gain. 400 Btuh 1 %
<br /> Total Cooling Required: 35,162 Btuh 2.93 Tons(Based On Sensible+ Latent)
<br /> � `"c _ `4�.,� ,'���e4�;�u' l;i-..�^;,'c`%•.'L.7-�� ^:x.a.wpa�.+`ay.,.����e a','`,,'„,',.e"sY�,-.w. . °.�,,; .
<br /> . . o. , ,� r .a . ,. _
<br /> ° . .a^,..:. . . ' . . ..�,..,e„ ,. . ,
<br /> ..� ;.,,:.' ;:; .,,;��:.�f,,�-.,«,:..'`:.�'�.
<br /> IRhvac is an ACCA approved Manual J and Manual D computer program i
<br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
<br /> Atl computed results are estimates as building use and weather may vary.
<br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
<br /> iyour design conditions.